Appliance Start-Up; Prolonged Closing; Technical Data; Uh -Caddy - CADDY PF01015 Installation And Operating Instructions Manual

Table of Contents

Advertisement

28.7.

APPLIANCE START-UP

The start-up must be performed by a qualified technician. Make sure the installation is completed and the
oil tank has been filled up. The oil line must also have been purged.
CAUTION: CLOSE THE BLOWER COMPARTMENT ACCESS PANEL BEFORE STARTING THE
BURNER.
To change the kick-in point (AUX KIP) temperature of the fan in oil mode, go in SETUP, OPTIONS,
CONFIGURATION.
The temperature at which the fan shuts off (TEMP OFF) is unique for all heating systems. To change it, go
to SETUP, then WOOD SETUP.
28.8.

PROLONGED CLOSING

Cut off the electric circuit
Close the oil shut-off valve
NOTE: THE SHUT-OFF VALVE MUST BE CLOSED WHEN THE APPLIANCE IS OUT OF
SERVICE FOR A PROLONGED PERIOD OF TIME.

29. TECHNICAL DATA

29.1. UH –CADDY
BURNER
BTU
MODEL
TYPE
INPUT
UH–
BECKETT AFG
90,000
CADDY
UH–
RIELLO 40 F3
91,000
CADDY
For any additional information, consult the rating plate on the left hand side of the appliance.
76
NOZZLE
FLOW
HEAD
0
0.55 X 60
W
0.55 GAL US/H
L2
(DELAVAN)
(2.08 L-H)
0
0.50 X 70
W
0.60 GAL US/H
---
(DELAVAN)
(2.27 L-H)
STATIC
PRESSURE
H.P. FAN
PLATE
AT THE PUMP
MOTOR
140 PSI
YES
1/3
(965 kPa)
150 PSI
---
1/3
(1035 kPa)
TUBULATOR
AIR
ADJUSTMENT
ADJUSTMENT
---
0/2
1
2.5
EFFICIENCY
85%
87%

Hide quick links: