Audio stream loss duration (ms) : Set the time value before a interrupted connection (no IP packet
●
received) is considered lost and the communication is ended by the unit. Default value is 1000ms.
●
Confirm the settings by clicking on 'Apply'.
2.2.2. Audio In/Out
These parameters set the "traditional" audio inputs / outputs on the unit.
●
Click on "Configure" button to be able to modify the parameters.
Type : Audio input on the unit is to be chosen between analog and AES input. Both analog and AES output
●
are active.
Input and Output Line levels : Input and Output levels can also be set. These s liders allow selecting the
●
maximum expected level of the analog input signal on left and right channels, in dBu, by steps of 0.5 dBu.
For instance a selected value of +18 means the input signal max value is +18 dBu.
IQOYA *CALL and *CALL/LE accept a maximum analog level of +24 dBu. For a level value selected
between 6 and 24, the analog input gain is set so that 0 dBfs is reached when the input signal reaches this
value.
I QOYA *CALL - IQOYA *CALL/LE
User Manual v0.99
33 / 77