  • Page 2 0 Index 1 Product overview 2 Family models 3 Application areas ULTRASONIC PORTABLE to NMEA 0183 ULTRASONIC PORTABLE to NMEA 2000 ULTRASONIC Wired or ULP to BLE and to NMEA 2000 Flexible interfaces 4 Package content 5 Functionalities POWER 5.2. NMEA 2000®...
  • Page 3 8 Configuration WIFI STATION CONFIGURATION, and IP CONFIGURATION BLE CONFIGURATION NMEA 0183 CONFIGURATION 9 Technical specifications 10 Firmware Upgrade 11 Troubleshooting 11.1 Power 11.2 Model 11.3 Wind source 11.4 Data output 11.4.1 Test output interfaces 11.4.2 Failure in an output interface...
  • Page 4: Product Overview

    1 Product overview: Congratulations, you are the owner of a brand new NMEA Connect Plus. The NMEA Connect Plus (NCP along the document) product line belongs to a family of gateways and range extenders. The NCP lets you connect any ultrasonic wind meter (wired or Portable) from Calypso´s portfolio to an NMEA 0183 or NMEA 2000 network, and/or extend your Bluetooth and WIFI signal range.
  • Page 5 High End: The most versatile model. You can receive wind data from any Ultrasonic wind meter within Calypso´s range of products (by the NMEA 0183 interface or by Bluetooth signal), and converts the wind data into NMEA 0183 sentences (wired and Wi‐Fi), NMEA 2000 PGNs and Bluetooth.
  • Page 6: Application Areas

    Display 3.2 ULTRASONIC PORTABLE to NMEA 2000 If you have a Calypso Ultrasonic Portable and want to monitor the wind data in your NMEA 2000 devices, the best option is to use the NCP: ´BT2000´ Model. The NCP will receive the wind data from your Ultrasonic via Bluetooth and export it into the NMEA 2000 interface.
  • Page 7 3.3 ULTRASONIC Wired or ULP485 to BLE and to NMEA 2000 If you have a Calypso Ultrasonic Wired or ULP485 and want to monitor the wind data in your NMEA 2000 navigation instruments and also in your BLE devices the NCP ‘W2000’...
  • Page 8 This model selects the first data stream that comes in (detects a wired data stream and connects otherwise detects BLE and connects) is the one that stays it to all output interfaces (NMEA 0183, NMEA 2000, BLE, or WIFI). The input data will be broadcasted across all output interfaces. Full NMEA 0183 Display...
  • Page 9: Package Content

    In order to use it you need a USB cable with end free wires. Take a look at section 6.1 for further information regarding the connection of the USB. 5.3 NMEA 2000® interface The NMEA Connect Plus is equipped with an NMEA 2000 interface to connect to an NMEA 2000 backbone.
  • Page 10 NCP will translate NMEA 0183 wind sentences into NMEA 2000 PGN's (messages). This feature enables a seamless integration between NMEA 0183 and NMEA 2000 navigation devices. Also wind data received via BLE is converted into NMEA 2000 protocol and transferred to an NMEA 2000 network. When connected to the NMEA 2000 backbone, the NCP receives its power from it, no additional power is needed.
  • Page 11 Low power – 126mA at 12 VDC (3 LEN) from NMEA 2000 bus. 5.4 NMEA 0183 The NMEA Connect Plus has two RS485 interfaces to be used as NMEA 0183 ports, whereby two wires are used to transmit the NMEA data.
  • Page 12: Wifi-Access Point

    NCP is able to transmit the following wind sentence: $IIMWV,XX,R,XX.XX,N,A*CR\r\n Wind speed in knots 5.5 WIFI NMEA 0183 server Models with Wi‐Fi have a NMEA 0183 Wi‐Fi server, that allows sending the input wind data via Wi‐Fi, using a TCP socket and sending it with the format of the NMEA 0183 sentences (see section 8.3 to configure the TCP port).
  • Page 13: Installation

    Before you start the installation make sure all power sources are off!! To connect a cable to the NCP internal interface follow the steps below: 1. Remove the screws to open the NMEA Connect Plus gateway. The connectors are in the position as the following image shows.
  • Page 14 (To achieve the IP68 rating, all glands must be occupied by round-section cables of between 4.5mm and 10mm or be replaced by blanking plugs) 5. Attach the NMEA Connect Plus securely to the vessel. 6. When all wires are connected and the gateway is closed, connect the cables to your network and power them if necessary (when using an NMEA2000 network the NCP will be powered through the NMEA 2000 cable.
  • Page 15 Ground Shield Not connected USB cable provided by Calypso Instruments has an additional black wire which is the Shield, and should be left unconnected. This wire is thicker and more matte colour than the previous one. 6.2 Connect NMEA 2000interface Identify the CAN connector.
  • Page 16 USB cable provided by Calypso Instruments has an additional black wire which is the Shield, and should be left unconnected. This wire has a more matte colour than the GND signal. 6.3 Connect NMEA 0183 interface Identify the RS‐485 and Power connector. You must connect your NMEA 0183 wires to the RS485 ports.
  • Page 17 Wired Standar Wired BLE/ ULP 485 External Power Wired WIFI Config RX+ Config Rx - 6.3.2 NMEA 0183 Output To connect a NMEA 0183 instrument to the NCP NMEA 0183 output, follow next table. NCP RS485 Output Connector NMEA OUT A/+ RS485 + NMEA OUT B/ - RS458 -...
  • Page 18 6.5 Shared power between NCP and RS485 device: If you want to use a single power supply to power the NCP and your Calypso ULTRASONIC, you have to share the GND from the power supply between the GND of POWER and the GND of the RS485 port.
  • Page 19 For example, the connection can be done in the following way: • ULTRASONIC wired BLE connected to the NCP: POWER +12V SUPPLY This image shows the connection of a Ultrasonic Wired BLE, using a power supply to power the ULTRASONIC and the NCP. The +12V (red wire) has to be connected to the +12V input of the NCP dedicated input power, and also to the Ultrasonic Vcc (yellow wire), you can put both cables together in the connector (as in the picture) or you can use a screw terminal block to...
  • Page 20 To access it, make sure you have connected your PC or device to your NMEA Connect Plus Access Point via Wi‐Fi (see section 5.7 -WIFI‐Access Point- for further details) or the NCP is connected via Wi‐Fi to your network (see section 5.8 and 8.1).
  • Page 21: Information Page

    From the main page, you can access the ‘Information page’, the ‘Status page’ or the ‘Configuration page’. Click the desired page to open it. 7.1 Information page The information page shows the following data: • NCP Model • • SSID •...
  • Page 22: Status Page

    7.2 Status page The Status page shows information about the current status of the device. This is useful for troubleshooting. Depending on the NCP Model, the web will show the functionalities that it has active.
  • Page 23: Configuration Page

    In BLE and N0183 sections, if Receiving is True, that shows that this is the Wind source it’s receiving data from. Only one wind source can be True. In BLE section, it also shows the MAC address of the ULTRASONIC connected and used as wind source, and the number of Centrals connected.
  • Page 24 8 Configuration: Access the Configuration page to modify the desired parameters. Important: after making any change along the configuration you must click the SAVE button and then RESET the device. 8.1 WIFI STATION CONFIGURATION, and IP CONFIGURATION This section is used to configure the NCP to connect to your Wi-Fi network. The NCP can be configured as Wi‐Fi Station to connect your network Access Point.
  • Page 25 After changing the configuration you must click the SAVE button and then reset the device Then the following page will appear: In the case no MAC is configured, the NMEA Connect Plus will connect the first ULTRASONIC BLE device detected.
  • Page 26: Technical Specifications

    Make sure that there are no two ports configured as inputs. After changing the configuration you must click the SAVE button and then reset the device. Then the following page will appear: 9 Technical specifications Certifications: Fully NMEA 2000 Certified RF certification FCC/CE‐RED/SRRC/TELEC Wi‐Fi certification...
  • Page 27 Supply Voltage (VCC Port) 9‐24V DC Supply Current (VCC Port) 150mA @12V DC Supply Current (USB Port) <200mA @5V DC Supply Voltage (NMEA 2000 Port) 9‐16V DC Supply Current (NMEA 2000 Port) 126mA @12V DC Load Equivalent Number (LEN) USB: Compatibility USB 1.1 and 2.0 Connectivity...
  • Page 28: Firmware Upgrade

    Max Output power 20 dBM Antenna Integrated internal antenna Range 100 m (open space) Security WPA/WPA2/WEP Mechanical: Size 93.3mm x 112.54mm x 35.30mm (LxWxH) Weight 100gr. Housing Material Policarbonate 94V‐2 Cable Diameter 3 holders (4‐8mm & 8‐12mm & 10‐14mm) Housing Cert TUV ,CE,ROHS Environmental Parameter...
  • Page 29 • If powered by USB, check the connections are right (section 6.1) and it’s properly powered. • If powered by the dedicated power, check the connections are right (section 6.4), and the power supply is connected and turned on. 11.2 Model Check your NCP Model is the one you need.
  • Page 30 the MAC address from which it receives. Check the MAC address is that of your device. If NCP doesn’t receive data from BLE interface. Check the Ultrasonic is powered on and sending data and make sure no other device is connected to the Ultrasonic prior to connect the NCP.
  • Page 31 • NMEA 0183: to check if the NCP is sending data through NMEA 0183 output interface, connect your computer (RS485 connection) to a RS485 output port of the NCP (you will need a RS485 to USB converter). In your computer use a ‘Serial/TCP Port terminal’ such as ‘Realterm’, ‘TeraTerm’, etc..
  • Page 32 6.2) and that the cable is properly connected to your NMEA 2000 backbone and this is powered. Check if the NCP is detected in your NMEA 2000 display or receiver, its ID is ‘NMEA CONNECT PLUS’. Go to ‘Status page’ and check the NMEA 2000 status, is should have...
  • Page 33 • NMEA 0183 Wi-Fi server failure: make sure your NCP and your PC/mobile are in the same Wi-Fi network and you are connecting the right IP and server port. If your PC/mobile is connected to the NCP Access point (section 5.7), the IP address of the NCP is 192.168.4.1.

This manual is also suitable for:

High endCmi1016Bt0183Bt2000W2000

Table of Contents