Siemens SIMATIC NET RUGGEDCOM RS416F Installation Manual page 51

Table of Contents

Advertisement

Certification
6.2 EMC and Environmental Type Tests
Environmental Type Tests
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60068-2-6
IEC 60068-2-27
42
Description
Test
Cold Temperature
Dry Heat
Humidity (Damp
Heat, Cyclic)
DC Power ports
AC Power ports
Description
Test Ad
Test Bd
Test Db
Vibration
Shock
Test Levels
1.5 kV
2 kV
Test Levels
Severity Levels
-40 °C (-40
°F), 16 Hours
85 °C (185
°F), 16 Hours
95% (non-
condensing), 55 °C
(131 °F), 96 hours
2 g @ 10-150 Hz
30 g @ 11 ms
Installation Manual, 04/2021, C79000-G8976-1354-04
 
 
 
Class 2
Class 2
RUGGEDCOM RS416F

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SIMATIC NET RUGGEDCOM RS416F and is the answer not in the manual?

Questions and answers

Table of Contents