Data Sheet and Operating Manual
ME01
Digital manometer
ME01 ## # 87 # HL R####
Gas explosion protection zone 2
Table of Contents
1

Safety guidelines

2
3
4
5
6
7
8
9
1
Safety guidelines
1.1
General Information
This operating manual contains instruc-
tions fundamental to the installation, op-
eration and maintenance of the device
that must be observed unconditionally. It
must be read by the assembler, operator and the
specialized personnel in charge of the instrument
before it is installed and put into operation. This op-
erating manual must always be accessible at the
place of installation.
The subsequent sections on general safety instruc-
tions 1.2 - 1.7 as well as the following special in-
structions ranging from intended use to disposal 2-
10 contain important safety instructions the non-
observance of which can cause danger to persons,
animal and physical objects.
1.2
Personnel Qualification
The instrument may only be installed and commis-
sioned by specialized personnel familiar with the in-
stallation, commissioning and operation of this
product.
Specialized personnel are persons who can assess
the work they have been assigned and recognize
potential dangers by virtue of their specialized train-
ing, their skills and experience and their knowledge
of the pertinent standards.
For explosion-proof models the specialized person-
nel must have received special training or instruc-
tion or be authorized to work with explosion-proof
instruments in explosion hazard areas.
1.3
Risks due to Non-Observance of Safe-
ty Instructions
Non-observance of these safety instructions, the in-
tended use of the device or the limit values given in
the technical specifications can be hazardous or
cause harm to persons, the environment or the
plant itself. The supplier of the equipment will not be
liable for damage claims if this should happen.
1.4
Safety Instructions for the Operating
Company and the Operator
The safety instructions governing correct operation
of the instrument must be observed. The operating
company must make them available to the installa-
tion, maintenance, inspection and operating per-
sonnel. Dangers arising from electrical components,
energy discharged by the medium, escaping medi-
um and incorrect installation of the instrument must
be eliminated. The particulars can be
found in the respective regulations
such as DIN, EN, explosion hazard,

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ME01 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FISCHER ME01 Series

  • Page 1 d e v e l o p i n g s o l u t i o n s Data Sheet and Operating Manual ME01 Digital manometer ME01 ## # 87 # HL R#### Gas explosion protection zone 2 Table of Contents Safety guidelines Application purpose Product and function description...
  • Page 2: Safety Guidelines

    Any modifica- as 'Electrical equipment for use in areas with com- tions/alterations required will be carried out by bustible gases', zone 2. Fischer Mess- und Regeltechnik GmbH only. Designation as per guideline 2014/34/EU Impermissible modes of operation ...
  • Page 3: Installation And Assembly

    Wiring diagram Installation and assembly Do not take out the connecting plug As standard, the device with the connecting port for while energized connection to pipes and other connection parts, such as the welding sleeve, union nut with soldering and welding nipples, is equipped with soldering and Three-conductor circuit welding nipples (see data sheet MZ...).
  • Page 4: Maintenance

    Maintenance Service The instrument is maintenance-free. All defective or faulty devices should be sent direct- ly to our repair department. We would ask you to We recommend checking the instrument at regular please coordinate all return shipments with our intervals to ensure reliable operation and a long sales department so that we can ensure careful service life.
  • Page 5: Technical Data

    11 Technical Data Measuring range in bar 0-1.6 0-2.5 0-10 0-16 0-25 0-40 0-60 Overpressure-proof in bar Measuring range in bar - 1..0 -1..0.6 -1..1.5 -1..3 -1..5 -1..9 -1..15 0...-1 Overpressure-proof in bar -10°C  60°C Permissible ambient temperature Admissible medium temperature Max.
  • Page 6: Dimensional Drawings

    12 Dimensional drawings (all dimensions in mm unless otherwise specified) M16 x 1.5 SW22 Manometer connection port G1/2 nach DIN EN 837...
  • Page 7 13 Order Codes Digital manometer Type ME01 R#### Measuring range 0 ... 1 bar ..........> 0 2 0 ...1.6 bar ..........> 0 3 0 ...2.5 bar ..........> 0 4 0 ... 4 bar ..........> 0 5 0 ...
  • Page 8: Attachments

    Technische Änderungen vorbehalten • Subject to change without notice • Changements techniques sous réserve Fischer Mess- und Regeltechnik GmbH • Bielefelder Str. 37a • D-32107 Bad Salzuflen • Tel. +49 5222 9740 • Fax +49 5222 7170 • eMail: info@fischermesstechnik.de • www.fischermesstechnik.de...

Table of Contents