Download Print this page
Pentair Hydromatic C4H X P Series Installation And Operation Manual

Pentair Hydromatic C4H X P Series Installation And Operation Manual

Submersible solids handling pump

Advertisement

Quick Links

SUBMERSIBLE SOLIDS HANDLING PUMP
C4H(X*)P, H4Q(X*)P, S4K(X*)P, S4L(X*)P, S4LV(X*)P, S4B(X*)
P, S6L(X*)P, S6A(X*)P, S8F(X*)P
(* USED IN HAZARDOUS LOCATIONS CLASS I, DIVISION I, GROUPS C & D): FM
INSTALLATION AND
OPERATION MANUAL
pentair.com
©2021. All Rights Reserved.

Advertisement

loading
Need help?

Need help?

Do you have a question about the Hydromatic C4H X P Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Pentair Hydromatic C4H X P Series

  • Page 1 SUBMERSIBLE SOLIDS HANDLING PUMP C4H(X*)P, H4Q(X*)P, S4K(X*)P, S4L(X*)P, S4LV(X*)P, S4B(X*) P, S6L(X*)P, S6A(X*)P, S8F(X*)P (* USED IN HAZARDOUS LOCATIONS CLASS I, DIVISION I, GROUPS C & D): FM INSTALLATION AND OPERATION MANUAL pentair.com ©2021. All Rights Reserved.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Safety Information ....................................3 General Information ....................................4 Pump Installation ...................................... 5 Pump Operation & Maintenance ................................6 Troubleshooting ....................................... 7 Parts List ........................................8 Wiring Diagrams ......................................15 Warranty ........................................16...
  • Page 3: Safety Information

    SAFETY INFORMATION READ AND FOLLOW SAFETY INSTRUCTIONS! This product is used in conjunction with a This is the safety alert symbol. When you see this symbol system containing a tank under pressure, which may over time on your pump or in this manual, look for one of the following corrode, weaken and burst or explode, causing serious or fatal signal words and be alert to the potential for personal injury: personal injury, leaking or flooding and/or property damage.
  • Page 4: General Information

    GENERAL INFORMATION Once the sensor resets, the starter is automatically reset for FM This manual contains important information for the safe use of for continued operation of the pump. This circuitry is supplied in a this product. Read completely and do not throw away. Hydromatic control panel.The sensors are set to trip at 130°C.
  • Page 5: Pump Installation

    INSTALLATION & OPERATIONS INSTALLING PUMP IN SUMP For record keeping purposes, we suggest the pump be marked Before installing the pump in the sump, lay it on its side and rotate externally with the new voltage and qualified personnel that impeller.
  • Page 6: Pump Operation & Maintenance

    INSTALLATION & OPERATIONS PUMP OPERATIONS STARTING SYSTEM service or repaired at an authorized Pentair Hydromatic service center. Charges will not be allowed if (in warranty) pump is not Double check all wire connections. taken to an authorized Pentair Hydromatic service center. When Turn pumps to Off position on H-O-A switches.
  • Page 7: Troubleshooting

    TROUBLESHOOTING PUMP OPERATES WITH SELECTOR SWITCH IN HAND POSITION PUMP TROUBLESHOOTING BUT WILL NOT OPERATE IN AUTO POSITION. Below is a list of common problems and the probable causes: This indicates trouble in the float level control or the PUMP WILL NOT START. alternator relay.
  • Page 8: Parts List

    PARTS INDEX C4H(X)P, H4Q(X)P, S4K(X)P, S4L(X)P, S4LV(X)P, S4B(X)P, S6L(X)P, S6A(X)P AND S8F(X)P For use with product built with Premium Efficient motor. 3, 4 250 FRAME PUMPS 280 FRAME PUMPS - DISCONTINUED, FOR REFERENCE ONLY Ref. Part No. Part Description Qty. Ref.
  • Page 9 PARTS INDEX H4Q(X)P S4K(X)P S4L(X)P S4LV(X)P S4B(X)P S6L(X)P S6A(X)P S8F(X)P C4H(X)P D3, D6, D15 - Not shown in this view Item Description S4L(X)P S4B(X)P S4K(X)P S4LV(X)P H4Q(X)P S6L(X)P S6A(X)P S8F(X)P C4H(X)P IMPELLER 025940002 136920012 137200012 110430002 151510012 025940002 136940052 025940002 153590002 O-RING 05876A178...
  • Page 10 MOTOR PARTS GROUP 250 FRAME PUMPS MOTOR PARTS GROUP 40 HP 40 HP 30 HP 30 HP 30 HP 20 – 25 HP 20 – 25 HP 20 – 25 HP ITEM 4-POLE 1750 RPM 460/3/60 575/3/60 230/3/60 460/3/60 575/3/60 208-230/3/60 460/3/60 575/3/60...
  • Page 11 IMPELLER PARTS LIST 250 FRAME PUMPS IMPELLER PARTS LIST H4Q(X)P S4K(X)P CAT. NO. VOLT/PH CORD TRIM IMPELLER CAT. NO. VOLT/PH CORD TRIM IMPELLER 1750 RPM 1750 RPM H4Q(X)P2000DC 208/3 151510062 S4K(X)P2000DC 208/3 9.25 137200122 S4K(X)P2000EC 230/3 9.25 137200122 H4Q(X)P2000EC 230/3 151510062 S4K(X)P2000FC 460/3...
  • Page 12 MOTOR PARTS GROUP 250 FRAME PUMPS IMPELLER PARTS LIST S4L(X)P S6L(X)P CAT. NO. VOLT/PH CORD TRIM IMPELLER Cat. No. Volt/Ph Cord Trim Impeller 1750 RPM 1750 RPM S4L(X)P2000DC 208/3 9.88 025940372 S6L(X)P2000DC 208/3 9.88 025940372 S4L(X)P2000EC 230/3 9.88 025940372 S6L(X)P2000EC 230/3 9.88 025940372...
  • Page 13 IMPELLER PARTS LIST 250 FRAME PUMPS IMPELLER PARTS LIST S8F(X)P S6A(X)P Cat. No. Volt/Ph Cord Trim Impeller CAT. NO. VOLT/PH CORD TRIM IMPELLER 1750 RPM 1750 RPM S8F(X)P2000DC 208/3 9.63 025940302 S6A(X)P2500DC 208/3 136940132 S8F(X)P2000EC 230/3 9.63 025940302 S6A(X)P2500EC 230/3 136940132 S8F(X)P2000FC 460/3...
  • Page 14 IMPELLER PARTS LIST 280 FRAME PUMPS IMPELLER PARTS LIST - DISCONTINUED, FOR REFERENCE ONLY S4L(X)P S4LV(X)P CAT. NO. VOLT/PH CORD TRIM IMPELLER CAT. NO. VOLT/PH CORD TRIM IMPELLER 1750 RPM 1750 RPM S4L(X)P5000FC 460/3 11.63 025940002 S4LV(X)P5000FC 460/3 110430002 S4L(X)P5000GC 575/3 11.63 025940002...
  • Page 15: Wiring Diagrams

    WIRING DIAGRAM E-03-558 (08-01-21)
  • Page 16: Warranty

    PH: 800-363-7867 All indicated Pentair trademarks and logos are property of Pentair. Third party registered and unregistered trademarks and logos are the property of their respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer.