The individual selection options are explained in detail below:
Blue LED
Setting for the time (minutes) after which the blue "Battery Cold" indicator should light up
to indicate that the battery is sufficiently cooled down. The set value is the time from the
end of charging.
In conjunction with the "Temperature-controlled charging" option, it is possible to set a
temperature value from which the blue "Battery Cold" indicator should light up to indicate
that the battery is sufficiently cooled down.
external start/stop
The following settings are available for external start/stop:
Button
-
Normal
-
-
-
-
44
The function of the "Pause/Start" button can be simulated by means of an external
button.
Start ON:
Charging starts when an external switch is closed and a battery is detected
or when the charging plug is connected by closing the auxiliary contacts and a bat-
tery is detected.
Start OFF:
Charging starts when a battery is connected.
Stop ON:
Charging is interrupted when an external switch is opened
or when the charging plug is disconnected by opening the auxiliary contacts.
Stop OFF:
The opening of an external switch or the auxiliary contacts is ignored.