PICTURE MENU
DEINTERLACE
ON
OFF
NOISE REDUCTION
VIDEO input only
TELECINE
HDMI1, HDMI2, VIDEO, VGA (YPbPr),
MP inputs only
ADAPTIVE CONTRAST*
2
HDMI1, HDMI2, VIDEO, VGA (YPbPr),
MP inputs only
UNIFORMITY
*2
ROTATION
IMAGE FLIP
NONE
H FLIP
V FLIP
180° ROTATE
OSD FLIP
SPECTRAVIEW ENGINE
NUMBER OF PICT. MODES
METAMERISM
COLOR STABILIZER
CALIBRATION
RESET
*
2
: This function is available when [SPECTRAVIEW ENGINE] is set to [OFF].
Selects the IP (Interlace to Progressive) conversion function.

NOTE:
[IMAGE FLIP] is not available.
 •
When [SUPER] is selected in [INPUT CHANGE] and displayed, this function cannot be
changed.
Converts interlaced signals to progressive. Depending on the movie, images may flicker. This is the default
setting.
Disables IP conversion. This setting is best suited for motion pictures, but increases the risk of image
retention.
Adjusts the amount of noise reduction. Press + button or - button to adjust.
Automatically senses the sources frame rate for optimal picture quality.
AUTO: It automatically detects images of 24 frames/sec such as movies, and reduces flicker of images.
When selecting [AUTO], please set [DEINTERLACE] to [ON].
OFF: Try if the motion of the image is unnatural.
Sets the level of adjustment for dynamic contrast.
If HIGH is set, the image is displayed clearly but it makes brightness unstable due to the wide gap in
contrast variation.
Improves the color reproduction and evens out the non-uniformity in luminance of the monitor.
Changes the orientation of the image to left/right, up/down, or rotated.
Press + button or - button to select.
NOTE: This function is not available when MOTION in [SCREEN SAVER] is [ON].

NOTE:
When the [ASPECT] is set to [DYNAMIC], the image will be changed to [FULL] before
[ROTATE] starts.
 •
When an IMAGE FLIP option is selected, except for [NONE], the following functions
are disabled: [MULTI PICTURE MODE], [TEXT TICKER], [STILL], [POINT ZOOM] and
[TILE MATRIX].
 •
When the input signal is interlaced, the image may be distorted.
Normal mode.
Flips the image left/right.
Flips the image up/down.
Rotates the image 180 degrees.
Determines the OSD menu direction.
If [ON] is selected, the OSD orientation will be adjusted based on the selection for [IMAGE FLIP].
Select [ON] to activate [SPECTRAVIEW ENGINE] (see
Limits the number of selectable Picture Modes.
Limiting the number of selectable Picture Modes can be used for the following purposes:
Locking
By setting to [1], it will prevent other Picture Modes from being accessed and adjusted.
Skip
If there are unused Picture Modes that aren't needed, they can be skipped when using the Picture
Mode button on the remote control to toggle modes. For example, if [3] is set for [NUMBER OF PICT.
MODES], the available picture modes are [1, 2, 3] and the other modes will be skipped.
Improves the white point color matching when the display is used side-by-side with a standard gamut
display monitor. This feature compensates for the way the human eye perceives colors slightly differently
compared to the scientific instrument used to adjust the display during calibration. This function should be
disabled in color critical applications.
Uses the internal color sensor to compensate for a natural color shift that occurs with age.
Starts the "Stand-Alone Calibration" when using a USB color sensor.
Resets all PICTURE settings back to factory settings except for [SPECTRAVIEW ENGINE].