POWER MODULE FRONT/REAR PANEL DESCRIPTION
1. Power Button / Power on Indicator
Master ON/OFF for the UPS. Indicates that the UPS is on and supplying
power.
2. UPS Status / Fault / Replace Battery LED Indicator
Indicates the status of the UPS, displaying whether it is operating in Line,
Battery or Bypass Mode, if it has an internal fault or if the battery needs
to be replaced.
3. Multifunction LCD Readout
Shows UPS status, information, settings and events.
4. Function Buttons
Scroll up, scroll down, select and cancel LCD menu.
5. Input Circuit Breaker
Provides input overload and fault protection.
6. Battery Backup & Surge Protected Outlets
Provides battery backup and surge protection. They ensure power is
provided to connected equipment over a period of time during a power
failure.
Critical / Noncritical Load
Allows the creation of load priorities to ensure that battery power
reserves are transferred to specified outlets during a power outage. The
unit can be programmed to provide additional runtime for equipment
connected to the "CRITICAL" outlets, while stopping the power supply to
equipment connected to "NONCRITICAL" outlets after a designated
period of time.
Copyright © 2014 CyberPower Systems, Inc.

BASIC OPERATION

OL1000XL / OL1500XL
7. Serial Port
Serial port provides communication between the UPS and the computer.
The UPS can control the computer's shutdown during a power outage
through the connection while the computer can monitor the UPS and alter
its various programmable parameters.
8. USB port
This is a connectivity port which allows communication and control
between the UPS and the connected computer. It is recommended to
install the PowerPanel® Business Edition Agent software on the
PC/Server connected with the USB cord.
9. Surge Protected Communication Ports RJ-45/RJ-11
These ports are used to protect standard RJ-45/RJ-11 based products
(ADSL, LAN, Phone/ Modem-Lines) and cabling systems from surges.
10. Relay Output Connector
Convert UPS signals into real potential-free Dry Contacts for industrial
control.
11. SNMP/HTTP Network slot
Slot to install the optional SNMP card for remote network control and
monitoring.
12. Extended Runtime Battery Module Connector
Connection for additional CyberPower XL Battery modules.
13. EPO (Emergency Power Off) Connector
Enables an emergency UPS Power-Off from a remote location.
14. AC Input Inlet
Connect the AC Power cord to a properly wired and grounded outlet.