Download Print this page
Everbilt PCP10001-VSP Use And Care Manual

Everbilt PCP10001-VSP Use And Care Manual

Variable speed pool pump
Hide thumbs Also See for PCP10001-VSP:

Advertisement

Quick Links

Questions, problems, missing parts? Before returning to the store call
Everbilt Customer Service
8 a.m. - 6 p.m., EST, Monday-Friday
1-844-241-5521
HOMEDEPOT.COM

Advertisement

loading

Summary of Contents for Everbilt PCP10001-VSP

  • Page 1 Questions, problems, missing parts? Before returning to the store call Everbilt Customer Service 8 a.m. - 6 p.m., EST, Monday-Friday 1-844-241-5521 HOMEDEPOT.COM...
  • Page 2 GPM of Water @ Total Feet of Lift Max. Lift 0 ft. 10 ft. 20 ft. 30 ft. 40 ft. 50 ft. 3500 72.0 65.0 56.0 44.0 25.0 48 ft. 1000 000 000 2000 39.0 20.0 16 ft. 1200 22.0 7 ft.
  • Page 3 CAUTION: Follow all local electrical and safety codes, along DANGER: Do not pump flammable or explosive liquids such with the National Electrical Code (NEC). In addition, all as oil, gasoline, kerosene, ethanol, etc. Do not use in the Occupational Safety and Health Administration (OSHA) presence of flammable or explosive vapors.
  • Page 4: Tools Required

    IMPORTANT: This pump is made of high-strength, IMPORTANT: Provide sufficient ventilation to maintain air temperature below the maximum ambient temperature rating corrosion-resistant materials. It will provide trouble- shown on the motor nameplate. Any enclosure or pump free service for a long time when properly installed, house must allow adequate ventilation to assure the ambient maintained, and used.
  • Page 5: Specifications

    MATERIALS REQUIRED (NOT INCLUDED) SPECIFICATIONS 230V, 60 HZ., 15 Amp Circuit Power supply 32 to 100° F (0- 38° C) Liquid temp. range 1 -1/2 in. NPT thread with adaptor Discharge size Only qualified, licensed personnel should install pump and wiring. The pump mount must be located away from corrosive or flammable chemicals.
  • Page 6 Fittings Fittings restrict flow; for best efficiency use the fewest number of possible fittings. Avoid fittings which could cause an air trap. Pool fittings must conform to International Association of Plumbing and Mechanical Officials (IAPMO) standards. Use only non-entrapping suction fitting or double suction.
  • Page 7 To Wire a Varier-Speed Motor Be sure power is off. Remove the terminal box lid (FIG.1)  Using muti-function crimping pliers to press o-type grounding terminal which connected 14 AWG. (FIG.2)  Install 1/2” connector to terminal box. Install ground wire to ground rod. using muti-function crimping pliers to connect two wires with two ...
  • Page 8 Table l- Recommended Fusing Data Service to Motor – Distance in Ft. (m) Branch Fuse Motor HP Max Load Amps Voltage/Hz/Phase 0-300’ (0-30) Rating Amps* AWG Wire Size (mm2) 230/60/1 14 (2) 1-1/2 230/60/1 14 (2) * Time delay fuses are recommended instead of standard fuses in any motor circuit. MECHANICAL TROUBLES AND NOISE 1.
  • Page 9 Priming Pump Release all pressure from filter, pump, and piping system; see the filter owner’s manual. In a flooded suction system (water source higher than pump), pump will prime automatically during suction and discharge valves are opened. If the pump is located above the normal pool water level, remove ring and trap assembly, and fill trap and pump with water.
  • Page 10 Operation of Control Panel This series of swimming pool pumps are equipped with human-machine interface, which can display the current time, pump start and stop state, current speed and working mode in real time. You can also set the working mode and current time through the buttons on the panel, where the working mode can be automatic or manual.
  • Page 11 2. Set pump parameters Long press the set key for 3 seconds ↓ Set time mode ↓ Set the time and speed of time period 1 ↓ Set the time and speed of time period 2 ↓ Set the time and speed of time period 3 ↓...
  • Page 12 5. Close/turn on the LCD backlight Press to turn on/off the LCD backing. Press two buttons at the same time until the LCD is off and lights up again. 7. Fault code description : Communication failure. Please check whether the connection line between the display board (upper board) and the drive board (lower board) is loose. :...
  • Page 13 Pump Reassembly/Installing New Seal Ceramic seat must be clean and free of dirt, grease, dust, etc. Wet outer edge with small amount of liquid detergent; press ceramic seat into seal plate cavity firmly and squarely with finger pressure. If ceramic seat will not locate properly, remove it, place face up on bench and re-clean cavity. Ceramic seat should now locate. If seat still will not locate properly, place a cardboard washer over the polished face and use a piece of 3/4 in.
  • Page 14 Read and understand safety and operating instructions in this manual before doing any work on pump! Only qualified personnel should electrically test the pump motor! FAILURE TO PUMP; REDUCED CAPACITY OR DISCHARGE PRESSURE Problem Possible Cause Corrective Action 1. Pump must be primed. Make sure that pump The pump is not priming.
  • Page 15 1-844-241-5521 HOMEDEPOT.COM...

This manual is also suitable for:

Pcp15001-vsp1000 000 000