FISCHER MS10 Instruction Manual

Contact pressure vacuum gauge
Hide thumbs Also See for MS10:

Advertisement

Quick Links

Instruction Manual
MS10 Contact Pressure Vacuum Gauge
Table of Contents
1.
Safety Instructions
2.
Intended Applications
3.
Product Description and Functions
4.
Installation
5.
Commissioning
6.
Maintenance
7.
Transport
8.
Service
9.
Accessories
10. Disposal
11. Specifications
12. Dimensions
13. Ordering Code
14. Declaration of Conformity
1.
Safety Instructions
1.1.
General
personnel responsible for the equipment must read
this thoroughly before attempting to install or opera-
te this equipment. A copy of this manual must
always be kept accessible at the place of work for
reference by concerned personnel.
Chapter 1 (sections 1.2 through 1.7) contains gene-
ral as well as specific safety instructions. Chapters
2 through 10, covering topics ranging from intended
purpose of the equipment to its final disposal, also
include important points relating to safety. Overloo-
king or ignoring any of these safety points can
endanger humans and animals, and possibly cause
damage to other equipment.
This manual contains detailed
information about the product
and instructions for its installa-
tion, operation and maintenance.
Operators and other technical
1.2.
Personnel Qualification
Personnel responsible for installation, operation,
maintenance and inspection of this product must
have the qualifications, training and experience
necessary to carry out such work on this type of
equipment.
1.3.
Risks of Disregarding Safety Instruc-
tions
Disregarding safety instructions, use of this product
for purposes for which it is not intended, and/or ope-
ration of this product outside the limits specified for
any of its technical parameters, can result in harm to
persons, the environment, or the plant on which it is
installed. Fischer Mess- und Regeltechnik GmbH
will not be responsible for consequences in such
circumstances.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MS10 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FISCHER MS10

  • Page 1 Instruction Manual MS10 Contact Pressure Vacuum Gauge Table of Contents Safety Instructions Intended Applications Product Description and Functions Installation Commissioning Maintenance Transport Service Accessories 10. Disposal 11. Specifications 12. Dimensions 13. Ordering Code 14. Declaration of Conformity Safety Instructions 1.2.
  • Page 2: Product Description And Functions

    / maintenance of the product. 1. Measuring diaphragm Any modifications to this product, if and as necessary, 2. Motion work 3. Tappet should be done only by Fischer Mess- und Regeltechnik 4. Micro switches, GmbH. Operating elements 5. Pressure chamber 1.6.
  • Page 3 4.1. Process Connection 5.2. Adjustment of Zero Point • Only qualified technicians authorized for this type of • Vent pressure lines to atmosphere. work should undertake installation. • Remove cover. • Only for intended mechanical process connection. • Set measuring indicator to zero by zero point adjust- •...
  • Page 4: Maintenance

    Service Any defective devices or devices with missing parts should be returned to Fischer Mess- und Regeltechnik GmbH. For quick service contact our service department. Remaining medium in and on dismantled measuring instruments may cause danger to persons, environment and equipment.
  • Page 5: Specifications

    11. Specifications General Measuring range (s. Ordering Code) Nominal pressure 25 bar Max. pressure overpressure proof to nominal pressure (all measuring ranges), vacuum proof up to fine vacuum 10 mbar   10 m³/s Leakage rate   10 mbar Perm.
  • Page 6: Dimensions

    12. Dimensions (all units in mm unless otherwise stated) cable terminal box M16 x 1.5 plastic connection KF10 small flange pipe connection...
  • Page 7: Ordering Code

    13. Ordering Code Contact Pressure Vacuum Gauge MS10 Measuring range -200 . . . 200 mbar..........> B 0 . . . 400 mbar ..........> 8 -1 ..0,6 bar..........> 3 -1 ..1,5 bar..........> 3 -1 .
  • Page 8: 14. Declaration Of Conformity

    Technische Änderungen vorbehalten • Subject to change without notice • Changements techniques sous réserve Fischer Mess- und Regeltechnik GmbH • Bielefelder Str. 37a • D-32107 Bad Salzuflen • Tel. +49 5222 9740 • Fax +49 5222 7170 eMail: info@fischermesstechnik.de • www.fischermesstechnik.de...

Table of Contents