4. SPECIFICATIONS

Color
Thermostatic control
Door type
Glass type
Air return plenum – dimensions (Depth or Height)
Air return plenum – dimension (Width)
Hot air plenum – dimensions (Depth or Height)
Hot air plenum – dimension (Width)
Ash pan – dimensions (Width x Depth x Height)
Clearance – front
Clearance – back wall
Clearance – side wall
Clearance – opposite side wall
Clearances – ducts
Clearance – recommended for maintenance on
option side
Wood Add-on – location of the connection with
existing furnace
Wood Add-on – air inlet duct dimensions (Height X
Width)
Burner – efficiency
Burner – standard
Burner – other brands approved
Burner – location
Burner – recommended clearance for maintenance
Burner – Mandatory connector pipe diameter
(Wood-oil)
Burner – Mandatory exhaust pipe diameter
Burner – location of exhaust pipe
Burner – capacity at input #1
Burner – orifice at input #1
Burner – pump pressure at input #1
Electric element – location
Electric element – clearance recommended for
maintenance
Electric element – recommended (maximum
output)
Electric element – other optional (maximum output)
Top cold air plenum option – material
Top cold air plenum option – dimensions (Width x
Depth x Height)
Top cold air plenum option – smoke pipe diameter
Fresh air intake adapter option
Fresh air intake adapter – connection location
Tested and listed as per applicable standards
Warranty
* US Gallon (1 US Gallon = 0,83 Imperial Gallon)
8
Grey
Yes
Single, glass with cast iron frame
Ceramic glass
15 3/4 in
24 3/4 in
28 5/8 in
24 1/2 in
12 in x 16 in x 3 in
48 in
24 in from the blower housing recommended service clearance
6 in without options installed
24 in recommended service clearance
6 in for the first 6 feet and 1 in after
24 in
Left or right
14 1/2" X 22"
Beckett AFG : 85 % / Riello : 87%
Beckett AFG
Riello
Left or right
24 in
7 in
5 in
Left or right
90,000 BTU (26,4 kW)
0,55 gal/h* X 60° W (2,08 L/h)
140 PSI
Left or right
24 in
18 kW
15 kW or 20 kW
Galvanized steel
24 7/8"W x 15 7/8"D x 12 7/8"H
6 in
5 in
Left or right
By an accredited laboratory (CAN/USA)
Limited lifetime