Section B: Startup diagnostics

In this section
"Startup diagnostic codes" (page 25)
"Startup sequence description" (page 28)
"Troubleshooting startup problems" (page 30)

Startup diagnostic codes

HEX display diagnostic codes are divided into the following two categories:
Critical startup diagnostic codes
All critical startup diagnostics must pass before the 202i can proceed
with the start sequence. If a critical diagnostic fails, the start sequence
indefinitely halts, an error code displays, and you here a continuous beep.
The following table shows the critical startup diagnostic codes with their
corresponding failure codes. Failure of these diagnostics means that there
has been a server failure. The start cycle halts.
Test code
T:01
T:02
T:03
T:04
T:05
T:06
T:07
Copyright © 2009, Nortel Networks
.
critical startup diagnostics
non critical operating system and switch diagnostics
Note: When a test succeeds, the next test code appears.
Test description
Internal RAM self-test
ALU self-test
Address mode self-test
Boot ROM self-test
Timer self-test
Watchdog self-test
EEPROM self-test
Nortel CallPilot
202i Server Maintenance and Diagnostics
NN44200-708 01.02 Standard
5.0 11 August 2009
Startup diagnostic codes 25
Failure code
F:01
F:02
F:03
F:04
F:05
F:06
F:07