Place And Connect; Gas Connection; Electrical Connection - Siemens HX9R3AE50 User Manual

Hide thumbs Also See for HX9R3AE50:
Table of Contents

Advertisement

NL

Place and connect

5 Place and connect
Do not install the appliance behind a decor or
Place s and conn nect s
furniture door. Then there is the risk of overheating.

gas connection

The installation may only be carried out by an
authorized installer or a service technician
authorized by the importer in accordance with
the "Instruction for connecting the gas and
changing the gas type".
For the installer or service department approved by
the importer
Attention!
The setting conditions for this device are stated on
the type plate on the back of the device. The gas type
set at the factory is marked with a star (*).
Before setting up the device, check the distribution
conditions (gas type and gas pressure) and make
sure that the gas setting of the device is set
accordingly. If the settings of the appliance need to
be changed, see the instructions in the chapter
"Instruction for connecting the gas and changing
the gas type".
This appliance is not connected to a flue gas outlet.
The device must be in
be connected and put into operation in accordance
with the installation instructions. Do not connect
the appliance to a flue gas outlet. All ventilation
regulations must be observed.
The gas connection must be made via a fixed, non-
flexible connection (gas pipe) or via a safety hose.
If a safety hose is used, it must be ensured that the
hose is not pinched or kinked. The hose must not
come into contact with hot surfaces.
* The gas pipe (gas pipe or gas safety hose) can be
connected to either the right or left side of the
appliance. The connection must have an easy
accessible closing device.
* : Optional. Available with some devices.
Nominal operating pressure of the device
The rated operating pressure of the device is stated on
the rating plate on the back of the device.
All information on the type plate of your device refers to
these pressure values. The manufacturer is not
responsible for results, performance or any risk
resulting from the use of this device at non-standard
pressures.
:
Warning – Safety Notice!
If the gas pressure in your electricity network is higher
(20%) than the value stated on the type plate of the
appliance, you must use the appliance for your
10
safety must be used with a suitable gas regulator.
If you are unsure of the gas pressure in your electrical
grid, please contact your local power company. The
connection, maintenance and adjustment of the gas
regulator must be carried out by technical personnel of
the network operator.
Move the appliance on the gas pipe or on the
door handle
Do not move the appliance by pulling on the gas pipe;
the gas pipe can be damaged. Danger of a gas leak! Do
not move the appliance by pulling the door handle.
Door hinges and door handle can be damaged.

Electrical connection

The device is suitable for a mains voltage of 220-240
V. A fuse of 16 A is required for connection.
Have the appliance installed by a service department.
If the device is connected incorrectly, the warranty will
lapse in the event of damage.
Attention!
When the mains voltage drops below 180 V, the
electrical
ignition system no more.
If the connection cable is damaged, it must be
replaced by the manufacturer, its service agent or an
authorized technician.
:
Warning – Danger to life!
There is a risk of electrocution when in contact with
live parts.
Only handle the plug with dry hands.
When you pull out the connection cable, always
handle it directly by the plug and not by the cable
itself, as this may be damaged.
Never pull the plug out of the socket during use.
Adhere to the following instructions and make sure that:
Clues
the plug fits into the socket.
the cross section of the electrical cable is
large enough.
the grounding system has been properly
installed.
the connection cable (if necessary) must only be
replaced by a qualified technician. A new cable is
available from the after-sales service. multiple plugs/
sockets and/or extension cables are not used.
when using an earth leakage circuit breaker, only a
type with the symbol
Only RCDs with this symbol comply with applicable
regulations.
the plug is always accessible.
the connection cable is not kinked, pinched,
altered or cut.
the connection cable does not come into contact
with heat sources.
is used.
z

Advertisement

Table of Contents
loading

Table of Contents