30. MAINTENANCE

At the beginning of heating season, have the complete installation inspected by a qualified service man,
especially the lighting system and the controls.
NOTE: THE UNIT'S MAINTENANCE, REPAIRS AND THE CLEANING OF
THE OIL FILTER MUST BE DONE BY A QUALIFIED TECHNICIAN.
30.1. MAINTENANCE
WARNING: TURN OFF ELECTRIC POWER SUPPLY BEFORE SERVICING THE UNIT.
1. The furnace, the burner and the flue pipe should be cleaned at least once a year.
2. The nozzle should be inspected and replaced if needed.
3. Handle the nozzle with care to avoid damaging its surface.
4. The electrodes should be adjusted as indicated in the burner manual.
5. Lubricate the burner motor bearings twice a year. (2 or 3 drops of SAE 20 non-detergent
lubricating oil).
6. The oil filter should be verified annually and replaced if needed.

30.2. SERVICE

Before calling for service, first check the following
Fuel supply
Electric fuses or breakers
Thermostat setting
PC board settings
The state of the green diagnostic LED on the burner control.
Burner no.: _______________ Model: _____________ Date of installation: _________________
Service telephone no.: Day: ______________________ Night: ___________________________
Dealer's name and address: _______________________________________________________
TEST REPORT:
CO
_______% Temp. at stack: ______________ Draft at stack: ________IN.W.C.
2
Nozzle output: _______________GPH
Inspected by : _______________________________________________________

30.3. FILTERS

See Section 17.5 - FILTERS
Smoke colour: ______________________