4. SPECIFICATIONS

Color
Thermostatic control
Door type
Glass type
Air return plenum – dimensions (Depth or Height)
Air return plenum – dimension (Width)
Hot air plenum – dimensions (Depth or Height)
Hot air plenum – dimension (Width)
Ash pan – dimensions (Width x Depth x Height)
Clearance – front
Clearance – back wall
Clearance – side wall
Clearance – opposite side wall
Clearances – ducts
Clearance – recommended for maintenance on
option side
Burner – efficiency
Burner – standard
Burner – other brands approved
Burner – location
Burner – recommended clearance for maintenance
Burner – mandatory connector pipe diameter
(Wood-oil)
Burner – mandatory exhaust pipe diameter
Burner – location of exhaust pipe
Burner – capacity at input #1 / #2 Beckett
Burner – orifice at input #1 / #2 Beckett
Burner – pump pressure at input #1 / #2 Beckett
Burner – capacity at input #1 / #2 Riello
Burner – orifice at input #1 / #2 Riello
Burner – pump pressure at input #1 / #2 Riello
Electric element – location
Electric element – clearance recommended for
maintenance
Electric element – recommended (maximum
output)
Electric element – other optional (maximum output)
Top cold air plenum option – material
Top cold air plenum option – dimensions
(Width x Depth x Height)
Top cold air plenum option – smoke pipe diameter
Fresh air intake adapter option
Fresh air intake adapter – connection location
Fresh air intake adapter – connecting pipe
diameter
Tested and listed as per applicable standards
Warranty
* US Gallon (1 US Gallon = 0,83 Imperial Gallon)
8
Grey
Yes
Single, glass with cast iron frame
Ceramic glass
17 15/16 in
19 15/16 in
32 1/8 in
25 3/8 in
11 15/16 in x 19 5/8 in x 2 5/8 in
48 in
24 in from the blower housing recommended service clearance
6 in without options installed
24 in recommended service clearance
6 in for the first 6 feet with heat shield and 1 in after
24 in
Beckett AFG : 85 % / Riello : 87%
Beckett AFG
Riello
Left or right
24 in
7 in
5 in
Left or right
91,000 BTU (27 kW) / 120,000 Btu (35 KW)
0,65 gal/h* 70° W (2,46 l/h) for both inputs
100 PSI / 175 PSI
91,000 BTU (27 kW) / 120,000 Btu (35 KW)
0.50 gal/h* 70° W (1.89 l/h) / 0.65 gal/h* 70° W (2.46 l/h)
150 PSI / 165 PSI
Left or right
24 in
20 kW
25 kW
Galvanized steel
20 in x 18 in x 17 1/4 in
6 in
5 in
Left or right
6 in
By an accredited laboratory (CAN/USA)
Limited lifetime