Feig Electronic OBID i-scan ISC.MR200 Manual

Feig Electronic OBID i-scan ISC.MR200 Manual

Standard-reader
Hide thumbs Also See for OBID i-scan ISC.MR200:
Table of Contents

Advertisement

Quick Links

OBID i-scan
final
public (B)
2008-05-26
H40801-5e-ID-B.doc
®
ID ISC.MR200
Standard-Reader
from Firmware-Version 1.12
MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Feig Electronic OBID i-scan ISC.MR200

  • Page 1 ® MANUAL OBID i-scan ID ISC.MR200 Standard-Reader from Firmware-Version 1.12 final public (B) 2008-05-26 H40801-5e-ID-B.doc...
  • Page 2 Composition of the information in this manual has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information.
  • Page 3: Table Of Contents

    3.4.1. Dedicated Input / Output Functions ................32 3.5. CFG3: RF-Interface ......................33 3.6. CFG4: Transponder Parameters..................35 3.7. CFG5: Anticollision......................37 3.8. CFG6 - 9: Reserved ......................39 3.9. CFG10: Trigger ........................40 3.10. CFG11 Read Mode Data....................42 FEIG ELECTRONIC GmbH Page 3 of 144 H40801-5e-ID-B.doc...
  • Page 4 4. Protocols for Reader Configuration 4.1. [0x80] Read Configuration ....................67 4.2. [0x81] Write Configuration ....................68 4.3. [0x82] Save Configuration....................69 4.4. [0x83] Set Default Configuration (Reset) ................70 5. Protocols for Reader Control 5.1. [0x52] Baud Rate Detection....................71 FEIG ELECTRONIC GmbH Page 4 of 144 H40801-5e-ID-B.doc...
  • Page 5 6.1.5. [0x24] Write Multiple Blocks ..................95 6.1.6. [0x25] Select........................97 6.1.7. [0x26] Reset to Ready ....................98 6.1.8. [0x27] Write AFI......................99 6.1.9. [0x28] Lock AFI......................100 6.1.10. [0x29] Write DSFI ....................101 6.1.11. [0x2A] Lock DSFI.....................102 FEIG ELECTRONIC GmbH Page 5 of 144 H40801-5e-ID-B.doc...
  • Page 6 8. Supported ISO15693 Host commands for I-Code EPC Transponders 9. Supported ISO15693 Host commands for I-Code UID Transponders 10. Protocols for Buffered Read Mode 10.1. The Buffered Read Mode Procedure ................130 10.2. Transponder Access in the Buffered Read Mode ............131 FEIG ELECTRONIC GmbH Page 6 of 144 H40801-5e-ID-B.doc...
  • Page 7 ANNEX E: Codes of Reader Types ..................143 ANNEX I: Examples for Read Data ..................144 ISO15693 Host Command (DB-Size of the Transponder = 4 bytes)........144 ISO15693 Host Command (DB-Size of the Transponder = 8 bytes)........144 FEIG ELECTRONIC GmbH Page 7 of 144 H40801-5e-ID-B.doc...
  • Page 8: Revision History Of Documentation

    WLAN Settings Configuration of Scan Mode 09.06.06 Integration of Notification Mode Configuration of Notification Mode 25.09.06 Supported Antenna Multiplexing Configuration of Trigger 04.10.06 Configuration of Reader Login 26.05.08 Configuration of Costumer Parameter FEIG ELECTRONIC GmbH Page 8 of 144 H40801-5e-ID-B.doc...
  • Page 9: Abbreviations

    Most Significant Byte Number Output Read / Write Access Read Relay Radio Frequency RSSI Received Signal Strength Indicator Real Time Clock Table Transponder Timeslot Unique Identifier (read only Serial Number) Write Only Access Write FEIG ELECTRONIC GmbH Page 9 of 144 H40801-5e-ID-B.doc...
  • Page 10: Data Transmission Between Obid I-Scan ® Id Isc.mr200 And Host

    Host (Terminal / PC / ..) Reader → parameter- / control command parameter received and stored / control command processed ← status / error status data ← FEIG ELECTRONIC GmbH Page 10 of 144 H40801-5e-ID-B.doc...
  • Page 11: Iso15693 Host Commands

    Transponder data in Reader field ← → write data to Transponder with UID Transponder with correct UID in antenna field ? ← OK status status = no Transponder in Reader field ← FEIG ELECTRONIC GmbH Page 11 of 144 H40801-5e-ID-B.doc...
  • Page 12 = no Trans- Transponder read ponder data in Reader field ← → write data Transponder in antenna field ? ← OK status status = no Trans- ponder in Reader field ← FEIG ELECTRONIC GmbH Page 12 of 144 H40801-5e-ID-B.doc...
  • Page 13 / status = Transponder read no Transponder data in Reader field ← → write data selected Transponder in antenna field ? ← OK status status = no Transponder in Reader field ← FEIG ELECTRONIC GmbH Page 13 of 144 H40801-5e-ID-B.doc...
  • Page 14: Buffered Read Mode

    OK status status = no valid data ← Note: • Only read operations are available with the Buffered Read Mode. • The Buffered Read Mode is only available if Scan Mode is disabled FEIG ELECTRONIC GmbH Page 14 of 144 H40801-5e-ID-B.doc...
  • Page 15: Notification Mode

    Note: • The MR200-Reader does support only one TCP/IP – Connection at the same time. • The reader hardware version FE556/4 is necessary for using the Notification Mode. FEIG ELECTRONIC GmbH Page 15 of 144 H40801-5e-ID-B.doc...
  • Page 16: Scan Mode

    2 Transponder in detection range UID and data block should be read: UID1 data1 UID2 data2 Com-Prefix (optional) SCAN-LOCK-TIME UID: Serial-Number (fix) time to the next new Transponder reading data: data blocks (free programmable) Separation character (optional) End character (optional) FEIG ELECTRONIC GmbH Page 16 of 144 H40801-5e-ID-B.doc...
  • Page 17 Transponder should be within the detection range of the Reader during this time. • Only read operations are available with the Scan Mode. • Scan Mode is only available if Buffered Read Mode is disabled FEIG ELECTRONIC GmbH Page 17 of 144 H40801-5e-ID-B.doc...
  • Page 18: Interface

    Reader. If you use the TCP/IP protocol please be aware that the data packaged in the TCP/IP frame is trans- ferred with Protocol frame: Advanced Protocol-Length as describe below. FEIG ELECTRONIC GmbH Page 18 of 144 H40801-5e-ID-B.doc...
  • Page 19: Serial Data Format And Protocol Frames

    CRC16 Protocol frame: Advanced Protocol-Length Reader ← Host (6...n-2) CONTROL- COM-ADR (DATA) (0x02) ALENGTH ALENGTH BYTE CRC16 CRC16 Host ← Reader (7...n-2) CONTROL- COM-ADR STATUS (DATA) (0x02) ALENGTH ALENGTH BYTE CRC16 CRC16 FEIG ELECTRONIC GmbH Page 19 of 144 H40801-5e-ID-B.doc...
  • Page 20 Cyclic redundancy check of the protocol bytes from 1 to n-2, as specified by CCITT- CRC16 Polynom: + 1 (0x8408) Start Value: 0xFFFF Direction: Backward see ANNEX D: Index of Status Bytes FEIG ELECTRONIC GmbH Page 20 of 144 H40801-5e-ID-B.doc...
  • Page 21: Crc16 Calculation Algorithm

    /* cnt = number of protocol bytes without CRC */ crc ^= DATA[i]; for (j = 0; j < 8; j++) if (crc & 0x0001) crc = (crc >> 1) ^ CRC_POLYNOM; else crc = (crc >> 1); FEIG ELECTRONIC GmbH Page 21 of 144 H40801-5e-ID-B.doc...
  • Page 22: Configuration Parameters (Cfg)

    Malfunctions may occur if parameters are configured outside their described range or if unspecified parameters have been changed! • A firmware update resets the EEPROM to default settings and the Reader goes into the er- ror status “EE-Init-mode”. FEIG ELECTRONIC GmbH Page 22 of 144 H40801-5e-ID-B.doc...
  • Page 23 Changing of this parame- bytes must not be changed, as ter only becomes effective this may cause faulty operation of after writing / saving this the Reader configuration block EEPROM and a Reader reset FEIG ELECTRONIC GmbH Page 23 of 144 H40801-5e-ID-B.doc...
  • Page 24: Cfg0: Passwords

    The Bit in CFG_NO defines if the access to the configuration block is free or if the use should login to the Reader to get access to the configuration block. b0 ⇒ Access if free b1 ⇒ Access need a login FEIG ELECTRONIC GmbH Page 24 of 144 H40801-5e-ID-B.doc...
  • Page 25 • It is possible to disable the READER-ID with an activation code, if the READER-ID is unknown. The activation code must be ordered by your supplier or FEIG Electronic GmbH. Config Protection By means of Config Protection, the access to the configuration parameters stored within the Reader is protected by a 32-bit password, the "READER-ID".
  • Page 26: Cfg1: Interface

    • Via the COM-Adr 255 in the send protocol, the Reader is able to be addressed at any time. It answers then with the configured address. A reasonableness check is performed by writing this parameter to the Reader. If an error occurs the Reader answers with STATUS = 0x11. FEIG ELECTRONIC GmbH Page 26 of 144 H40801-5e-ID-B.doc...
  • Page 27 Number of Data Bits 8 Data Bits - do not use - A reasonableness check is performed by writing this parameter to the Reader. If an error occurs the Reader answers with STATUS = 0x11. FEIG ELECTRONIC GmbH Page 27 of 144 H40801-5e-ID-B.doc...
  • Page 28 The TR-RESPONSE Time must be < “Block Timeout” in the Host COM-Port settings. SCAN-INTERFACE: Selection of the communication port for Scan-Mode Bit: Function: IF-NO IF-NO: Interface Number b000: RS232 b001: RS485/RS422 b01x: - do not use – b1xx: - do not use - FEIG ELECTRONIC GmbH Page 28 of 144 H40801-5e-ID-B.doc...
  • Page 29 By setting of this bit the Notification Mode can be enabled. (Hardware version FE556/4 is necessary). On (only together with BRM-Mode) The following table lists the bit combinations for the reader modes: Host-Mode Scan Mode Buffered Read Mode Notification Mode FEIG ELECTRONIC GmbH Page 29 of 144 H40801-5e-ID-B.doc...
  • Page 30: Cfg2: Inputs / Outputs General

    Bit: Function: REL frq OUT2 frq OUT1 frq Bit combination flashing frequency b 1 1 1 Hz b 1 0 2 Hz b 0 1 4 Hz b 0 0 8 Hz FEIG ELECTRONIC GmbH Page 30 of 144 H40801-5e-ID-B.doc...
  • Page 31 Note: If the REL-TIME and / or OUT2-TIME is > 0x00 the relay and / or OUT2 will be active if the communication (Inventory) between the reader and the transponder was OK. FEIG ELECTRONIC GmbH Page 31 of 144 H40801-5e-ID-B.doc...
  • Page 32: Dedicated Input / Output Functions

    LED1 (green) and LED2 (red) are blinking alternately if a read error of the EEPROM occurred after power-up or a 5.3. [0x63] CPU Reset command. A firmware update sets the EEPROM to initial state and the LED1 and LED2 are also blinking alternately. FEIG ELECTRONIC GmbH Page 32 of 144 H40801-5e-ID-B.doc...
  • Page 33: Cfg3: Rf-Interface

    Firmware Upgrade” first. For this you have to use the demo program ID ISOStart and the Upgrade Code must be ordered by Feig Electronic. A reasonableness check is performed by writing this parameter to the Reader. If an error occurs the Reader answers with STATUS = [0x11].
  • Page 34 Reader and if the ID ISC.DAT has DC power. disabled enabled A plausibility check is performed by writing this parameter to the Reader. If an error occurs the Reader an- swers with STATUS = [0x11]. FEIG ELECTRONIC GmbH Page 34 of 144 H40801-5e-ID-B.doc...
  • Page 35: Cfg4: Transponder Parameters

    Fast Mode (1 / 4) - do not use - SUB-CARRIER ASK (one sub-carrier) - do not use - DATA-RATE - do not use - high NO-TS 16 timeslots 1 timeslot Disabled Enabled FEIG ELECTRONIC GmbH Page 35 of 144 H40801-5e-ID-B.doc...
  • Page 36 A value of 0x00 will be automatically set to a block size of 4byte. Blocksize: Automatic (If transponder is known) Manuel (As specified in DB-Blocksize) Read Mode: b00: Automatic Mode (If transponder is known) Single Read Multiple Read FEIG ELECTRONIC GmbH Page 36 of 144 H40801-5e-ID-B.doc...
  • Page 37: Cfg5: Anticollision

    MAX-TS must contain the value of the desired timeslot. A reasonableness check is performed by writing this parameter to the Reader. If an error occurs the Reader answers with STATUS = 0x11. FEIG ELECTRONIC GmbH Page 37 of 144 H40801-5e-ID-B.doc...
  • Page 38 Transponders inside of the antenna field. Note: If 1 timeslot is set and the CRC on an I-Code EPC is wrong the serial number will be transferred and the status is set to “[0x02] Data False” FEIG ELECTRONIC GmbH Page 38 of 144 H40801-5e-ID-B.doc...
  • Page 39: Cfg6 - 9: Reserved

    3.8. CFG6 - 9: Reserved The configuration block CFG6 and CFG7-9 are reserved for future use. Byte Contents 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Default Byte Contents 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Default FEIG ELECTRONIC GmbH Page 39 of 144 H40801-5e-ID-B.doc...
  • Page 40: Cfg10: Trigger

    The Valid Time (s. CFG12) is restarted with each Trigger Period and thus not longer than one Trigger Period. Unlimited Valid Time: The Valid Time (s. CFG12) is applicable for more than one Trigger Period. FEIG ELECTRONIC GmbH Page 40 of 144 H40801-5e-ID-B.doc...
  • Page 41 Reader is in operation a rising edge on the input stops the Reader Operation TRIGGER_X-HOLD-TIME: (1 ... 65535 * 100 ms = 100 ms ... 6553,5 sec) The TRIGGER-HOLD-TIME defines the period in which the Reader performs inventory commands and hold the RF Power active. FEIG ELECTRONIC GmbH Page 41 of 144 H40801-5e-ID-B.doc...
  • Page 42: Cfg11 Read Mode Data

    (1-8) where the Transponder has been detected, will be stored if a antenna multiplexer is used. TIMER no internal system timer internal system timer will be active see chapter 5.13. [0x85] Set System Timer for details). FEIG ELECTRONIC GmbH Page 42 of 144 H40801-5e-ID-B.doc...
  • Page 43 D-LGT = 4 Output Data 0x23 0x45 0x67 0x89 A plausibility check is performed by writing this parameter to the Reader. If an error occurs the Reader an- swers with STATUS = [0x11]. FEIG ELECTRONIC GmbH Page 43 of 144 H40801-5e-ID-B.doc...
  • Page 44: Cfg12: Read Mode - Filter

    Serial Number as data source, the ID-DB-ADR will be ignored. TR-ID-DB-N Sets the number of data blocks to be read for Transponder identification. If ID- SOURCE selects the Serial Number as data source, the ID-DBN will be ignored. FEIG ELECTRONIC GmbH Page 44 of 144 H40801-5e-ID-B.doc...
  • Page 45: Cfg13 Scan Mode

    0x30 b0001 0x31 b0010 0x32 b0011 0x33 b0100 0x34 b0101 0x35 b0110 0x36 b0111 0x37 b1000 0x38 b1001 0x39 b1010 0x41 b1011 0x42 b1100 0x43 b1101 0x44 b1110 0x45 b1111 0x46 FEIG ELECTRONIC GmbH Page 45 of 144 H40801-5e-ID-B.doc...
  • Page 46 ‘,‘ ‘;’ CR+LF ASCII CR+LF 0x0D and 0x0A 0x0A 0x0D 0x09 ‘;’ 0x3B ‘,’ 0x2C ‘ ‘ 0x20 USER user defined in SEP-USR none 0x00 Note: Only one option could be selected. FEIG ELECTRONIC GmbH Page 46 of 144 H40801-5e-ID-B.doc...
  • Page 47 HEADER-USR1 + 2 + 3 + 4 Example of scan data: COM- Separation Separation Data- Header END Character Character Character Blocks COM- SEP-CHAR USR1 USR2 USR3 USR4 SEP-CHAR USR1 USR2 USR3 FEIG ELECTRONIC GmbH Page 47 of 144 H40801-5e-ID-B.doc...
  • Page 48: Cfg14: Reserved

    3.13. CFG14: Reserved The configuration block CFG14 is reserved for future use. Byte Contents 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Default Byte Contents 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Default FEIG ELECTRONIC GmbH Page 48 of 144 H40801-5e-ID-B.doc...
  • Page 49: Cfg15: Antenna Multiplexing

    Transponder on the active antenna. If the Transponder communication time on the active antenna exceed the MUX-VALID-TIME- ANT_x the Transponder communication on the active antenna is stopped, and the Reader switches to the next antenna. FEIG ELECTRONIC GmbH Page 49 of 144 H40801-5e-ID-B.doc...
  • Page 50 MUX Hardware) to one of the two inputs. Only one output per input can be active at a time. In Single Mode only one channel is enabled. OUTPUT-CHANNELS: Specifies the number of output channels which are used for the multiplexing. FEIG ELECTRONIC GmbH Page 50 of 144 H40801-5e-ID-B.doc...
  • Page 51: Cfg16: Persistence Reset

    Transponders at the antenna port. Timer ticks = 5ms Maximum timer value = 5ms x 65534[0xFFFE] = 5,46125 min. The value 65535 [0xFFFF] indicates that no persistence reset is performed by the Reader FEIG ELECTRONIC GmbH Page 51 of 144 H40801-5e-ID-B.doc...
  • Page 52: Cfg17-19: Reserved

    3.16. CFG17-19: Reserved The configuration blocks CFG17-19 are reserved for future use. Byte Contents 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Default Byte Contents 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Default FEIG ELECTRONIC GmbH Page 52 of 144 H40801-5e-ID-B.doc...
  • Page 53: Cfg20: Rf-Parameter

    REC_CHN: Defines which receiver parameter. Bit: Function SENSE SENSE: b000: automatic b001: receiver sensitivity low b101: receiver sensitivity high other - do not use - FEIG ELECTRONIC GmbH Page 53 of 144 H40801-5e-ID-B.doc...
  • Page 54: Cfg21: Reserved

    3.18. CFG21: Reserved The configuration block CFG21 is reserved for future use. Byte Contents 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Default Byte Contents 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Default FEIG ELECTRONIC GmbH Page 54 of 144 H40801-5e-ID-B.doc...
  • Page 55: Cfg22 + Cfg23: Selection Mask (Only I-Code Uid And Epc Transponder)

    152 (=0x98) SELECTION MASK: Defines the mask for the selection (MSB first). The selection mask is checked against the memory content on a bit by bit basis. FEIG ELECTRONIC GmbH Page 55 of 144 H40801-5e-ID-B.doc...
  • Page 56 Number of Selection Bits Selection 10 11 12 13 14 15 16 17 18 19 20 ... Bits Selection Mask 0x01 0x02 Only Transponders whose serial numbers begin with "0000 0001 00" return an answer. FEIG ELECTRONIC GmbH Page 56 of 144 H40801-5e-ID-B.doc...
  • Page 57: Cfg24-29: Reserved

    3.20. CFG24-29: Reserved The configuration blocks CFG24-29 are reserved for future use. Byte Contents 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Default Byte Contents 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Default FEIG ELECTRONIC GmbH Page 57 of 144 H40801-5e-ID-B.doc...
  • Page 58: Cfg40: Lan Settings, Part 1 (Not Used For Id Isc.mr200-A / -W)

    Changing of the LAN-Settings in CFG 40-41 is only possible if the reader hardware ver- sion is 556/4 or higher. For older hardware versions the tool “Digi Device Discovery” must be used. The configuration pages CFG40-49 cannot be set to default using the command 0x83 Reset. FEIG ELECTRONIC GmbH Page 58 of 144 H40801-5e-ID-B.doc...
  • Page 59: Cfg41: Lan Settings, Part 2 (Not Used For Id Isc.mr200-A / -W)

    Changing of the LAN-Settings in CFG 40-41 is only possible if the reader hardware ver- sion is 556/4 or higher. For older hardware versions the tool “Digi Device Discovery” must be used. FEIG ELECTRONIC GmbH Page 59 of 144 H40801-5e-ID-B.doc...
  • Page 60: Cfg42: Wlan Settings, Part 1 (Not Used For Id Isc.mr200-A / -E / -Ep)

    CFG 44 (SSID-LEN, SSID) are required. Bit: Function NW-TYPE NW-TYPE: network with Access Point Ad-Hoc (Peer-to-Peer) network Note: The configuration pages CFG40-49 cannot be set to default using the command 0x83 Reset. FEIG ELECTRONIC GmbH Page 60 of 144 H40801-5e-ID-B.doc...
  • Page 61: Cfg43: Wlan Settings, Part 2 (Not Used For Id Isc.mr200-A / -E / -Ep)

    This interval is used when the connection failed. The valid range is 10..75 sec. Note: The configuration pages CFG40-49 cannot be set to default using the command 0x83 Reset. FEIG ELECTRONIC GmbH Page 61 of 144 H40801-5e-ID-B.doc...
  • Page 62: Cfg44 Wlan Security Settings, Part 1 (Not Used For Id Isc.mr200-A / -E / -Ep)

    The impact of the WEB-Encryption depend on settings in CFG45. Thus, both configura- tion blocks should be modified in succession. The configuration pages CFG40-49 cannot be set to default using the command 0x83 Reset. FEIG ELECTRONIC GmbH Page 62 of 144 H40801-5e-ID-B.doc...
  • Page 63: Cfg45 Wlan Security Settings, Part 2 (Not Used For Id Isc.mr200-A / -E / -Ep)

    The impact of the WEB-KEY depend on settings in CFG44. Thus, both configuration blocks should be modified in succession. The configuration pages CFG40-49 cannot be set to default using the command 0x83 Reset. FEIG ELECTRONIC GmbH Page 63 of 144 H40801-5e-ID-B.doc...
  • Page 64: Cfg49: Notification Channel (Not Used For Id Isc.mr200-A)

    Notification must be acknowledged with protocol [0x32] Clear Data Buffer TIME-TRIGGERED-TIME: Defines the cycle time in time-triggered mode. max. time period TIME-TRIGGERED-TIME 0...255 * 1s KEEP-ALIVE: Mode for keep alive notification. Bit: Function FEIG ELECTRONIC GmbH Page 64 of 144 H40801-5e-ID-B.doc...
  • Page 65 LED’s V3 (Input) and V4 (Output) will come on for approx. 1 min. Once the LED’s turn off the LAN Controller initializes the new values approx. 1 min. later. The configuration pages CFG40-49 cannot be set to default using the command 0x83 Reset. FEIG ELECTRONIC GmbH Page 65 of 144 H40801-5e-ID-B.doc...
  • Page 66: Cfg63: Customer Parameter

    3.28. CFG63: Customer Parameter The configuration block CFG63 is used for customer parameter. Byte Contents 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Default Byte Contents 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Default FEIG ELECTRONIC GmbH Page 66 of 144 H40801-5e-ID-B.doc...
  • Page 67: Protocols For Reader Configuration

    14 bytes configuration block read from address CFGn in CFG-ADR. Note: A read configuration from EEPROM with reserved configuration blocks will cause an 0x15 error code. see ANNEX D: Index of Status Bytes see Chapter 3. Configuration Parameters (CFG) FEIG ELECTRONIC GmbH Page 67 of 144 H40801-5e-ID-B.doc...
  • Page 68: 0X81] Write Configuration

    14 bytes configuration block stored in the configuration memory of the Reader at address CFGn. Note: A write configuration to EEPROM with reserved configuration blocks will cause an 0x16 error code. see ANNEX D: Index of Status Bytes see chapter 3. Configuration Parameters (CFG) FEIG ELECTRONIC GmbH Page 68 of 144 H40801-5e-ID-B.doc...
  • Page 69: 0X82] Save Configuration

    4.3. [0x82] Save Configuration • A save configuration to EEPROM with reserved configuration blocks will result in error code 0x16 . see ANNEX D: Index of Status Bytes see chapter 3. Configuration Parameters (CFG) FEIG ELECTRONIC GmbH Page 69 of 144 H40801-5e-ID-B.doc...
  • Page 70: 0X83] Set Default Configuration (Reset)

    RAM and EEPROM Notes: • To save the configuration to non-volatile memory, use 4.3. [0x82] Save Configuration • A set default configuration with reserved configuration blocks will cause an error code. FEIG ELECTRONIC GmbH Page 70 of 144 H40801-5e-ID-B.doc...
  • Page 71: Protocols For Reader Control

    This command is only available if the correct COM-ADR of the Reader is used. (Do not use 0xFF) • Do not flash the DSP-Revision G or greater with Firmwareversion’s less than 1.09. See 5.5. [0x65] Get Software Version FEIG ELECTRONIC GmbH Page 71 of 144 H40801-5e-ID-B.doc...
  • Page 72: 0X63] Cpu Reset

    CRC16 STATUS MODE: Defines the controller which will be reset. MODE Controller 0x00 RF Controller 0x04 LAN/WLAN Controller see ANNEX D: Index of Status Bytes see ANNEX D: Index of Status Bytes FEIG ELECTRONIC GmbH Page 72 of 144 H40801-5e-ID-B.doc...
  • Page 73: 0X65] Get Software Version

    DSP Revision >= Silicon Revision G b10: reserved b11: reserved Note: Do not flash the DSP-Revision G or greater with Firmwareversion’s less than 1.09 see ANNEX D: Index of Status Bytes FEIG ELECTRONIC GmbH Page 73 of 144 H40801-5e-ID-B.doc...
  • Page 74 SW-TYPE: Displays the type / model of the Reader (see: ANNEX E: Codes of Reader Types) TR-TYPE: Displays the Transponders supported by the software. Bit: Function: Bit: Function: I-Code I-Code 15693 FEIG ELECTRONIC GmbH Page 74 of 144 H40801-5e-ID-B.doc...
  • Page 75: 0X66] Get Reader Info

    This Information's are necessary for some firmware updates or firmware upgrades. SW-REV / D-REV / HW-TYPE / SW-TYPE / TR-TYPE: see: 5.5. [0x65] Get Software Version see ANNEX D: Index of Status Bytes see ANNEX D: Index of Status Bytes FEIG ELECTRONIC GmbH Page 75 of 144 H40801-5e-ID-B.doc...
  • Page 76 Indicates which customer firmware is licensed on the Reader. FW_L: Indicates which Firmware version is licensed on the Reader. TR_DRV_L: Indicates which Transponder drivers are licensed on the Reader. FNC_L Indicates which optional functions are licensed on the Reader. FEIG ELECTRONIC GmbH Page 76 of 144 H40801-5e-ID-B.doc...
  • Page 77: 0X69] Rf Reset

    • If BRM-Mode is enable, an RF OFF stops the communication and ISO-Host commands are al- lowed. With a RF ON command the BRM-Mode starts again. see ANNEX D: Index of Status Bytes see ANNEX D: Index of Status Bytes FEIG ELECTRONIC GmbH Page 77 of 144 H40801-5e-ID-B.doc...
  • Page 78: 0X6D] Get Noise Level

    11...12 COM-ADR [0x6D] NOISE-LEVEL CRC16 STATUS NOISE-LEVEL: Byte 5...6 7...8 9...10 NOISE-LEVEL min. NL avg. NL max. NL Value min.NL, avg.NL and max.NL in mV. see ANNEX D: Index of Status Bytes FEIG ELECTRONIC GmbH Page 78 of 144 H40801-5e-ID-B.doc...
  • Page 79: 0X6E] Reader Diagnostic

    Listing of detail information for STATUS = 0x84. DATA: Response for Reader Diagnostic Modes MODE = 0x01: FLAGS A FLAGS B FLAGS A: Bit: Function: > < NOISE RF-HW FLAGS B: Bit: Function: FEIG ELECTRONIC GmbH Page 79 of 144 H40801-5e-ID-B.doc...
  • Page 80 Chn3 Chn4 Chn5 MUX-Status MUX-Status MUX-Status Chn6 Chn7 Chn8 Notes: If the channel has not been selected the status is 0xFF. Further informations to the ID ISC.ANT.MUX see manual “H30701-xde-ID-B.pdf” and “M30201-xde-ID-B.pdf“ FEIG ELECTRONIC GmbH Page 80 of 144 H40801-5e-ID-B.doc...
  • Page 81: 0X71] Set Output

    OUT-TIME has no effect on the status of the output output for OUT-TIME = active output for OUT-TIME = inactive FLASH output for OUT-TIME = with OSF alternating see ANNEX D: Index of Status Bytes FEIG ELECTRONIC GmbH Page 81 of 144 H40801-5e-ID-B.doc...
  • Page 82 In order to reset a continuously active time, OUT-TIME = 1 has to be sent to the Reader, which effects a change to the idle status after 100 ms. • The continuous activation is cancelled after a reset or a power failure. FEIG ELECTRONIC GmbH Page 82 of 144 H40801-5e-ID-B.doc...
  • Page 83: Set Output Examples

    INPUTS: Bit: Function: digital input = inactive digital input = active see ANNEX D: Index of Status Bytes see 3.4. CFG2: Inputs / Outputs general see 3.4. CFG2: Inputs / Outputs general FEIG ELECTRONIC GmbH Page 83 of 144 H40801-5e-ID-B.doc...
  • Page 84: 0X85] Set System Timer

    9...10 COM-ADR [0x86] STATUS TIMER CRC16 TIMER: Byte 7...8 TIMER 0...23 0...59 0...59999 Note: • The internal system timer is not a real-time clock (RTC) and the accuracy cannot be guaran- tied. FEIG ELECTRONIC GmbH Page 84 of 144 H40801-5e-ID-B.doc...
  • Page 85: 0Xa0] Reader-Login

    3.1. CFG0: Passwords. NOTE: • A Reader-Login with wrong READER-ID cause a "Logout". • A "Logout" can be effected via the command 5.3. [0x63] CPU Reset. see ANNEX D: Index of Status Bytes FEIG ELECTRONIC GmbH Page 85 of 144 H40801-5e-ID-B.doc...
  • Page 86: Protocols For Iso15693 Host Commands

    6.1.9. [0x28] Lock AFI √ 6.1.10. [0x29] Write DSFI √ 6.1.11. [0x2A] Lock DSFI √ 6.1.12. [0x2B] Get System Information √ 6.1.13. [0x2C] Get Multiple Block Security Status only Philips I-Code UID FEIG ELECTRONIC GmbH Page 86 of 144 H40801-5e-ID-B.doc...
  • Page 87: 0Xb0] Host Commands For Iso15693 Mandatory And Optional Commands

    RESPONSE-DATA: Command specific response Notes: • Data is only transferred if STATUS = 0x00, 0x83, 0x94, 0x95. • These commands aren’t available if Scan-Mode, Buffered Read Mode, or Notification Mode is active. FEIG ELECTRONIC GmbH Page 87 of 144 H40801-5e-ID-B.doc...
  • Page 88: 0X01] Inventory

    Bit: Function MORE MORE: new Inventory requested more data requested (IF Status 0x94 appears-> more data sets are available) DATA-SETS: Number of Transponder data sets to be transferred in this Reader response. FEIG ELECTRONIC GmbH Page 88 of 144 H40801-5e-ID-B.doc...
  • Page 89 I-Code EPC Transponder type. UID: • For UID Transponder: the 19 Byte Identifier Data (IDD) will be displayed. Identifier Data (IDD): User Data UD CRC 16 (Read/Write) (Read/Write) (ReadOnly) DB 0-11 DB12-13 DB14-18 FEIG ELECTRONIC GmbH Page 89 of 144 H40801-5e-ID-B.doc...
  • Page 90 STATUS Byte 0x94 (More Data) is displayed dependence on the Tag Typ: Tr-Type ISO15693 I-Code EPC 96 I-Code UID amount of Trans- ponder setting status 0x94 > 50 > 38 > 25 (with Advanced Protocol Length) FEIG ELECTRONIC GmbH Page 90 of 144 H40801-5e-ID-B.doc...
  • Page 91: 0X02] Stay Quiet

    This command sets one Transponder to Quiet State. REQUEST-DATA 6-13 0x02 MODE MODE: Bit: Function ADR: b001 addressed UID: Read only UID of the Transponder. Note: • This command is only available for ISO15693Transponders. FEIG ELECTRONIC GmbH Page 91 of 144 H40801-5e-ID-B.doc...
  • Page 92: 0X22] Lock Multiple Blocks

    Number of data blocks to be locked, starting at DB-ADR. The maximum number of DB-N is ISO15693 ERROR: ISO15693 ERROR code of Transponder response. This byte is only available if STATUS = 0x95. DB-ADR-E: Block number where the error occurred. FEIG ELECTRONIC GmbH Page 92 of 144 H40801-5e-ID-B.doc...
  • Page 93: 0X23] Read Multiple Blocks

    The maximum number of DB-N, depend on DB-Size and the interface transmit buffer size TX- BUF. The maximum number of DB-N is: (TX-BUF - 10 )/(DB-Size+1) ISO15693 ERROR: ISO15693 ERROR code of Transponder response. This byte is only available if STATUS = 0x95. FEIG ELECTRONIC GmbH Page 93 of 144 H40801-5e-ID-B.doc...
  • Page 94 • If a Transponder does not support Read Multiple Blocks commands several Read Single Block commands are used for this Transponder. • Only one Transponder can be read in the non-addressed mode. FEIG ELECTRONIC GmbH Page 94 of 144 H40801-5e-ID-B.doc...
  • Page 95: 0X24] Write Multiple Blocks

    Number of bytes of one data block. This value depend on the specification of the Trans- ponder manufacturer, see chapter 7.1. Supported ISO15693 Host commands for ISO15693 Transponders. DB-SIZE must be 1 for the I-CODE EPC Transponder. FEIG ELECTRONIC GmbH Page 95 of 144 H40801-5e-ID-B.doc...
  • Page 96 • A write command on I-Code UID and EPC Transponders can only be performed in the non- addressed mode whereas the block-size (DB-SIZE) must be 1 Byte. • If an I-Code UID and EPC Transponder is already locked, the reader answers with status = [0x03]. FEIG ELECTRONIC GmbH Page 96 of 144 H40801-5e-ID-B.doc...
  • Page 97: 0X25] Select

    Read-only UID of the Transponder. ISO15693 ERROR: ISO15693 ERROR code of Transponder response. This byte is only available if STATUS = 0x95. Note: • This command is only available for ISO15693 Transponders. FEIG ELECTRONIC GmbH Page 97 of 144 H40801-5e-ID-B.doc...
  • Page 98: 0X26] Reset To Ready

    Read-only serial number of the Transponder. The UID is required only in the addressed mode. ISO15693 ERROR: ISO15693 ERROR code of Transponder response. This byte is only available if STATUS = 0x95. Note: • This command is only available for ISO15693 Transponders. FEIG ELECTRONIC GmbH Page 98 of 144 H40801-5e-ID-B.doc...
  • Page 99: 0X27] Write Afi

    Application Family Identifier of the Transponder. ISO15693 ERROR: ISO15693 ERROR code of Transponder response. This byte is only available if STATUS = 0x95. Note: • This command is only available for ISO15693 Transponders. FEIG ELECTRONIC GmbH Page 99 of 144 H40801-5e-ID-B.doc...
  • Page 100: 0X28] Lock Afi

    Read-only serial number of the Transponder. The UID is required only in the addressed mode. ISO15693 ERROR: ISO15693 ERROR code of Transponder response. This byte is only available if STATUS = 0x95. Note: • This command is only available for ISO15693 Transponders. FEIG ELECTRONIC GmbH Page 100 of 144 H40801-5e-ID-B.doc...
  • Page 101: 0X29] Write Dsfi

    Data Storage Format Identifier of the Transponder. ISO15693 ERROR: ISO15693 ERROR code of Transponder response. This byte is only available if STATUS = 0x95. Note: • This command is only available for ISO15693 Transponders. FEIG ELECTRONIC GmbH Page 101 of 144 H40801-5e-ID-B.doc...
  • Page 102: 0X2A] Lock Dsfi

    Read-only serial number of the Transponder. The UID is required only in the addressed mode. ISO15693 ERROR: ISO15693 ERROR code of Transponder response. This byte is only available if STATUS = 0x95. Note: • This command is only available for ISO15693 Transponders. FEIG ELECTRONIC GmbH Page 102 of 144 H40801-5e-ID-B.doc...
  • Page 103: 0X2B] Get System Information

    The LSB (32bits) from the Read only Serial Number of the Transponder. AFI: Application Family Identifier. If not supported by the Transponder, this value will return 0x00. Manufacturer Code: Manufacturer specific code (see: ANNEX A: Codes of Transponder Types) FEIG ELECTRONIC GmbH Page 103 of 144 H40801-5e-ID-B.doc...
  • Page 104 IC reference (version) of the Transponder. If not supported by the Transponder, this value will return 0x00. Chip Version: Chip version of the Transponder Note: This command is only available for ISO15693 Transponders. FEIG ELECTRONIC GmbH Page 104 of 144 H40801-5e-ID-B.doc...
  • Page 105: 0X2C] Get Multiple Block Security Status

    The maximum number of DB-N is 255. ISO15693 ERROR: ISO15693 ERROR code of Transponder response. This byte is only available if STATUS = 0x95. SEC-STATUS: Block security status . Note: This command is only available for ISO15693 Transponders FEIG ELECTRONIC GmbH Page 105 of 144 H40801-5e-ID-B.doc...
  • Page 106: 0Xbf] Iso15693 Transparent Command

    302µs. If there is no response within 20ms the command sends back Status “no Transponder” 0x01 b011 = write request with Option “1” The Reader tries to sample the response after CMD-RES-DELAY. If there is see ANNEX D: Index of Status Bytes FEIG ELECTRONIC GmbH Page 106 of 144 H40801-5e-ID-B.doc...
  • Page 107 Reader should code the data in the RF forward link and decode the data in the RF return link. TxCRCEn: A CRC is calculated over the transmitted data and the CRC byte(s) are appended to the data stream FEIG ELECTRONIC GmbH Page 107 of 144 H40801-5e-ID-B.doc...
  • Page 108 • The response data ever contains the in RSP-LENGTH defined number of data bytes. Note: • This command is only available for ISO15693 Transponders. • This command is not available if the Scan Mode or Buffered Read Mode is switched on. FEIG ELECTRONIC GmbH Page 108 of 144 H40801-5e-ID-B.doc...
  • Page 109: Special Commands

    • If the EPC doesn't match, the reader also answers with status [0x83]. • If the command was not successfully (reader may continue read the EPC), the reader an- swers with status [0x03]. FEIG ELECTRONIC GmbH Page 109 of 144 H40801-5e-ID-B.doc...
  • Page 110: Supported Iso15693 Host Commands

    Reading of one block in non addressed mode is only possible, if parameter “Read Mode” in CFG4 is set to “10: Multiple Read“. The WR-OPTION will be set automatically by the FEIG Readers if the WR-OPTION parameter in “CFG4 Transponder Parameters” is set to “00: automatically set”. FEIG ELECTRONIC GmbH Page 110 of 144 H40801-5e-ID-B.doc...
  • Page 111: Em Microelectronics (Em4135)

    Reading of one block in non addressed mode is only possible, if parameter “Read Mode” in CFG8 is set to “10: Multiple Read“. The WR-OPTION will be set automatically by the FEIG Readers if the WR-OPTION parameter in “CFG4 Transponder Parameters” is set to “00: automatically set”. FEIG ELECTRONIC GmbH Page 111 of 144 H40801-5e-ID-B.doc...
  • Page 112: Fujitsu (Mb89R116)

    The WR-OPTION will be set automatically by the FEIG Readers if the WR-OPTION parameter is set to “00: automatically set”. Up to two blocks of data can be written for one request. FEIG ELECTRONIC GmbH Page 112 of 144 H40801-5e-ID-B.doc...
  • Page 113: Fujitsu (Mb89R118)

    The WR-OPTION will be set automatically by the FEIG Readers if the WR-OPTION parameter is set to “00: automatically set”. Up to two blocks of data can be written for one request. FEIG ELECTRONIC GmbH Page 113 of 144 H40801-5e-ID-B.doc...
  • Page 114: Fujitsu (Mb89R119)

    The WR-OPTION will be set automatically by the FEIG Readers if the WR-OPTION parameter is set to “00: automatically set”. Up to two blocks of data can be written for one request. FEIG ELECTRONIC GmbH Page 114 of 144 H40801-5e-ID-B.doc...
  • Page 115: Infineon (My-D Page Mode) 0X60

    “CFG4 Transponder Parameters” is set to “00: automatically set”. The user has to take the Custom Specific Commands Read [0x10], Write [0x30] and the Wri- te Byte [0x90]. The commands will be not used automatically by the Reader. FEIG ELECTRONIC GmbH Page 115 of 144 H40801-5e-ID-B.doc...
  • Page 116: Infineon (Iso Address Mode) 0Xe0

    Get Multiple Block Security √ √ √ √ 0x2C Status ∗ The WR-OPTION will be set automatically by the FEIG Readers if the WR-OPTION parameter in “CFG4 Transponder Parameters” is set to “00: automatically set”. FEIG ELECTRONIC GmbH Page 116 of 144 H40801-5e-ID-B.doc...
  • Page 117: Infineon (My-D Light)

    “CFG4 Transponder Parameters” is set to “00: automatically set”. Reading of more than one block in non addressed mode is only possible, if parameter “Read Mode” in CFG4 is set to “01: Single Read“. FEIG ELECTRONIC GmbH Page 117 of 144 H40801-5e-ID-B.doc...
  • Page 118: Nxp (I-Code Sli)

    √ 0x2C Get Multiple Block Security Status ∗ The WR-OPTION will be set automatically by the FEIG Readers if the WR-OPTION parameter in “CFG4 Transponder Parameters” is set to “00: automatically set”. FEIG ELECTRONIC GmbH Page 118 of 144 H40801-5e-ID-B.doc...
  • Page 119: Nxp (I-Code Sli-S)

    “CFG4 Transponder Parameters” is set to “00: automatically set”. Reading of more than one block in non addressed mode is only possible, if parameter “Read Mode” in CFG4 is set to “01: Single Read“. FEIG ELECTRONIC GmbH Page 119 of 144 H40801-5e-ID-B.doc...
  • Page 120: Nxp (I-Code Sli-L)

    “ CFG4 Transponder Parameters” is set to “00: automatically set”. Reading of more than one block in non addressed mode is only possible, if parameter “Read Mode” in CFG4 is set to “01: Single Read“. FEIG ELECTRONIC GmbH Page 120 of 144 H40801-5e-ID-B.doc...
  • Page 121: Stmicroelectronics (Lri512)

    ”CFG4 Transponder Parameter” is set to “00: automatically set”. Reading of more than one block in non addressed mode is only possible, if parameter “Read Mode” in CFG4 is set to “01: Single Read“. FEIG ELECTRONIC GmbH Page 121 of 144 H40801-5e-ID-B.doc...
  • Page 122: Stmicroelectronics (Lri64)

    ”CFG4 Transponder Parameter” is set to “00: automatically set”. Reading in non addressed mode is only possible, if parameter “Read Mode” is set to “01”: Single Read“ and DB-Blocksize is set to “1” in CFG4. FEIG ELECTRONIC GmbH Page 122 of 144 H40801-5e-ID-B.doc...
  • Page 123: Stmicroelectronics (Lri2K / Lris2K)

    ”CFG4 Transponder Parameter” is set to “00: automatically set”. Reading of LRIS2k in non addressed mode is only possible, if parameter “Read Mode” is set to “01”: Single Read“ in CFG4. FEIG ELECTRONIC GmbH Page 123 of 144 H40801-5e-ID-B.doc...
  • Page 124: Texas Instruments (Tag-It Hfi Pro / Standard)

    Single Read √ √ √ √ 0x24 Write Multiple Blocks 0x25 Select 0x26 Reset to Ready 0x27 Write AFI 0x28 Lock AFI 0x29 Write DSFID 0x2A Lock DSFID 0x2B Get System Information FEIG ELECTRONIC GmbH Page 124 of 144 H40801-5e-ID-B.doc...
  • Page 125 The WR-OPTION will be set automatically by the FEIG Readers if the WR-OPTION parame- ter in “CFG4 General” is set to “00: automatically set”. When using the “non-addressed” mode the WR-OPTION must be set manually to “WR- OPTION = 1”. FEIG ELECTRONIC GmbH Page 125 of 144 H40801-5e-ID-B.doc...
  • Page 126: Texas Instruments (Tag-It Hfi Plus)

    Inventory Read Multiple Blocks 0xAB Inventory Get System Infor- mation 0xAC Inventory Get Multiple Block Security Status √ √ √ √ 0xA2 Write 2 Blocks √ √ √ √ 0xA3 Lock 2 Blocks FEIG ELECTRONIC GmbH Page 126 of 144 H40801-5e-ID-B.doc...
  • Page 127 This will only become an effect if the block address starts with an even-numbered ad- dress. • In the case of writing / locking an odd number of blocks the “Write_2_Blocks”/“Lock_2_Blocks” command will be combined with the “write single Block”/ “Lock single Block” command. FEIG ELECTRONIC GmbH Page 127 of 144 H40801-5e-ID-B.doc...
  • Page 128: Supported Iso15693 Host Commands For I-Code Epc Transponders

    Reset to Ready 0x27 Write AFI 0x28 Lock AFI 0x29 Write DSFID 0x2A Lock DSFID 0x2B Get System Information Get Multiple Block Security 0x2C Status 0xA0 Read Config Block 0xA1 Write Config Block FEIG ELECTRONIC GmbH Page 128 of 144 H40801-5e-ID-B.doc...
  • Page 129: Supported Iso15693 Host Commands For I-Code Uid Transponders

    Reset to Ready 0x27 Write AFI 0x28 Lock AFI 0x29 Write DSFID 0x2A Lock DSFID 0x2B Get System Information Get Multiple Block Security 0x2C Status 0xA0 Read Config Block 0xA1 Write Config Block FEIG ELECTRONIC GmbH Page 129 of 144 H40801-5e-ID-B.doc...
  • Page 130: Protocols For Buffered Read Mode

    Host is able to do other jobs e.g. to communicate with other Readers Additional information about the capacity of the data buffer can be determined with the 10.4. [0x31] Read Data Buffer Info command. FEIG ELECTRONIC GmbH Page 130 of 144 H40801-5e-ID-B.doc...
  • Page 131: Transponder Access In The Buffered Read Mode

    The Buffered Read Mode only reads data blocks from the Transponders in the antenna field The anticollision procedure can be configured in the 3.7. CFG5: Anticollision configuration block. con- figuration block are used. FEIG ELECTRONIC GmbH Page 131 of 144 H40801-5e-ID-B.doc...
  • Page 132: 0X22] Read Buffer

    DB = data block Byte Order = b0:MSB first, b1:LSB first ANT-No = Antenna number if a antenna multiplexer is used. Without multiplexer it is set to TIMER = internal system timer FEIG ELECTRONIC GmbH Page 132 of 144 H40801-5e-ID-B.doc...
  • Page 133 Transponder is read will by set in the bit field. Bit: Function ANT8 ANT7 ANT6 ANT5 ANT4 ANT3 ANT2 ANT1 FEIG ELECTRONIC GmbH Page 133 of 144 H40801-5e-ID-B.doc...
  • Page 134 • This command is only available in the Buffered Read Mode. • Data are only transferred if STATUS = 0x00, 0x83, 0x84, 0x93, 0x94. • If STATUS = 0x83, 0x84, 0x85 the TR-DATA and DATA SETS will be always trans- ferred. FEIG ELECTRONIC GmbH Page 134 of 144 H40801-5e-ID-B.doc...
  • Page 135: 0X31] Read Data Buffer Info

    Number of Transponder data sets reserved in the data buffer. Notes: • Additional information about the data table status is transferred if STATUS = 0x00, 0x84, 0x85, 0x93. see ANNEX D: Index of Status Bytes FEIG ELECTRONIC GmbH Page 135 of 144 H40801-5e-ID-B.doc...
  • Page 136: 0X32] Clear Data Buffer

    The command Initialize Buffer clears the data buffer to an initial state. It does not matter if the data sets in the data buffer were read or not. Host → Reader 4...5 COM-ADR [0x33] CRC16 Host ← Reader 5...6 COM-ADR [0x33] STATUS CRC16 see ANNEX D: Index of Status Bytes FEIG ELECTRONIC GmbH Page 136 of 144 H40801-5e-ID-B.doc...
  • Page 137: Annex

    ANNEX A: Codes of Transponder Types Value Transponder type 0x03 ISO15693 Tags 0x06 Philips I-Code EPC 0x07 Philips I-Code UID The Information will be send by performing the 6.1.1. [0x01] Inventory command. FEIG ELECTRONIC GmbH Page 137 of 144 H40801-5e-ID-B.doc...
  • Page 138: Annex B: Time Behavior Of The Asynchronous Interface

    1 Block (16 Bytes) all ( 8 ) Blocks 5.7. [0x69] RF Reset 6.1. [0xB0] Host com- mands for ISO15693 Man- datory and Optional Com- mands as configured in 3.3. CFG1: Interface TR-RESPONSE-TIME FEIG ELECTRONIC GmbH Page 138 of 144 H40801-5e-ID-B.doc...
  • Page 139: Annex C: Time Behavior Of Iso15693 Host Commands

    The extent of the data that needs to be read or written • Types of Transponders supported by the Reader, • Position of the Transponder at the time of the requirement, • Probable local electromagnetic interferences present. FEIG ELECTRONIC GmbH Page 139 of 144 H40801-5e-ID-B.doc...
  • Page 140: Time Behavior For [0X01] Inventory And Iso15693 Transponders

    The timing is measured inclusive of the communication time at 38,4Kbaud. A modified baud rate will slightly increase the timing but the Inventory timing is mostly determine by the anticollision so you may neglect the communication time. Execution time Communication time FEIG ELECTRONIC GmbH Page 140 of 144 H40801-5e-ID-B.doc...
  • Page 141: Annex D: Index Of Status Bytes

    The address is beyond the configured address space of the Transponder. 0x05 Wrong Transponder-type: This command is not applicable at the Transponder: • Attempt to write on or read from a Transponder. • A special command is not applicable to the Transponder. FEIG ELECTRONIC GmbH Page 141 of 144 H40801-5e-ID-B.doc...
  • Page 142 1. Read the Device-ID using the command [0x66] Firmware version (Mode 0x80) 2. Send the Device-ID and the serial number of the reader to Feig Electronic 3. Write the upgrade code into the reader using the command [0x5F] Set Firmware Update...
  • Page 143: Annex E: Codes Of Reader Types

    ID ISC.LR100 ID ISC.LR200 ID ISC.LRU1000 ID CPR.M02 ID CPR.02 ID CPR.M03 (586/#) ID CPR04-U ID ISC MR101-U / PR101-U ID ISC.MR101-A / PR101-A ID ISC.PRH101-A (RS232 or Bluetooth) ID ISC.PRH101-U (USB-Version) FEIG ELECTRONIC GmbH Page 143 of 144 H40801-5e-ID-B.doc...
  • Page 144: Annex I: Examples For Read Data

    The setting "LSB first" and "MSB first" gives the direction of the received data bytes ISO15693 Host Command (DB-Size of the Transponder = 4 bytes) ISO15693 Host Command (DB-Size of the Transponder = 8 bytes) FEIG ELECTRONIC GmbH Page 144 of 144 H40801-5e-ID-B.doc...

Table of Contents