Thank you for purchasing a CyberPower product. This UPS is designed to provide unsurpassed power protection, operation, and performance during the lifetime of the product. Please take a few minutes to register your product at: www.CyberPowerSystems.com/registration.
Registration certifes your product's warranty, confrms your ownership in the event of a product loss or theft, and entitles you to free technical support. Register your product now to receive the benefts of CyberPower ownership.
(SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS.
To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive contaminants. (Please see specifcations for acceptable temperature and humidity range).
To reduce the risk of electric shock, do not remove the cover. There are no userserviceable parts inside.
Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected.
The UPS must be connected to an AC power outlet with fuse or circuit breaker protection. Do not plug into an outlet that is not grounded. If you need to de-energize this equipment, turn of and unplug the unit.
To avoid electric shock, turn of the unit and unplug it from the AC power source before installing a computer component.
To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit over current protection in accordance with the National Electric Code, ANSI/NFPA 70.
Not for use in a computer room as defned in the Standard for the Protection of Electronic Computer / Data Processing Equipment, ANSI/NFPA 75.
Do not dispose of batteries in a fre. The batteries may explode.
Do not open or mutilate batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic.
DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT!
CyberPower Systems does not sell products for life support or medical applications. DO NOT use in any circumstance that would afect operation and safety of life support equipment, any medical applications or patient care.
DO NOT USE WITH OR NEAR AQUARIUMS!
To reduce the risk of fire or electric shock, do not use with or near an aquarium. Condensation from the aquarium can cause the unit to short out.
DO NOT USE THE UPS ON ANY TRANSPORTATION!
To reduce the risk of fire or electric shock, do not use the unit on any transportation such as airplanes or ships. The effect of shock or vibration caused during transit and the damp environment can cause the unit to short out.
Inspect the UPS upon receipt.
The box should contain the following:
Problem | Possible Cause | Solution |
Full-time surge protection outlets stop providing power to equipment. Circuit breaker button is projecting from the side of the unit. | Circuit breaker has been tripped due to an overload. | Turn the UPS of and unplug at least one piece of equipment. Reset the circuit breaker by depressing the button, and then turn the UPS on. |
The device does not perform expected runtime | Battery not fully charged. | Recharge the battery by leaving the UPS plugged in. |
Battery is worn out. | Contact CyberPower Systems about replacement batteries at: cyberpowersystems.com/support. | |
The device will not turn on | The on/of switch is designed to prevent damage from rapidly turning it of and on. | Turn the UPS off. Wait 10 seconds and then turn the UPS on. |
The unit is not connected to an AC outlet. | The unit must be connected to a 120V 60Hz outlet. | |
The battery is worn out. | Contact CyberPower Systems about replacement batteries at: cyberpowersystems.com/support. | |
Mechanical problem. | Contact CyberPower Systems at: cyberpowersystems.com/support. | |
The frequency is beyond 47-63Hz | Turn the UPS off. Make sure the frequency range is within 47-63Hz. Or you can turn on with battery mode. | |
PowerPanel Personal is inactive (all icons are gray)*except for SE450G1 | The USB cable is not connected. | Connect the USB cable to the UPS unit and an open USB port on the back of the computer. |
The USB cable is connected to a bad USB port. | Check for a diferent USB port and plug the cable in. | |
The unit is not providing battery power. | Shutdown your computer and turn the UPS off. Wait 10 seconds and turn the UPS back on. This should reset the unit. |
Additional troubleshooting information can be found at "Support" at www.CyberPowerSystems.com
![]() POWER | ![]() ALARM | CONDITION |
On | Of | Normal |
On* | Beep twice every 30 seconds | Utility Failure - Battery Mode – The UPS is providing power to battery power-supplied outlets from its battery. |
On* | Rapid beeping every 1/2 second | Utility Failure - Low Battery – The UPS is providing battery power. Rapid beeping indicates the unit will run out of power soon. |
Of | Constant tone | Overload – Occurs when connected equipment exceeds the rating of battery outlets of the UPS. Turn the UPS of, unplug at least one piece of equipment from battery outlets, reset the circuit breaker and turn the unit on. |
On | Constant tone | Utility Failure – The frequency is beyond 47-63Hz. The UPS will not turn on in line mode. |
* LED will flash when UPS alarm is beeping.
Model | SE450G1 | SX650U | SX950U |
Capacity | 450VA / 260W | 650VA / 360W | 950VA / 510W |
Nominal Input Voltage | 120 Vac | ||
Input Frequency | 50/60 Hz ± 3 Hz | ||
On-Battery Output Voltage | 120Vac ± 5% | ||
On-Battery Output Frequency | 50Hz/60Hz ± 1% (auto-sensing) | ||
Max. Load for UPS Outlets | 450VA / 260W | 650VA / 360W | 950VA / 510W |
Max. Load for Full-Time Surge Protection outlets | 7 Amps | 12 Amps | 12 Amps |
On-Battery Output Wave Form | Simulated Sine Wave | ||
Operating Temperature | + 32°F to 104°F / 0°C to 40°C | ||
Operating Relative Humidity | 0 to 95% non-condensing | ||
Size (W x H x D) | 8.3" x 4.5" x 3.2" 210 x 115 x 81 mm | 9.8" x 5.8" x 3.2" 250 x 147 x 82 mm | 12.2" x 7" x 3.1" 310 x 178 x 80 mm |
Net Weight (lbs / kg) | 3.79 lbs / 1.72 kg | 6.48 lbs / 2.94 kg | 8.70 lbs / 3.95 kg |
Typical Battery Recharge Time | 8 hours typical from total discharge | ||
Typical Battery Life | 3 to 6 years, depending on number of discharge/recharge cycles | ||
Recommended Battery | Sealed Maintenance Free Lead Acid Battery | ||
Safety Approvals | UL1778(UPS), cUL CSA C22.2 No. 107.3-05, FCC/DoC Class B |
Advanced Energy-Saving Design
The GreenPower UPS has a high-efciency charger, which makes it the most energy-efficient UPS in its class. The advanced high-frequency charging system signifcantly improves charging efciency and conserves energy. As a result of this advanced design, the GreenPower UPS uses less energy compared to competitive models. The GreenPower UPS is manufactured in accordance with the Restriction on Hazardous Substances (RoHS) directive making it one of the most environmentally-friendly UPS systems on the market today.
Please visit www.CyberPowerSystems.com for a copy of the Limited Warranty and Connected Equipment Guarantee.
Where Can I Get More Information?
The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded. CyberPower is the warrantor under this Limited Warranty.
For further information please feel free to contact CyberPower at:
Cyber Power Systems (USA), Inc. 4241 12th Ave E., STE 400, Shakopee, MN 55379;
call us at (877) 297-6937; or submit a web ticket online at cyberpowersystems.com/support.
This product can expose you to chemicals including bisphenol A (BPA) and styrene, which is known to the State of California to cause reproductive harm and cancer. For more information, go to www.P65Warnings.ca.gov.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download CyberPower SE450G1, SX650U, SX950U - STANDBY UPS Series Manual