Closing Seam Machine 1282-4 Working Instructions
D.3
21 NR# OF CONDENS. STITCHES
Length of section during which the stitch is condensed

Meaning of functions on access level 2

The function keys on access level 2 are assigned to the symbols that
are shown on the display. These symbols are only visible when access
level 2 has been selected.
)

F1 Request global parameter list
F2 Enable or disable the seams of a sewing program
F3 Enable preseams
F4 No function
F5 Reduce machine sewing speed
F4 No function
F7 Reset day counter to zero
F8 Display inputs/outputs

Requesting the global parameter list

Global parameters are values that control the basic functions of the ma-
chine. Changing global parameters will result in changes of all stored
sewing programs.
NOTE - Changing global parameters
At the factory, the setting and interadjustment of the basic
machine parameters have been optimized. Improper modi-
fications to the values may impair the processing quality
or even damage machine components.
1. Requesting the GLOBAL PARAMETER list:
• Press the  key
2. Move up and down in the parameter list:
• Press theG or J key
3. Activate the input field of the parameter:
• Press the I key
Programming
Q\[P+-
!
Beisler Automated Sewing Equipment
- 17 -