HUCK Seiltechnik GmbH • Dillerberg 3 • D-35614 Asslar-Berghausen seiltechnik@huck.net www.huck.net Please note the explanations and abbreviations and notes. For any queries please contact the manufacturer Contents Assembly Instructions Bird’s nest tree with bridge and slide Art.-No. 4652-2 ..1 Introduction Assembling ....................
HUCK Seiltechnik GmbH • Dillerberg 3 • D-35614 Asslar-Berghausen seiltechnik@huck.net www.huck.net Introduction Assembling General information This equipment should be installed, inspected, maintained and operated in accordance with EN1176-7 guidelines. Before installation work commences, please check that you have all of the equipment and fixation components in the parts list provided (see Tables 3-1 and 3-2).
HUCK Seiltechnik GmbH • Dillerberg 3 • D-35614 Asslar-Berghausen seiltechnik@huck.net www.huck.net Datasheet: Bird’s nest tree with bridge and slide Art.-Nr.4652-2 1. Component zone: 13200 mm x 7100 mm Impact area: 16900 mm x 11000 mm height of fall: 6000 mm Free height of fall: 2800 mm 2.
Page 6
HUCK Seiltechnik GmbH • Dillerberg 3 • D-35614 Asslar-Berghausen seiltechnik@huck.net www.huck.net Foundation edges must be rounded off (min.R = 100 mm)! Sizes of fundations are designed for soils class“4-5” (natural ground). Soil class 3: Non-cohesive to low-cohesive plasticity, sand, gravel and sand-gravel- mixtures, with very low portion of stones portion of stones (portion >...
HUCK Seiltechnik GmbH • Dillerberg 3 • D-35614 Asslar-Berghausen seiltechnik@huck.net www.huck.net Delivery contents (parts list with part numbers) 3.1. In words Table 3-1: Delivery contents, in words Element / Mis- Pos. Quantity Size O.K. Description sing Ø 193,7 mm / Steel post 6200 mm lg.
Page 8
HUCK Seiltechnik GmbH • Dillerberg 3 • D-35614 Asslar-Berghausen seiltechnik@huck.net www.huck.net Caps (black) Washers Stop nuts M8 x 75 mm Allen screws and Washers PVC pipe Ø400 x 850 mm (KNR) (Provided by customer) flagstone 400 x 400 mm PVC pipe Ø250 x 650 mm...
HUCK Seiltechnik GmbH • Dillerberg 3 • D-35614 Asslar-Berghausen seiltechnik@huck.net www.huck.net 3.2. In symbols Table 3-2: Delivery contents, in symbols Quanti- Pos. Symbol Ø 193,7 mm / 6200 mm lg. Ø 159 mm / 4100 mm lg. Play part (Nets, bridge and birds' nests) Ø...
Page 10
HUCK Seiltechnik GmbH • Dillerberg 3 • D-35614 Asslar-Berghausen seiltechnik@huck.net www.huck.net Ø 140 mm / 1650 mm lg. 1850 mm lg. (Pre-assembled on Pos.3) 1500 mm lg. / 50 x 50 x 5 mm AH 1750 mm / 3750 mm lg.
Page 11
HUCK Seiltechnik GmbH • Dillerberg 3 • D-35614 Asslar-Berghausen seiltechnik@huck.net www.huck.net 365 mm lg. (1x pre-assembled) Ø 139 mm 3,5 x 25 mm M10 x 175 mm 3 ml M12 x 25 mm Ø 193,7 mm \\CAD1\Standard\4652- 2\Montageanleitung\4652_2_Vogelnestbaum_Bruecke_und_GFK_Rutsche_mit_Leimbinder_SO_B_L_01_GBR.doc...
Page 12
HUCK Seiltechnik GmbH • Dillerberg 3 • D-35614 Asslar-Berghausen seiltechnik@huck.net www.huck.net M12 x 80 mm 500 x 500 mm M8 x 75 mm (KNR) Ø 400 mm / 850 mm lg. 400 x 400 mm (KNR) Ø 250 mm / 650 lg.
Page 13
HUCK Seiltechnik GmbH • Dillerberg 3 • D-35614 Asslar-Berghausen seiltechnik@huck.net www.huck.net Abbreviations Setting time min. 7-8 days hanging height Fix the pipe clamps at the appropriate positions. C25/30 concrete (for foundations) Q.ty required: 4,4 m Fill in around the central mast with concrete.
Page 14
HUCK Seiltechnik GmbH • Dillerberg 3 • D-35614 Asslar-Berghausen seiltechnik@huck.net www.huck.net The natural properties of wood can lead to different cross-sections in heat and humidity. e.g. Post Ø 180 mm (tolerance 173mm - 183mm) Possible lengths of the eye bolts or bearings...
HUCK Seiltechnik GmbH • Dillerberg 3 • D-35614 Asslar-Berghausen seiltechnik@huck.net www.huck.net Post installation checks If the equipment has not been installed safely, you must ensure that the public is prevented from using it. Marking filler depth Labelling the posts to show the depth of material provided as fall protection (i.e.
HUCK Seiltechnik GmbH • Dillerberg 3 • D-35614 Asslar-Berghausen seiltechnik@huck.net www.huck.net Introduction Maintenance General informations This equipment should be installed, inspected, maintained and operated in accordance with EN 1176-7 guidelines. Please note: Providing any necessary repairs are carried out, a piece of play equipment that is inspected regularly cannot become so damaged that it is dangerous.
HUCK Seiltechnik GmbH • Dillerberg 3 • D-35614 Asslar-Berghausen seiltechnik@huck.net www.huck.net General maintenance information Maintenance intervals Maintenance intervals are based on average use. Please note that more fre- quent inspections and/or maintenance are required if the play equipment is subject to intensive use.
Page 39
HUCK Seiltechnik GmbH • Dillerberg 3 • D-35614 Asslar-Berghausen seiltechnik@huck.net www.huck.net Faults Faults must be repaired as soon as they are detected. If serious defects that compromise safety cannot be repaired straight away, the public must be prevented from using the equipment with immediate effect.
HUCK Seiltechnik GmbH • Dillerberg 3 • D-35614 Asslar-Berghausen seiltechnik@huck.net www.huck.net Maintenance timetable Special advices 9.1.1 Maintenance interval We strongly advise you to carry out inspections and maintenance work within the specified periods as use of the equipment, the weather and malicious van- dalism cause wear and tear that compromises the safety and function of the equipment.
HUCK Seiltechnik GmbH • Dillerberg 3 • D-35614 Asslar-Berghausen seiltechnik@huck.net www.huck.net Regular maintenance Monthly maintenance 11.1 Check the spaces between the equipment and the ground (clearance and height of fall). 11.2 Check the ground surface in the area with fall protection for hard objects and loose foundations.
Zinc paint should be applied to corroded areas and scratches. The equipment must be inspected by someone with the necessary expertise in strict compliance with the instructions issued by Huck Seiltechnik GmbH. A copy of the inspection record should be given to the operator, who must confirm receipt.
HUCK Seiltechnik GmbH • Dillerberg 3 • D-35614 Asslar-Berghausen seiltechnik@huck.net www.huck.net Maintenance printout Name of item: Bird’s nest tree with bridge and slide / Art.-Nr. 4652-2 _________________________________________ Location: _______________________________________________________________________________________ Customer or operator: _____________________________________________________________________________ (Town, Town council, Kindergarten) Date of Inspector O.K.
After the installation of the equipment pass the installation and mainte- nance documents to the operator. The operator has to receive the hand over documents. The complete filled and signed hand over document should be sent to the supplier Huck Seiltechnik GmbH per Telefax +49 6443 8311-79 Art.-No.: 4652-2 Bird’s nest tree with bridge and slide...