Anomaly Table - Electrolux SPEEDELIGHT Installation And Operating Manual

Hide thumbs Also See for SPEEDELIGHT:
Table of Contents

Advertisement

L.2

Anomaly table

If the appliance does not start or stops during operation, first try to find a solution to the problem referring to the table below. If not,
contact the Customer Service.
With some anomalies, you can hear some acoustic signals and the display shows an error massage.
Anomaly
Anomaly type
Display shows a
Blocking machine
BIG YELLOW
TRIANGLE
Display shows a
Warning
BIG RED TRIAN-
GLE WITH ONE
BLUE AIR
WHIFFLE
Display shows a
Warning
BIG RED TRIAN-
GLE WITH TWO
BLUE AIR
WHIFFLES
Display shows a
Warning
BIG RED TRIAN-
GLE WITH
THREE BLUE
AIR WHIFFLES
COMM
Blocking machine
NTC_HVT
Blocking MW
T_WT
Blocking machine
T_UP
Blocking machine
ZC_FAIL
Blocking machine
Description
Possible causes
An error occurred.
See cause/s relevant to
LOG access is
the error LOG report.
needed to discover
the error.
Cooling phase
Many sandwiches cooked
in quick sequence using
because of overtem-
perature detected at
microwaves.
the transformer.
Cooling phase
1. Long time microwaves
because of overtem-
perature detected at
2. Room temperature
the magnetron.
3. Magnetron fault.
Cooling phase
1. Cooking with no food
because of overtem-
perature detected on
2. PT1000 WT tempera-
the glass.
Communication error
• Internal error;
between ACU and UI
• ACU and UI
boards.
• MW internal leakage;
• Faulty ACU - Faulty UI.
HV transformer: NTC
Internal error;
sensor mal-function
NTC HVT not properly
(disconnected or in
cabled;
short circuit).
NTC HVT failure.
Working Top PT1000
PT1000 WT not properly
sensor mal-function
cabled;
(disconnected or in
PT1000 WT failure.
short circuit).
Upper Plate PT1000
PT1000 UP not proper-ly
sensor malfunction
cabled;
(disconnected or in
PT1000 UP failure.
short circuit).
ZC signal absent.
KLX3 open (components
Lack of power to
over temperature);
heaters and
J18 on board
magnetrons.
disconnected;
KM malfunction;
RL5 on ACU malfunction:
faulty ACU.
Actions
1. Press simultaneously but-
2. Select the line reporting the
3. Press ENTER (bottom left
4. Report to call centre.
1. Wait for the appliance to
2. Reduce microwaves cook-
1. Wait for the appliance to
use.
2. Reduce microwaves cook-
above 35°C/95°F.
3. In case the warning does
1. Wait for the appliance to
on the glass;
2. Be sure food is in place
ture sensor not in
contact with glass.
3. In case of persistent warn-
If the error persists, call Service.
disconnected;
• Turn machine OFF and on;
• If the error persists, call
• Check if burned spots are
• Call Service and report the
Check if any visible damages
at the flexible tube of the lid;
Call Service and report the
above findings if any.
Check if the machine is
exposed to external heat
sources;
Call Service and report the
above findings.
tons "1" and "2" to access
the error list;
latest generated error;
side hand button) and read
the error description;
cool down;
ing intensity;
cool down;
ing intensity;
not disappear after some
minutes, call Service;
cool down;
before starting a consistent
cooking cycle;
ing even after setting the
cooking in the proper way,
call Service.
Service.
visible in the centre of the
glass;
above findings.
33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

603909603878603908603886603877603885

Table of Contents