FISCHER MS11 Instruction Manual

FISCHER MS11 Instruction Manual

Contact pressure gauge

Advertisement

Quick Links

Instruction Manual
MS11 Contact Pressure Gauge

Table of Contents

1.
Safety Instructions
2.
3.
4.
5.
Commissioning
6.
7.
8.
9.
12. Dimensions
13. Ordering Code
14. CE-Certificate
1.
Safety Instructions
1.1.
General
personnel responsible for the equipment must
read this thoroughly before attempting to install or
operate this equipment. A copy of this manual
must always be kept accessible at the place of
work for reference by concerned personnel.
Chapter 1 (sections 1.2 through 1.7) contains ge-
neral as well as specific safety instructions. Chap-
ters 2 through 10, covering topics ranging from
intended purpose of the equipment to its final dis-
posal, also include important points relating to
safety. Overlooking or ignoring any of these safety
points can endanger humans and animals, and
possibly cause damage to other equipment.
1.2.
Personnel Qualification
Personnel responsible for installation, operation,
maintenance and inspection of this product must
have the qualifications, training and experience
necessary to carry out such work on this type of
equipment.
This manual contains detailed
information about the product,
and instructions for its installati-
on, operation and maintenance.
Operators and other technical
1.3.
Risks of Disregarding Safety Instruc-
tions
Disregarding safety instructions, use of this pro-
duct for purposes for which it is not intended, and/
or operation of this product outside the limits spe-
cified for any of its technical parameters, can result
in harm to persons, the environment, or the plant
on which it is installed. Fischer Mess- und Regel-
technik GmbH will not be responsible for conse-
quences in such circumstances.
1.4.
Safety Instructions for Operators
Safety instructions for the proper use of this pro-
duct must be followed. This information must be
available at all times to by personnel responsible
for installation, operation, maintenance and in-
spection of this product. Adequate steps must be
taken to prevent the occurrence of hazardous con-
ditions that can be caused by electric energy and
the convertible energy of the process media. Such
conditions can, for example, be the result of impro-
per electrical or process connections. Detailed in-
formation is available in relevant published norms
(DIN EN, UVW in Germany; and equivalents in
other countries), industrial standards
such as DVWG, Ex-, GL-, VDE guide-
lines, as well as regulations of the local
authorities (e.g., EVUs in Germany).

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MS11 and is the answer not in the manual?

Questions and answers

Summary of Contents for FISCHER MS11

  • Page 1: Table Of Contents

    Operators and other technical on which it is installed. Fischer Mess- und Regel- personnel responsible for the equipment must technik GmbH will not be responsible for conse- read this thoroughly before attempting to install or quences in such circumstances.
  • Page 2: Intended Applications

    Any modifications to this product, if and as necessary, In non-operative state, forces of springs on both sides of should be done only by Fischer Mess- und Regeltechnik diaphragm are balanced. Pressure or differential pressu- GmbH.
  • Page 3 • Make electrical connections to the instrument through For Gaseous Media a suitable fuse. Capilliary reactive coil MZ400 Commissioning Power supply and signal cabling to the instrument must be correctly selected to meet operational requirements, and installed in a way that does not cause physical stress to the instrument.
  • Page 4: Transport

    Any defective devices or devices with missing parts However, to ensure reliable operation and maximize the should be retourned to Fischer Mess- und Regeltechnik operating life of the instrument, it is recommended that GmbH. For quick service contact our service department.
  • Page 5: Specifications

    11. Specifications General Measuring range 0 ... 400 mbar up to 0 ... 25 bar (s. Ordering Code) Nominal pressure 25 bar Max. pressure overpressure proof to nominal pressure (all measuring ranges), safe against negative pressure Perm. ambient temperature -10 ... +70°C Perm.
  • Page 6 M16x1.5 plastic Standard connection rear connection shank connection shank per DIN EN 837 M16x1.5 plastic MS11 connection Wall mounting connection shank per DIN EN 837 MS11 Panel mounting Electrical connections cable terminal box or 7-pole plug connection M20x1.5 cable connection...
  • Page 7 13. Ordering Code Contact Pressure Gauge MS11 Measuring Range 0 . . . 400 mbar ............... > 0 . . . 0.6 bar ............... > 0 . . . bar ............... > 0 . . . 1.6 bar ............... >...
  • Page 8 Technische Änderungen vorbehalten • Subject to change without notice • Changements techniques sous réserve Fischer Mess- und Regeltechnik GmbH • Bielefelder Str. 37a • D-32107 Bad Salzuflen • Tel. +49 5222 9740 • Fax +49 5222 7170 eMail: info@fischermesstechnik.de • www.fischermesstechnik.de...

Table of Contents