Everbilt EB-PUMP-T Use And Care Manual page 7

Condensate pump with clear vinyl tubing
Table of Contents

Advertisement

Available languages

Available languages

Installation (continued)
7
Attaching the pump inlet covers
□ Attach the pump inlet covers (B) to the remaining
condensate pump (A) inlet holes.
NOTE: Covering inlet holes prevents the condensate
pump (A) from collecting debris or insects.
9
Connecting the power
WARNING: Risk of electrical shock! This pump must be
properly connected to power following the National Electric
Code (NEC). Never cut the cord or ground plug. Failure to
follow these warnings will void the warranty and could
result in a fatal electric shock.
□ Plug the condensate pump (A) into a properly grounded
3-prong 120 volt ground fault circuit interrupter (GFCI)
outlet. A green LED (1) will indicate if power is available.
NOTE: Do not plug the condensate pump (A) into an
extension cord or connect to a power source that may be
inadvertently or automatically turned off.
B
A
8
Attaching the wires
WARNING: Risk of electrical shock! Ensure that power
to the A/C unit / furnace and the pump is shut off before
attempting this step! Failure to follow these warnings will
void the warranty and could result in a fatal electric shock.
in the wiring diagram. If the wiring is not present from
the air conditioner, contact HVAC professional (optional,
advanced).
NOTE: A pump safety switch should be used on
24V Class II control circuits only.
C
7
l P
a e
e s
o c
t n
Wires from
air conditioner
(if present)
Typical Thermostat
R
W
G
Y
Com
Run
R
W
G
Y
Typical Thermostat
Connections of Appliance