Basic Operation - CyberPower OL3000RTXL2UHV Owner's Manual

Table of Contents

Advertisement

POWER MODULE FRONT/REAR PANEL DESCRIPTION
1. Power Button / Power on Indicator
Master ON/OFF for the UPS. Indicates that the UPS is on and
supplying power.
2. UPS Status / Fault / Replace Battery LED Indicator
Indicates the status of the UPS, displaying whether it is operating
in Line, Battery or Bypass Mode, if it has an internal fault or if the
battery needs to be replaced.
3. Multifunction LCD Readout
Shows UPS status, information, settings and events.
4. Function Buttons
Scroll up, scroll down, select and cancel LCD menu.
5. Input Circuit Breaker
Provides input overload and fault protection.
6. Battery Backup & Surge Protected Outlets
Provides battery backup and surge protection. They ensure power
is provided to connected equipment over a period of time during a
power failure.
Critical / Noncritical Load
Allows the creation of load priorities to ensure that battery power
reserves are transferred to specified outlets during a power
outage. The unit can be programmed to provide additional
runtime for equipment connected to the "CRITICAL" outlets, while
stopping the power supply to equipment connected to
"NONCRITICAL" outlets after a designated period of time.
7. Serial Port
Serial port provides communication between the UPS and the
computer. The UPS can control the computer's shutdown during a
power outage through the connection while the computer can
monitor the UPS and alter its various programmable parameters.
8. USB port
This is a connectivity port which allows communication and
control between the UPS and the connected computer. It is
recommended to install the PowerPanel® Business Edition Agent
software on the PC/Server connected with the USB cord.
9. Surge Protected Communication Ports RJ-45/RJ-11
These ports are used to protect standard RJ-45/RJ-11 based
products (ADSL, LAN, Phone/ Modem-Lines) and cabling
systems from surges.
10. Relay Output Connector
Convert UPS signals into real potential-free Dry Contacts for
industrial control.
11. Expansion slot
Slot to install optional remote management card.
12. Extended Runtime Battery Module Connector
Connection for additional CyberPower External Battery modules.
13. EPO (Emergency Power Off) Connector
Enables an emergency UPS Power-Off from a remote location.
14. AC Input Inlet
Connect the AC Power cord to a properly wired and grounded
outlet.

BASIC OPERATION

OL1000RTXL2U / OL1500RTXL2U / OL2200RTXL2U / OL3000RTXL2U /
7
Copyright © 2017 CyberPower Systems, Inc.
OL3000RTXL2UHV
OL1000RTXL2U / OL1500RTXL2U
OL2200RTXL2U
OL3000RTXL2U
OL3000RTXL2UHV