DANGER
・Never use this product in locations where flammable gas or ignitable substances are present.
INSTALLATION WARNING
・When installing, ensure that work is done in accordance with the instruction manual. When installation is improper, there is
risk of electric shock and fire.
・Installation shall be done by Service personnel with necessary and appropriate technical training and experience. There is a
risk of electric shock and fire.
・Do not cover the product with cloth or paper etc. Do not place anything flammable around. This might cause damage,
electric shock or fire.
WARNING on USE
・Do not touch this product or its internal components while circuit in operation, or shortly after shutdown. You may receive a
burn.
・While this product is operating, keep your hands and face away from it as you may be injured by an unexpected situation.
・For products with no cover, do not touch them as there are high-voltage and high temperature parts inside. Touching them
might cause injury such as electric shock or burn.
・There are cases where high voltage charge remains inside the product. Therefore, do not touch even if they are not in
operation as you might get injured due to high voltage and high temperature. You might also get electric shock or burn.
・Do not make unauthorized changes to this product nor remove the cover as you might get an electric shock or might damage
the product. We will not be held responsible after the product has been modified, changed or dis-assembled.
・Do not use this product under unusual condition such as emission of smoke or abnormal smell and sound etc. Please stop
using it immediately and shut off the product. It might lead to fire and electric shock. In such cases, please contact us. Do
not attempt repair by yourself, as it is dangerous for the user.
・Do not operate and store these products in environments where condensation occurs due to moisture and humidity. It might
lead fire and electric shock.
・Do not drop or apply shock to this product. It might cause failure. Do not operate these products mechanical stress is
applied.
・When necessary, this products is to be repaired only by us or our authorized agents. It is important that this product cannot
be used in hazardous environments (facilities such as nuclear power control system or life support equipment) without our
written consent.
CAUTION on MOUNTING
・Confirm connections to input/output terminals are correct as indicated in the instruction manual before switching on.
・Input voltage, Output current, Output power, ambient temperature and ambient humidity should be kept within
specifications, otherwise the product will be damaged.
・Input line, please use the wires as short and thick as possible.
・Do not use this product in special environment with strong electromagnetic field, corrosive gas or conductive substances
and direct sunlight, or places where product is exposed to water or rain.
・Mount this product properly in accordance with the instruction manual, mounting direction and shall be properly ventilated.
・Please shut down the input when connecting input and output of the product.
・When installing in environment where conductive foreign, dust and liquid may be present, please consider penetration of
above foreign material in the power supply by installing filter, to prevent trouble or malfunction.
・Please check the connector is locked securely, and be careful the harness does not come off the connector after connecting.
ZWS300RC Series
Instruction Manual
1/17
<Page>
TDK-Lambda
Series
ZWS300RC
INSTRUCTION MANUAL
A284-04-01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZWS300RC Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TDK-Lambda ZWS300RC Series

  • Page 1 TDK-Lambda Series ZWS300RC INSTRUCTION MANUAL ZWS300RC Series Instruction Manual BEFORE USING THE PRODUCT Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product. Incorrect usage could lead to an electrical shock, damage to the product or a fire hazard.
  • Page 2: Caution On Use

    TDK-Lambda Series ZWS300RC INSTRUCTION MANUAL CAUTION on USE ・Product individual notes are shown in the instruction manual. If there is any difference with common notes individual notes shall have priority. ・Before using this product, be sure to read the catalog and instruction manual. There is risk of electric shock or damage to the product or fire due to improper use.
  • Page 3 TDK-Lambda Series ZWS300RC INSTRUCTION MANUAL Note ・Take note that traces of sheet metal processing be left in our power supplies. ・When disposing product, follow disposal laws of each municipality. ・Published EMI (CE, RE) or immunity is the result when measured in our standard measurement conditions and might not satisfy specification when mounted and wired inside end-user equipment.
  • Page 4 TDK-Lambda Series ZWS300RC INSTRUCTION MANUAL 1. Model name identification method ZWS 300 RC – 24 / □ (*1) ZWS300RC options Blank : Standard Option (*1) : With remote ON/OFF control model. /BM : Model for connect ZBM-AC. Rated Output Voltage /RBM: With remote ON/OFF control model.
  • Page 5: Block Diagram

    TDK-Lambda Series ZWS300RC INSTRUCTION MANUAL 3. Block Diagram Input Output 85~265VAC Circuit Photo- Circuit coupler Sensing Photo- Output coupler Sensing Remote Photo- ON/OFF coupler Control *Option model “/R” *Option model ” ” •Circuit topology, switching frequency Switching Circuit : Cascade forward topology 130kHz  PFHC circuit : Active filter 50kHz-70kHz (Spread)
  • Page 6: Sequence Time Chart

    TDK-Lambda Series ZWS300RC INSTRUCTION MANUAL 4. Sequence time chart Input Voltage OVP point (*2) Vout Output Voltage Remote ON/OFF Control +R & -R Level (*1) (*1) Target option : /R   +R & -R Level      Higher than 4.5V : Output on     Lower than 0.8V : Output off...
  • Page 7 TDK-Lambda Series ZWS300RC INSTRUCTION MANUAL 5. Terminal Connection method Pay attention to the input wiring. If it is connected to wrong terminal, the product will be damaged. Input must be off when making connections. • Please insert or remove CN2 after the internal voltage drop enough. (More than 3 min after input turn off) CN2 is connected to an internal capacitor, and high voltage remains even if the input turn off.
  • Page 8: Inrush Current

    TDK-Lambda Series ZWS300RC INSTRUCTION MANUAL 6. Explanation of Functions and Precautions 6-1. Input Voltage Range Input voltage range is single phase 85-265VAC (47-63Hz) or 120-370VDC. Input voltage, which is out of specification, might lead the product damage. For cases where conformance to various safeties required, described as 100-240VAC (50-60Hz). Output derating is required for input voltage less than 90VAC or less than 127VDC.
  • Page 9: Series Operation

    TDK-Lambda Series ZWS300RC INSTRUCTION MANUAL 6-6. Output Ripple & Noise The specified maximum ripple & noise value is measured according to below measurement circuit. When load lines are longer, ripple will becomes larger. In this case, electrolytic capacitor, film capacitor, etc. might be necessary to be used across the load terminal.
  • Page 10: Parallel Operation

    TDK-Lambda Series ZWS300RC INSTRUCTION MANUAL 6-8. Parallel Operation (A) Operation to increase the output current is not possible. (B) Operation as a Backup System Connect our reverse prevention module "RP-60-20" or ORing-diode to the output side of the product. (1) Adjust each product output to same voltage. (The difference of each product output voltage should be within ±5%.)
  • Page 11 TDK-Lambda Series ZWS300RC INSTRUCTION MANUAL 6-10. Withstand Voltage The product is designed to withstand 3.0kVAC between input and output, 2.0kVAC between input and terminal and 500VAC between output and terminal each for 1 minute. When testing withstand voltage, set current limit of withstand voltage test equipment at 10mA (Output - terminal : 20mA).
  • Page 12 TDK-Lambda Series ZWS300RC INSTRUCTION MANUAL 6-12. Connecting method of Buffer module ZBM-AC (Option “/BM”) By connecting our ZBM-AC to CN2, the Hold up time of ZWS300RC can be extended. Derating the output power of ZWS300RC by 10W per ZBM-AC connection.
  • Page 13 TDK-Lambda Series ZWS300RC INSTRUCTION MANUAL 7. Mounting Method 7-1. Mounting Direction The standard mounting is direction (A). Possible mounting directions are (A), (B),(C), (D) and (E). Do not mount the product in any other directions. Do not exceed the derating of maximum load, which is limited by mounting direction and ambient temperature.
  • Page 14 TDK-Lambda Series ZWS300RC INSTRUCTION MANUAL ■ Convection Cooling (170<Vin<265VAC or 240<Vin<370VDC) MOUNTING A MOUNTING B MOUNTING C MOUNTING D MOUNTING E Load (%) Ta (°C) MOUNTING A MOUNTING B MOUNTING C MOUNTING D MOUNTING E -10 - +20 ■ Forced Air Cooling MOUNTING A-E (Air velocity >...
  • Page 15: Mounting Method

    TDK-Lambda Series ZWS300RC INSTRUCTION MANUAL 7-3. Output Derating according to the Input Voltage Load (%) is percent of maximum output current value in a rated output voltage. Input AC Input Voltage Load (%) (VAC) 90-265 Input DC Input Voltage Load (%)
  • Page 16: Wiring Method

    TDK-Lambda Series ZWS300RC INSTRUCTION MANUAL (2) Condition to meet Isolation & Withstand Voltage standard keep 4mm space from the top and sides of power supply. And keep 8mm space from the solder surface of PCB. More than More than Component side must be connected to the Protective earth terminal of the equipment.
  • Page 17: Warranty Period

    TDK-Lambda Series ZWS300RC INSTRUCTION MANUAL 9. The life expectancy The life of the power supply depends on the life of the built-in aluminum electrolytic capacitor. The life is described in reliability data. The life of the aluminum electrolytic capacitor varies depending on the method of mounting the power supply, the load current, and the ambient temperature.

This manual is also suitable for:

Zws 300 rc-24

Table of Contents