Everbilt SP03302VD Use And Care Manual

Everbilt SP03302VD Use And Care Manual

Submersible sump pump
Hide thumbs Also See for SP03302VD:
Table of Contents

Advertisement

Available languages

Available languages

SKU# 1000026686 1000026682
1000026675 1000026662
Model# SP03302VD SP05002VD
PSSP07501VD PSSP10001VD
USE AND CARE GUIDE
SUBMERSIBLE SUMP PUMP
SP03302VD SP05002VD
PSSP07501VD PSSP10001VD
Questions, problems, missing parts? Before returning to the store call
Everbilt Customer Service
8 a.m. - 6 p.m., EST, Monday-Friday
1-844-241-5521
HOMEDEPOT.COM
THANK YOU
We appreciate the trust and confidence you have placed in Everbilt through the purchase of this submersible sump pump. We strive to continually
create quality products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs.
Thank you for choosing Everbilt!

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Everbilt SP03302VD

  • Page 1 THANK YOU We appreciate the trust and confidence you have placed in Everbilt through the purchase of this submersible sump pump. We strive to continually create quality products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs.
  • Page 2: Table Of Contents

    Table of Contents Table of Contents ............2 MATERIALS REQUIRED (NOT INCLUDED) ......4 Performance ..............2 PACKAGE CONTENTS ............5 Safety Information ............2 SPECIFICATIONS .............. 5 Warranty ................. 3 Installation ..............6 Pre-Installation .............. 4 Operation ............... 7 APPLICATION ..............
  • Page 3: Warranty

    Safety Information (continued) CAUTION: Follow all local electrical and safety WARNING: Ensure that the electrical circuit to the pump codes, along with the National Electrical Code (NEC). In is protected by a15 Amp fuse or circuit breaker. addition, all Occupational Safety and Health Administration (OSHA) guidelines must be followed.
  • Page 4: Pre-Installation

    Pre-Installation APPLICATION This submersible sump pump is designed for home sump applications. Use this pump only for pumping water. This pump has not been tested or approved for use in swimming pools or in salt-water marine areas. It is also not engineered to be run continuously as a “fountain”...
  • Page 5: Package Contents

    Pre-Installation (continued) PACKAGE CONTENTS NOTE: The adaptor is not shown to scale. Part Description Pump 1-1/4 in. adaptor SPECIFICATIONS Power supply 115V, 60 HZ., 15 Amp Circuit Liquid temp. range 32°F to 77°F(0°- 25°C) Discharge size 1-1/2 in. FNPT or 1-1/4 in. FNPT (with adaptor) Minimum 10 in.
  • Page 6: Installation

    Installation CAUTION: Always use the handle to lift the pump. Never use the power cord to lift the pump. To avoid skin burns, unplug the pump and allow time for it to cool after periods of extended use. Attaching the discharge pipe Installing the adaptor connection For 1-1/2 in.
  • Page 7: Operation

    Operation DANGER: Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface, or in water. Function Verification Plug the power plug into a 115V GFCI power outlet.  Check the pump by filling the sump pit with water and observe the pump’s operation through one complete cycle. Make sure the ...
  • Page 8: Care And Cleaning

    Care and Cleaning CAUTION: Always use the handle to lift the pump. Never use the power cord to lift the pump. To avoid skin burns, unplug the pump and allow time for it to cool after periods of extended use. Do Not When the power is disconnected, inspect the pump suction Do not disassemble the motor housing.
  • Page 9: Troubleshooting

    Troubleshooting Problem Possible Cause Corrective Action The pump does not start or run. 1. The fuse is blown. 1. Replace the fuse. 2. The breaker is tripped. 2. Reset the breaker. 3. The plug is disconnected. 3. Secure the plug. 4.
  • Page 10 Questions, problems, missing parts? Before returning to the store call Everbilt Customer Service 8 a.m. - 6 p.m., EST, Monday-Friday 1-844-241-5521 HOMEDEPOT.COM...
  • Page 11 ¡GRACIAS! Nosotros agradecemos la confianza que Usted ha puesto en Everbilt por la compra de esta bomba de utilidad sumergible. Nos esforzamos continuamente para crear productos de calidad diseñados para mejorar su hogar. Visítenos en nuestra página de internet para ver la...
  • Page 12: Funcionamiento

    Table Des matières Table Des matières ............. 12 MATERIALES REQUERIDOS (NO INCLUIDOS) ....14 Funcionamiento ............12 CONTENIDO DEL PAQUETE ..........15 Información De Seguridad ......... 12 Especificaciones ............15 Garantía ................ 13 Montaje ................ 16 Pre-Montaje ..............14 Operación ..............17 Aplicación ..............
  • Page 13: Garantía

    Información De Seguridad (seguido) ADVERTENCIA: Asegúrese de que el circuito eléctrico a CAUTELA: Siga sus códigos de seguridad eléctrica la bomba este protegido por un fusible de 10 amperios o un local, especialmente los del Código Eléctrico Nacional cortacircuitos. (NEC) y en el lugar de trabajo. El Acta de Seguridad y Salud Ocupacional.
  • Page 14: Pre-Montaje

    Pre-Montaje Aplicación Esta bomba de sumidero sumergible está diseñada para aplicaciones de sumidero de hogar. Únicamentebombeeagua con estabomba. Esta bomba no ha sido probada o aprobada para usar en piscinas o en zonas de agua salada. Y esta bomba tampoco ha sido fabricada para operar continuamente como una "fuente"...
  • Page 15: Contenido Del Paquete

    Pre-Montaje (seguido) CONTENIDO DEL PAQUETE NOTA: Adaptador mostrado no aescala. Parte Descripción Bomba Adaptador de 1-1/4 pg. Especificaciones Voltaje 115V, 60 HZ., 15 Amp Circuit Rango de Temperatura de Líquido 32°F to 77°F(0°- 25°C) Tamaño de descarga NPT Hembra de 1-1/2 pg. o de 1-1/4 pg. Colector de fango Minimo 10 in.
  • Page 16: Montaje

    Montaje CAUTELA: Siempre use la manilla para levantar la bomba. Nunca use el cordón o el cable eléctrico para levantar la bomba. Para evitar quemaduras, desconecte la bomba y permita un tiempo para que la bomba se enfríe después de un largo tiempo de uso. Conexión del tubo de descarga a Instalación de Adaptador la bomba...
  • Page 17: Operación

    Operación PELIGRO: DNo use la bomba o el motor de la bomba con las manos mojadas, o cuando esté de pie sobre la superficie mojada o húmeda, o en agua. Verificación de la Función Conecte el cable de alimentación a una toma de alimentación GFCI de 115V ...
  • Page 18: Cuidado Y Mantenimiento

    Cuidado Y Mantenimiento CAUTELA: Siempre use la manilla para levantar la bomba. Nunca use el cordón o el cable eléctrico para levantar la bomba. Para evitar quemaduras, desconecte la bomba y permita un tiempo para que la bomba se enfríe después de un largo tiempo de uso. Usted Debe Hacer lo Siguiente Usted NO Debe Hacer lo Siguiente Cuando el cable esta desconectado, inspeccione la bomba y...
  • Page 19: Solución De Problemas

    Solución de Problemas Problema Causa Posible Acción Correctiva La bomba no prende o no funciona 1. Fusible fundido 1. Reemplace fusible 2. Salto de interruptor 2. Reajuste el interruptor 3. Enchufe no conectado 3. Asegure el enchufe 4. Enchufeoxidado 4. Limpie las puntas del enchufe 5.
  • Page 20 ?Preguntas, problemas, piezas que faltan? Antes de devolverla a la tienda, llame a Servicio al Cliente de 8:00 AM a 6:00 pm EST de Lunes a Viernes. 1-844-241-5521 HOMEDEPOT.COM...