Bulk seed tender
Table of Contents

Advertisement

Operator's Manual: 405 SLD Seed Express
d. GATE 1 and GATE 2:
The Slide Gate buttons open and close the
slide gates at the bottom of compartment 1
and 2. Hold either button to fully open or fully
close. Release the button when the desired
amount of product flow is achieved.
e. CONV - FRONT/REAR:
These
Conveyor
conveyor tube around the driver side. Press
the FRONT button to move the conveyor
towards the hitch. Press the REAR button to
move the conveyor rearward.
f.
CONV - UP/DOWN:
These Conveyor buttons raise and lower the
conveyor tube. Press the UP button to raise
and the DOWN button to lower the conveyor.
g. TARE:
The Tare button will reset the scale to
zero in order to measure only the content
being added to one compartment without
measuring the weight of the seed tender
itself. This allows an exact measurement of
the seed to be placed in the compartment.
h. ENG START:
Start the engine with this button.
Note: If the engine has not been started
recently set the choke to ON.
Revised 08.2021
Bulk Seed Tender
buttons
swings
the
®
i.
AUTO RESET:
Pressing the AUTO RESET button on
the handset will dispense the Weight To
Dispense out the selected gate. The gate that
was selected in the Active Gate screen will
open in #s. The unit will monitor the weight
being dispensed. As the weight approaches
the desired Weight To Dispense, the gate will
begin to close. If the weight stops changing
too soon, the unit will open the gate slowly in
order to get the desired amount.
i.
The auto reset mode does not turn the
conveyor ON. The desired speed for the
conveyor should be set manually.
ii. If the remote control is in the middle of
auto dispense mode and the handset
goes out of range, the unit will close
all open gates regardless the status of
dispensing.
iii. If the remote goes into the sleep mode
during the auto dispense mode, the unit
will abort the auto dispense mode and
close the active gate.
iv. Pressing any of the gate function buttons
on the handset will close the active gate
and stop the auto dispense mode.
v. If, during the auto dispense mode, the
POWER button is pressed, the active
gate will close.
®