23.7.

APPLIANCE START-UP

The start-up must be performed by a qualified technician. Make sure the installation is completed and the oil tank has
been filled up. The oil line must also have been purged.
CAUTION:
CLOSE THE BLOWER COMPARTMENT ACCESS PANEL BEFORE STARTING THE BURNER.
23.8.

PROLONGED CLOSING

A) Cut off the electric circuit
B) Close the oil shut-off valve
NOTE: THE SHUT-OFF VALVE MUST BE CLOSED WHEN THE APPLIANCE IS OUT OF SERVICE FOR A
PROLONGED PERIOD OF TIME.

24. TECHNICAL DATA

24.1. UH –MAX CADDY
BURNER
BTU
MODEL
TYPE
INPUT
UH–
MAX
BECKETT AFG
91,000
CADDY
UH–
MAX
BECKETT AFG
120,000
CADDY
UH–
MAX
RIELLO 40 F3
91,000
CADDY
UH–
MAX
RIELLO 40 F3
120,000
CADDY
For any additional information, consult the rating plate on the left hand side of the appliance.

25. MAINTENANCE

At the beginning of heating season, have the complete installation inspected by a qualified service man,
especially the lighting system and the controls.
NOTE: THE UNIT'S MAINTENANCE, REPAIRS AND THE CLEANING OF
THE OIL FILTER MUST BE DONE BY A QUALIFIED TECHNICIAN.
.
25.1. MAINTENANCE
WARNING: TURN OFF ELECTRIC POWER SUPPLY BEFORE SERVICING THE UNIT.
1. The furnace, the burner and the flue pipe should be cleaned at least once a year.
2. The nozzle should be inspected and replaced if needed.
3. Handle the nozzle with care to avoid damaging its surface.
4. The electrodes should be adjusted as indicated in the burner manual.
5.
Lubricate the burner motor bearings twice a year. (2 or 3 drops of SAE 20 non detergent lubricating oil).
6. The oil filter should be verified annually and replaced if needed.
NOZZLE
FLOW
HEAD
0
0.65, 70
W
0.65 GAL US/H
F0
(DELAVAN)
(2.46 L-H)
0
0.65, 70
W
0.86 GAL US/H
F0
(DELAVAN)
(3.26 L-H)
0
0.50, 70
W
0.60 GAL US/H
---
(DELAVAN)
(2.27 L-H)
0
0.65, 70
W
0.84 GAL US/H
---
(DELAVAN)
(3.18 L-H)
STATIC
PRESSURE
H.P. FAN
PLATE
AT THE PUMP
MOTOR
100 PSI
---
1/2
(690 kPa)
175 PSI
---
1/2
(1205 kPa)
150 PSI
---
1/2
(1035 kPa)
165 PSI
---
1/2
(1135 kPa)
TUBULATOR
AIR
ADJUSTMENT
ADJUSTMENT
---
0/7
---
1/6
1
2.5
1
2.5
EFFICIENCY
85%
83%
87%
85%
59