Model
Configuration
Capacity (VA)
Capacity (Watts)
Form Factor
Energy-saving Technology
Input
Input Power Plug
Input Voltage Range
Input Frequency Range
Input Power Factor
Cold Start
Output
Output Waveform
Output Voltage (Configurable)
Output Frequency
Transfer Time (Typical)
Rated Power Factor
Harmonic Distortion
Crest Factor
ECO Mode Bypass Voltage Range
UPS Outlets
Protection
Surge Protection
Phone / Network Surge Protection
Overload Protection
Short Circuit Protection
Battery
Specifications
Recharge Time 0-90% (Typical)
Sealed, Maintenance Free
Hot-Swappable
Status Indicators
LCD Screen
LED Indicators
Audible Alarms
Environment
Operating Temperature
Operating Relative Humidity
Management
On-Device Features
Connectivity Ports
Expansion Slot
Software
Power Management Software
Physical
Dimensions
Net Weight
Safety
Conformance Approvals
1
For OL1500/2200/3000RTXL2U, 100V is derated by 20%, 110/115V is derated by 10%

TECHNICAL SPECIFICATIONS

OL1000RTXL2U
OL1500RTXL2U
1000VA
1500VA
900W
1350W
≧94%
NEMA 5-15P
100, 110, 115, 120, 125Vac ±2%
50 / 60Hz (Auto-Sensing or Configurable) ±0.25Hz
0.9
0.9
THD < 3% at Linear Load, < 5% at Non-linear Load
(8) NEMA 5-15R
1780 Joules
Line Mode:
105~125% Load for 1 min,
Battery Mode: 105~130% Load for 10 sec,
UPS Output Cut off Immediately or Input Fuse / Circuit Breaker Protection
(3) 12V/9AH
Multi-Function LCD Readout that Supports:
Multi-Language Interface,
(25) Types of Function Setting,
Power On (White),
Bypass Mode (Yellow), Fault (Red),
Battery Mode, Battery Low, Overload, UPS Fault
Start-up Self Test, Auto-Charge, Auto-Restart, Auto-Overload Recovery
(1) Serial Port (RS232), (1) USB Port, (1) Relay Out
(1) Expansion Slot for optional remote management cards
L x W x H = 16.9 x 17 x 3.5in.
(43 x 43.3 x 8.8cm)
39.6lbs(18Kg)
CE, UL1778, FCC part 15 Class B
15
OL2200RTXL2U
2200VA
1800W
Rackmount / Tower
Yes, ECO Mode Efficiency
≧95%
NEMA 5-20P
100~125Vac
50 / 60Hz
0.99
Yes
Sine wave
1
0ms
0.82
3 : 1
±10%, ±15% (Configurable)
(6) NEMA 5-20R,
(1) L5-20R
IEC 61000-4-5 Level 3
RJ11/RJ45 (One In/One Out)
126~150% Load for 10 sec
131~150% Load for 2 sec
4 hours (0~90%)
Yes
Yes
(23) Types of Read Out,
(5) Event Logs
Line Mode (Green),
32°F to 104°F (0℃ to 40℃)
0 to 90% Non-Condensing
®
PowerPanel
Business Edition
L x W x H = 23.6 x 17 x 3.5in.
CE, UL1778, FCC part 15 Class A
Copyright © 2017 CyberPower Systems, Inc.
OL3000RTXL2U
OL3000RTXL2UHV
3000VA
3000VA
2700W
2700W
≧97%
NEMA L5-30P
NEMA L6-20P
200~240Vac
200, 208, 220,
230, 240Vac ±2%
0.9
(6) NEMA 5-20R,
(2) NEMA L6-20R,
(1) L5-30R
(1) NEMA L6-30R
1335 Joules
(6) 12V/9AH
Battery Mode (Yellow),
Replace Battery (Red)
(60 x 43.3 x 8.8cm)
68.2lbs(31Kg)
0.9