Inverter Software Required - Fronius Datamanager 2.0 Operating Instructions Manual

Hide thumbs Also See for Datamanager 2.0:
Table of Contents

Advertisement

These specifications do not provide an absolute guarantee of flawless operation.
High error rates in the transmission, reception fluctuations, or connection dropouts can
have an adverse effect on Fronius Datamanager 2.0's online operation.
Fronius recommends on-site testing to ensure that the connections meet the minimum
requirements.
For operation with an antenna extension.
If you want to connect your inverter(s) to the internet using WLAN, we recommend the
following approach:
-
-
Since the Fronius Datamanager 2.0 acts as a datalogger, no other datalogger may be
present in the Fronius Solar Net ring.
There must only be one Fronius Datamanager 2.0 for each Fronius Solar Net ring.
The Fronius Datamanager 2.0 must be in secondary mode if installed in Fronius Galvo
and Fronius Symo inverters.
The following DATCOM components must not be operated together with Fronius
Datamanager 2.0 in a Fronius Solar Net ring:
-
-
-
-
-
-
-
To use the Fronius Datamanager 2.0
-
-
The Fronius Datamanager 2.0 plug-in card and the Fronius Com Card must not be used
together in one inverter.
Inverter software
Fronius Datamanager 2.0 requires the following inverter software versions for its opera-
required
tion:
Inverter
Fronius IG 15–60
Fronius IG 2000–5100
Fronius IG 300–500
Fronius IG Plus 35–
150
Fronius IG TL *
Fronius CL
Fronius Agilo *
10
Test your signal strength in the exact position where the inverter is to be installed
and make sure the Datamanager 2.0 card is activated.
Connect to the WLAN network using a smartphone, laptop, or tablet, and test the
connection.
The free website "www.speedtest.net" can be used to check whether the connection
meets our recommended download speed of at least 512 kbit/s and an upload
speed of 256 kbit/s.
Fronius Power Control Card/Box
Fronius Modbus Card
Fronius Datalogger Web
Fronius Personal Display DL Box
Fronius Datalogger easy/pro
Fronius Datamanager
Fronius Datamanager 2.0 Box
the plug-in card must be installed in an inverter,
or
there must be a Fronius Datamanager Box 2.0 in the Fronius Solar Net ring.
required software version according to display
(MainControl)
V2.9.4 or higher
starting from series no 19153444
V3.6.4.0 or higher
V4.22.00 or higher
-
V4.22.00 or higher
-