Table of Contents Assembly instructions Midi Birds Nest Tree Art.-Nr. 4652-10 ....1 1.1 General information ..................3 Datasheet: Art.-Nr.4652-10 ................. 6 Scope of Delivery, inventory with serial numbers ........8 Erection instructions ................13 Post installation checks ................24 Maintenance Instructions Midi Birds Nest Tree Art.-Nr.
Page 4
Following installation, complete assembly instructions, maintenance instructions and a maintenance record must be sent to the operator who must confirm receipt in writing. See the last page of this document. All nuts and bolts are hot-dip galvanised or stainless steel. One of the characteristics of stainless steel is that uncontrolled cold welding may occur when the nuts are tightened.
Page 5
Drawings / Views All optical drawings are showing only the measurements/dimensions and are no mandatory technical views of the complete item. We reserve the right to change technical details of our articles which are serving for the further development of our articles and are reasonable for the customer.
2 Datasheet: Art.-Nr.4652-10 Space requirement: 4.0mØ and 7.50mØ including safety zone, height of fall 2:00 m Required safety surface: Ground surface Description Minimum Maximum material thickness of height of fall layer mm 1000* Lawn top soil 2000 Grain size 20 – 80 Chipped bark ...
Page 7
Round off foundation edges (min.R = 100 mm)! Sizes of fundations are “4-5” (natural ground). Soil class 4: soft to medium plasticity, interleave bound, with minor portion of stone (portion < 30% with bigger diameter of 63 mm grain size). Soil class 5 : ground with soil class 3 and 4 with big portion of stones (portion >...
3 Scope of Delivery, inventory with serial numbers 3.1 In words (please notice: piece numbers refer to 1 equipment) Table 3-1: Scope of delivery, inventory with serial numbers, in words Pos. Quantity Element / Size O.K. Missing Description Steel post Ø...
3.2 With symbols Table 3-2: Scope of delivery, inventory with serial numbers, with symbols Pos. Quantity Symbol Ø 193.7 mm, 5,30 m lg. 1500 x 800 x 800 Ø 140 mm, 1,65 m lg. - 9 -...
Page 10
Pos. Quantity Symbol M12 x 110 mm Ringmutter M12...
Page 11
Pos. Quantity Symbol für Ø 140 mm M10 x 175 mm Loctite 3 ml M12 x 25 mm Anchor plate 6mm shackle - 11 -...
Page 12
Pos. Quantity Symbol Plastic pipe (Provided by customer)
Page 23
Shortcuts and Abbreviations for Diagrams: Setting time min. 7–8 days Baton positioned on site to secure the anchor chain Anchor the nets to the ground with type-6 shackles C25/30 concrete (for foundations) Q.ty required ~2.8 m³ D.be. Fill in around the central mast with concrete. (between drainage tube and central mast) D.N.w.a.G.
5 Post installation checks If the equipment has not been installed safely, you must ensure that the public is prevented from using it. Marking filler depth Labelling the posts to show the depth of material provided as fall protection (i.e. loose filler). The equipment has not been installed safely in the following cases: Safe equipment installation is not complete.
Introduction Maintenance General informations This equipment should be installed, inspected, maintained and operated in accordance with EN 1176-7 guidelines. Please note: Providing any necessary repairs are carried out, a piece of play equipment that is inspected regularly cannot become so damaged that it is dangerous.
General maintenance information Maintenance intervals Maintenance intervals are based on average use. Please note that more frequent inspections and/or maintenance are required if the play equipment is subject to intensive use. Inspection frequency The frequency of inspections must be based on actual use. Factors that affect frequency include vandalism, location (e.g.
7.10 Faults Faults must be repaired as soon as they are detected. If serious defects that compromise safety cannot be repaired straight away, the public must be prevented from using the equipment with immediate effect. 7.11 Loose screws Loose screws always cause quality problems and put safety at risk. Therefore, loose screws should always be tightened and checks carried out to ensure that there are no missing screws (e.g.
Maintenance timetable Special advices 9.1.1 Maintenance interval We strongly advise you to carry out inspections and maintenance work within the specified periods as use of the equipment, the weather and malicious vandalism cause wear and tear that compromises the safety and function of the equipment.
10 Monthly maintenance Check the spaces between the equipment and the ground (clearance and height of fall). Check the ground surface in the area with fall protection for hard objects and loose foundations. Check all connecting elements and fittings for wear and tear and tighten if necessary.
The equipment must be inspected by someone with the necessary expertise in strict compliance with the instructions issued by Huck Seiltechnik GmbH & Co. KG. A copy of the inspection record should be given to the operator,...
14 Maintenance printout Name: Midi Birds Nest Tree / Art.-Nr. 4652-10 ________ Location: _______________________________________________________________________________________ Customer or operator: _____________________________________________________________________________ (Town, Town council, Kindergarten) Date of Inspector O.K. Accessib Barriered Defects Repaire Date inspection d by Please copy and return once a year after main inspection has been carried out to the manufacturer by Telefax +49(0)6443/...
The complete filled and signed hand over document should be sent to the supplier. Art.-Nr.: 4652-10 Gerätetyp: Midi Birds Nest Tree - Midi Seriel number: ________________________________________ Customer or operator (Town, Town council, Kindergarten, etc.): _____________________________________________________ _____________________________________________________ Competent person in charge:...
Need help?
Do you have a question about the Midi Birds Nest Tree and is the answer not in the manual?