7-2. ERROR CODES

DISPLAY
"E-4"
Control board overheating
"E-5"
"E-6A"
Temperature probe open
"E-6B"
Temperature probe shorted
"E-10"
"E-15"
"E-18-A"
"E-18-B"
"E-18-C"
Aug. 2011
In the event of a control system failure, the digital display
shows an error message. The message codes are shown in the
DISPLAY column below. A constant tone is heard when an er-
ror code is displayed, and to silence this tone, press any button.
CAUSE
Oil overheating
High limit
Drain switch
Left level sensor open
Right level sensor open
Both level sensors open
CORRECTION
Turn switch to OFF position, then turn switch back
to ON; if display shows "E-4", the control board is
getting too hot; check the louvers on each side of the
unit for obstructions
Turn switch to OFF position, then turn switch back to
ON; if display shows "E-5", the heating circuits and
temperature probe should be checked
Turn switch to OFF position, then turn switch back to
ON; if display shows "E-6A", the temperature probe
should be checked
Turn switch to OFF position, then turn switch back to
ON; if display shows "E-6B", the temperature probe
should be checked
Let unit cool down (15-20 minutes), using the high limit
tool on the inside of the LH door and gently pushing it
into the hole in the heating element hinge; if high limit
does not reset, high limit must be replaced
Make sure drain knob is completely pushed-in; if E-15
persists, have drain switch checked
Turn switch to OFF position, then turn switch back to
ON; if display still indicates a failed sensor, have the
connections checked the control board; have sensor
checked & replaced if necessory