19.1. VALIDATING STATUS

When using your furnace, you can validate at any time, the status of any of the following components:

Distribution blower

Air damper

Temperature probe (RTD)

19.1.1. DISTRIBUTION BLOWER
To check the status of the distribution blower, go to the main menu under "TROUBLESHOOT LINK" then go to page 5.
When the fan is on, the selected speed is black.
19.1.2. AIR DAMPER
To check the status of the air damper, go to the main menu under "TROUBLESHOOT LINK" then go to page 3. When
the furnace is in wood heating, the damper is open. The green square next to "DAMPER" should be on the left, (closed
circuit). When another heating mode is on, the damper is closed, so the circuit is open and the green square is on the
right.
19.1.3. TEMPERATURE PROBE (RTD)
The temperature probe continuously reads the temperature in the plenum and displays it on the main page in the upper
right corner. If the probe fails, the error message "PLENUM OVERTEMP" will appear.