CyberPower SE450G1, SX650U, SX950U - STANDBY UPS Series Manual

CyberPower SE450G1, SX650U, SX950U - STANDBY UPS Series Manual

Also See for SE450G1:

Advertisement

CyberPower SE450G1, SX650U, SX950U - STANDBY UPS Series Manual

FEATURES

FEATURES

  1. Power On Switch
  2. Power On Indicator (green)
  3. Battery and Surge Protected Outlets
  4. Full-Time Surge Protection Outlets
  5. Circuit Breaker
  6. USB Port to PC (except for SE450G1)
  7. USB Charging ports (except for SE450G1)
  8. Widely-Spaced Outlets

PRODUCT REGISTRATION

Thank you for purchasing a CyberPower product. This UPS is designed to provide unsurpassed power protection, operation, and performance during the lifetime of the product. Please take a few minutes to register your product at: www.CyberPowerSystems.com/registration.
Registration certifes your product's warranty, confrms your ownership in the event of a product loss or theft, and entitles you to free technical support. Register your product now to receive the benefts of CyberPower ownership.

IMPORTANT SAFETY WARNINGS

(SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS.

burn hazardburn hazard
To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive contaminants. (Please see specifcations for acceptable temperature and humidity range).


To reduce the risk of electric shock, do not remove the cover. There are no userserviceable parts inside.


Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected.


The UPS must be connected to an AC power outlet with fuse or circuit breaker protection. Do not plug into an outlet that is not grounded. If you need to de-energize this equipment, turn of and unplug the unit.


To avoid electric shock, turn of the unit and unplug it from the AC power source before installing a computer component.


To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit over current protection in accordance with the National Electric Code, ANSI/NFPA 70.


Not for use in a computer room as defned in the Standard for the Protection of Electronic Computer / Data Processing Equipment, ANSI/NFPA 75.


Do not dispose of batteries in a fre. The batteries may explode.


Do not open or mutilate batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic.

DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT!
CyberPower Systems does not sell products for life support or medical applications. DO NOT use in any circumstance that would afect operation and safety of life support equipment, any medical applications or patient care.

burn hazardshock hazard
DO NOT USE WITH OR NEAR AQUARIUMS!
To reduce the risk of fire or electric shock, do not use with or near an aquarium. Condensation from the aquarium can cause the unit to short out.

burn hazardshock hazard
DO NOT USE THE UPS ON ANY TRANSPORTATION!
To reduce the risk of fire or electric shock, do not use the unit on any transportation such as airplanes or ships. The effect of shock or vibration caused during transit and the damp environment can cause the unit to short out.

INSTALLING YOUR DEVICE

UNPACKING

Inspect the UPS upon receipt.
The box should contain the following:

  1. UPS unit
  2. User's manual
  3. USB device cable (except for SE450G1)

DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT

  1. Ensure that the equipment plugged into the outlet does not exceed the UPS unit's rated capacity (450VA/260W for SE450G1, 650VA/360W for SX650U, and 950VA/510W for SX950U). If the rated capacities of the unit are exceeded, an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip.
  2. There are many factors that can afect the amount of power that your electronic equipment will require. For optimal system performance keep the load below 80% of the unit's rated capacity.

HARDWARE INSTALLATION GUIDE

  1. Your new UPS may be used immediately upon receipt. However, after receiving a new UPS, to ensure the battery's maximum charge capacity, it is recommended that you charge the battery for at least 8 hours. Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, the battery will automatically charge whether the UPS is turned on or turned off.
  2. With the UPS unit turned of and unplugged, connect your equipment requiring battery backup into the battery power supplied outlets. Plug the other peripheral equipment (printer, scanner, speakers) into the full-time surge protection outlets. DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump or other large electrical device into the "Battery and Surge Protected Outlets". The power demands of these devices will overload and possibly damage the unit.
  3. Plug the UPS into a 2-pole, 3-wire grounded receptacle (wall outlet). Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air conditioner, refrigerator, copier, etc...). The warranty prohibits the use of extension cords, outlet strips, and surge strips.
    Connecting the device to a 3-wire grounded outlet
  4. Press the power switch to turn the unit on. The Power On indicator light will illuminate green and the unit will "beep" twice.
  5. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS of and unplug at least one piece of equipment from the battery power supplied outlets. Make sure the circuit breaker is depressed and then turn the UPS on.
  6. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
  7. To store the UPS for an extended period of time, cover it and store with the battery fully charged. While in storage, recharge the battery every three months to ensure optimal battery life.
  8. Ensure the wall outlet and UPS are located near the equipment being attached for proper accessibility.
  9. Lay the UPS horizontally or use the keyhole mounting slots to afx the UPS to the wall in the proper orientation. DO NOT stand the UPS up vertically.

BASIC OPERATION

  1. Power On Switch
    To turn the UPS on, press the power button for approximately 2 seconds - you will hear a constant tone (1 second) - and release after a short beep.
    To turn the UPS off, press the power button for approximately 2 seconds - you will hear a constant tone (1 second) - and release after two short beeps.
    Alarm setting: The audible alarm can be turned OFF or ON by quickly pressing the POWER button twice. The default setting is for the Alarm On. To turn the Alarm Off, quickly press the power button twice. You will hear two short beeps when the Alarm is turned off. To turn the Alarm back ON, quickly press the power button twice. You will hear a single short beep when the Alarm is turned on.
    *When the Alarm is turned off, there will be no audible notifcation when the UPS reaches a low battery state.
  2. Power On Indicator (green)
    This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and spikes.
  3. Battery and Surge Protected Outlets
    The unit has several battery powered and surge protected outlets to ensure temporary uninterrupted operation of your equipment during a power failure. (DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum cleaner, sump pump, or other large electrical device into the "Battery and Surge Protected Outlets." The power demands of these devices will overload and possibly damage the unit.)
  4. Full-Time Surge Protection Outlets
    The unit has several surge suppression outlets.
  5. Circuit Breaker
    Located on the side of the UPS, the circuit breaker serves to provide overload and fault protection.
  6. USB Port to PC (except for SE450G1)
    The port allows connection and communication between the USB port on the computer and the UPS unit. The UPS communicates its status to the PowerPanel® Personal software.
  7. USB Charging ports (except for SE450G1)
    The USB charging ports provide 5V 2.1A power output.
  8. Widely-Spaced Outlets
    The UPS unit has four widely-spaced outlets, so AC power adapters can be plugged into the UPS without overlapping or blocking adjacent outlets.

SYSTEM FUNCTION BLOCK DIAGRAM

SYSTEM FUNCTION BLOCK DIAGRAM

TROUBLESHOOTING

Problem Possible Cause Solution
Full-time surge protection outlets stop providing power to equipment. Circuit breaker button is projecting from the side of the unit. Circuit breaker has been tripped due to an overload. Turn the UPS of and unplug at least one piece of equipment. Reset the circuit breaker by depressing the button, and then turn the UPS on.

The device does not perform expected runtime

Battery not fully charged. Recharge the battery by leaving the UPS plugged in.
Battery is worn out. Contact CyberPower Systems about replacement batteries at: cyberpowersystems.com/support.

The device will not turn on

The on/of switch is designed to prevent damage from rapidly turning it of and on. Turn the UPS off. Wait 10 seconds and then turn the UPS on.
The unit is not connected to an AC outlet. The unit must be connected to a 120V 60Hz outlet.
The battery is worn out. Contact CyberPower Systems about replacement batteries at: cyberpowersystems.com/support.
Mechanical problem. Contact CyberPower Systems at: cyberpowersystems.com/support.
The frequency is beyond 47-63Hz Turn the UPS off. Make sure the frequency range is within 47-63Hz. Or you can turn on with battery mode.

PowerPanel Personal is inactive (all icons are gray)

*except for SE450G1
The USB cable is not connected. Connect the USB cable to the UPS unit and an open USB port on the back of the computer.
The USB cable is connected to a bad USB port. Check for a diferent USB port and plug the cable in.
The unit is not providing battery power. Shutdown your computer and turn the UPS off. Wait 10 seconds and turn the UPS back on. This should reset the unit.

Additional troubleshooting information can be found at "Support" at www.CyberPowerSystems.com

DEFINITIONS FOR LED INDICATORS & AUDIBLE ALARMS


POWER

ALARM
CONDITION
On Of Normal
On* Beep twice every 30 seconds Utility Failure - Battery Mode – The UPS is providing power to battery power-supplied outlets from its battery.
On* Rapid beeping every 1/2 second Utility Failure - Low Battery – The UPS is providing battery power. Rapid beeping indicates the unit will run out of power soon.
Of Constant tone Overload – Occurs when connected equipment exceeds the rating of battery outlets of the UPS. Turn the UPS of, unplug at least one piece of equipment from battery outlets, reset the circuit breaker and turn the unit on.
On Constant tone Utility Failure – The frequency is beyond 47-63Hz. The UPS will not turn on in line mode.

* LED will flash when UPS alarm is beeping.

TECHNICAL SPECIFICATIONS

Model SE450G1 SX650U SX950U
Capacity 450VA / 260W 650VA / 360W 950VA / 510W
Nominal Input Voltage 120 Vac
Input Frequency 50/60 Hz ± 3 Hz
On-Battery Output Voltage 120Vac ± 5%
On-Battery Output Frequency 50Hz/60Hz ± 1% (auto-sensing)
Max. Load for UPS Outlets 450VA / 260W 650VA / 360W 950VA / 510W
Max. Load for Full-Time Surge Protection outlets 7 Amps 12 Amps 12 Amps
On-Battery Output Wave Form Simulated Sine Wave
Operating Temperature + 32°F to 104°F / 0°C to 40°C
Operating Relative Humidity 0 to 95% non-condensing
Size (W x H x D) 8.3" x 4.5" x 3.2"
210 x 115 x 81 mm
9.8" x 5.8" x 3.2"
250 x 147 x 82 mm
12.2" x 7" x 3.1"
310 x 178 x 80 mm
Net Weight (lbs / kg) 3.79 lbs / 1.72 kg 6.48 lbs / 2.94 kg 8.70 lbs / 3.95 kg
Typical Battery Recharge Time 8 hours typical from total discharge
Typical Battery Life 3 to 6 years, depending on number of discharge/recharge cycles
Recommended Battery Sealed Maintenance Free Lead Acid Battery
Safety Approvals UL1778(UPS), cUL CSA C22.2 No. 107.3-05, FCC/DoC Class B

CYBERPOWER GREENPOWER UPS TECHNOLOGY

Advanced Energy-Saving Design
The GreenPower UPS has a high-efciency charger, which makes it the most energy-efficient UPS in its class. The advanced high-frequency charging system signifcantly improves charging efciency and conserves energy. As a result of this advanced design, the GreenPower UPS uses less energy compared to competitive models. The GreenPower UPS is manufactured in accordance with the Restriction on Hazardous Substances (RoHS) directive making it one of the most environmentally-friendly UPS systems on the market today.

LIMITED WARRANTY AND CONNECTED EQUIPMENT GUARANTEE

Please visit www.CyberPowerSystems.com for a copy of the Limited Warranty and Connected Equipment Guarantee.

Where Can I Get More Information?
The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded. CyberPower is the warrantor under this Limited Warranty.

For further information please feel free to contact CyberPower at:
Cyber Power Systems (USA), Inc. 4241 12th Ave E., STE 400, Shakopee, MN 55379;
call us at (877) 297-6937; or submit a web ticket online at cyberpowersystems.com/support.


This product can expose you to chemicals including bisphenol A (BPA) and styrene, which is known to the State of California to cause reproductive harm and cancer. For more information, go to www.P65Warnings.ca.gov.

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download CyberPower SE450G1, SX650U, SX950U - STANDBY UPS Series Manual