Summary of Contents for Feig Electronic ID ISC.LRU1002
Page 1
INSTALLATION ID ISC.LRU1002 (EU: 4127.001.00; FCC: 4128.001.00) UHF Long Range Reader final – public (B) 2017-05-05 – M61110-2e-ID-B.docx...
Page 2
FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to a human.
IDENTIFICATION Installation ID ISC.LRU1002 Contents 1. Safety Instructions / Warning - Read before start-up ! 2. Performance Features of Reader Family ID ISC.LRU1002 2.1. Performance features ......................6 2.2. Available reader types....................... 6 3. Installation 4. Terminals 4.1. Antenna Connection ......................9 4.2.
Page 4
IDENTIFICATION Installation ID ISC.LRU1002 5.3.1. EU reader according to EN302 208 ................24 5.3.2. FCC-Reader according to FCC 47 Part 15 ..............25 6. Technical Data 7. Radio Approvals 7.1. Europe (CE) ........................29 7.2. USA (FCC) and Canada (IC) .................... 30 7.2.1.
IDENTIFICATION Installation ID ISC.LRU1002 1. Safety Instructions / Warning - Read before start-up ! The device may only be used for the intended purpose designed by for the manufacturer. The operation manual should be conveniently kept available at all times for each user.
IDENTIFICATION Installation ID ISC.LRU1002 2. Performance Features of Reader Family ID ISC.LRU1002 2.1. Performance features The reader has been developed for reading passive data carriers, so-called „Smart Labels“, using an operating frequency in the UHF range. The output power is configurable in the range between 100 mW and 2 W.
IDENTIFICATION Installation ID ISC.LRU1002 3. Installation The Reader is designed for wall-mount, including outdoors. Outdoors the reader should be mounted like shown in the picture below to ensure the watertightness of the device. Holes for mounting on a wall with countersunk head screws are provided in the housing. The maximum head screw diameter should not exceed 8,0 mm.
IDENTIFICATION Installation ID ISC.LRU1002 4. Terminals On the lower side of the reader housing different connectors are positioned. Figure 2 shows the arrangement of the connectors and Table 2: Connection terminals gives an overview on the avail- able interfaces and signals. Table 3: Push button function shows the available push buttons.
IDENTIFICATION Installation ID ISC.LRU1002 4.1. Antenna Connection The external SMA antenna connectors are positioned on the lower side of the reader. The maximum tightening torque for the SMA sockets is 0.45 Nm (4.0 lbf in). For supplying a DC voltage to external components e.g. the UHF antenna multiplexer ID ISC.ANT.UMUX, it is possible to enable a supply voltage (24 V DC / max.
IDENTIFICATION Installation ID ISC.LRU1002 4.2. Power Supply 4.2.1. Power Supply via connection X2 The supply voltage of 24 V DC has to be connected to Terminal X2. Figure 4: Connector X2 Pin assignment for power supply Table 5: Pin assignment for power supply...
IDENTIFICATION Installation ID ISC.LRU1002 4.3. Interfaces 4.3.1. Ethernet Interface on connector X1 The Reader has an integrated 10 / 100 base-T network port for an RJ-45. Connection is made on X1 and has an automatic “Crossover Detection” according to the 100BASE-T Standard.
USB flash drive. The meaning of the CONFIG.INI will be described in the next chapter. After plug-in of the USB flash drive the green and red status LED of the ID ISC.LRU1002 are per- manently lit as long as the USB flash drive is actively used by the reader. When the USB actions are completed successfully, the red LED is switched off and the green LED starts flashing.
IDENTIFICATION Installation ID ISC.LRU1002 4.3.2.3. Storing the reader configuration on a USB flash drive While connecting the USB flash drive on a running reader, the reader will store the configuration as a editable and readable CSV-file (CONFIG.INI) on the USB flash drive. This file will be stored in the main directory for easy coping of the configuration (4.3.2.4.
Page 14
IDENTIFICATION Installation ID ISC.LRU1002 Note: Connecting an USB flash drive on a running reader will always overwrite an existing con- figuration file in the main directory on the USB flash drive (see 4.3.2.3. Storing the reader configuration on a USB flash drive).
IDENTIFICATION Installation ID ISC.LRU1002 4.3.3. RS232 Interface on connector X4 The RS232 interface is connected on X4. The transmission parameters can be configured by means of software protocol. Figure 7: RS232 interface pin-outs on X4 Table 7: Pin Assignment RS232 Interface...
IDENTIFICATION Installation ID ISC.LRU1002 4.3.4. Data-Clock Interface on connector X4 The connection of the data-clock interface takes place via the digital Outputs OUT1 and OUT2 at connector X4. The wire for the clock (Data-0) needs to be connected to connector OUT1-E, the wire for the data (Data-1) needs to be connected to connector OUT2-E.
Page 17
IDENTIFICATION Installation ID ISC.LRU1002 See Notes below for resistor values Figure 10: Wiring Example NOTE: Please consider possible limitations of the Wiegand Controller regarding the used supply voltage. The necessity of the external pull down resistor is depending on the inner circuit of the...
IDENTIFICATION Installation ID ISC.LRU1002 4.4. Inputs and Outputs on connector X4 4.4.1. 24 V DC voltage on connector X4 A 24 V DC voltage can be received on Pin 4 of connector X4. It can be used e.g. to drive the digital Inputs and Outputs of the reader.
IDENTIFICATION Installation ID ISC.LRU1002 4.4.2. Digital Inputs on connector X4 The optocouplers on Terminal X4 are galvanically isolated from the Reader electronics and must therefore be externally supplied. Figure 12: Digital inputs IN1 / IN2 Table 10: Pin Assignment digital Inputs IN1 / IN2...
IDENTIFICATION Installation ID ISC.LRU1002 4.4.3. Digital outputs on connector X4 The transistor connections, collector and emitter, of the optocoupler output are galvanically isolated from the Reader electronics and are carried to the outside without any internal ancillary circuitry on Terminal X4. The output must therefore be powered by an external power supply.
IDENTIFICATION Installation ID ISC.LRU1002 5. Operating and Display Elements 5.1. Status LED Table 13: Configuration of the LED Host Warning Communication Antenna 1- 4 Green Yellow Description FLASH Normal Reader operation FLASH FLASH Reader receives a valid protocol from host...
IDENTIFICATION Installation ID ISC.LRU1002 5.2. Reset Push Button T1 By means of the push button T1 a complete configuration reset can be performed. The push button is positioned in the middle between the antenna connectors ANT3 and ANT4. Figure 18 shows the position of the push button.
** Correction Factor to convert the radiated power from e.r.p to e.i.r.p. an Excel file „Calc-RF-Power.xls“ can be used. For the calculation of the reader output power P Available from Feig Electronic GmbH. Example: ** linear antenna = „0“, circular antenna = „1“...
IDENTIFICATION Installation ID ISC.LRU1002 5.3.2. FCC Reader according to FCC 47 Part 15 According to the FCC approval, Title 47, Part15 the maximum output power of the reader is limited to 1 W (30dBm). The maximum radiated power of the antenna should not increase more than 4 W e.i.r.p.
IDENTIFICATION Installation ID ISC.LRU1002 6. Technical Data MECHANICAL DATA Housing Aluminum powder-coated Dimension (W x H x D) 260 mm x 157 mm x 68 mm 10.2 inch x 6.2 inch x 2.7 inch Weight 1,8 kg (4.0 lb) Protection Class...
Page 27
IDENTIFICATION Installation ID ISC.LRU1002 Interfaces RS232 USB Mini (USB 2.0; Full Speed; On-The-Go) Ethernet (10/100 BASE-T; MDI/MDI-X cross over detection; IPv4) Wiegand (Scan Mode Schnittstelle) FUNCTIONAL PROPERTIES Protocol Modes FEIG ISO HOST Mode (Advanced Protocol Frame) Buffered Read Mode Automatic Data...
Page 28
IDENTIFICATION Installation ID ISC.LRU1002 APPLICABLE STANDARDS Radio Regulation Europe EN 302 208 USA FCC 47 CFR Part 15 Canada IC RSS-210 EN 301 489 Safety Low Voltage EN 62368-1 Human Exposure EN 50364 FEIG ELECTRONIC GmbH Page 28 of 32 M61110-2e-ID-B.docx...
7. Radio Approvals 7.1. Europe (CE) Hereby, FEIG ELECTRONIC GmbH declares that the radio equipment type ID ISC.LRU1002 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: http://www.feig.de/en/downloads-support/declarations-of-conformity.html...
Warning: Changes or modification made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment. FEIG ELECTRONIC GmbH Page 30 of 32...
IDENTIFICATION Installation ID ISC.LRU1002 7.2.2. Label Information The following information must be placed at the outer side of the housing in which the reader is mounted. Contains FCC ID PJMLRU1002A Contains IC: 6633A-LRU1002A 7.2.3. Installation with FCC / IC Approval...
ANNEX A - Accessories Following optional accessories are available: Order No. Article Description Plastic Sealing Cap for Reader Connectors with Steel Conduit Pipe Thread (PG) for ID ISC.LRU3x00 and ID ISC.LRU1002 ID ISC.LR.CSC-IP64 3558.000.00 Connector Sealing Cap ID ISC.LRU3x00-MS 3831.000.00 Mounting Rail Set for ID ISC.LRU3x00 and ID ISC.LRU1002...
Need help?
Do you have a question about the ID ISC.LRU1002 and is the answer not in the manual?
Questions and answers