Coding level 1
Group 2 "Boiler"
(cont.)
Coding in the delivered condition
Service interval in months
23:0
No time set for burner service in-
terval
Service status
24:0
Display does not show
Group 3 "DHW"
Coding
Coding in the delivered condition
Cylinder heating control type
55:0
Cylinder heating
hysteresis
Set DHW temperature reheating suppression
67:40
For solar DHW heating:
Set DHW temperature 40 °C.
Above the selected set tempera-
ture reheating is suppressed
(DHW heating by the boiler is
blocked).
Group 4 "Solar"
Only in conjunction with solar control module, type
SM1.
Coding
Coding in the delivered condition
Speed control solar circuit pump
02:...
Data dependent on the software
version of solar control module
SM1
Maximum cylinder temperature
08:60
The solar circuit pump is switched
off when the actual DHW tempera-
ture reaches the maximum cylinder
temperature (60 °C).
32
2.5 K
±
Possible change
23:1
Interval adjustable from 1 to
to
24 months.
23:24
24:1
Display shows
set automatically and must be reset
manually after a service.
Possible change
55:1
Adaptive cylinder heating (see
page 64)
67:0
Set DHW temperature adjustable
to
from 0 to 90 °C (limited by boiler-
67:90
specific parameters).
Possible change
02:0
Solar circuit pump is not speed-con-
trolled
02:1
With wave packet control function
Never adjust
02:2
Solar circuit pump is speed-control-
led with PWM control
08:10
Set DHW temperature adjustable
to
from 10 to 90 °C.
08:90
. The address is