Installer Programmable Features - Excalibur AL-185X-EDPB Operation Manual

Deluxe 2-way alarm
Table of Contents

Advertisement

Feature #17 - Remote Start activation
Press "start" button 2 times
Press "start" button 1 time
Press lock & unlock
This feature changes how the remote start feature is activated using the controller or
transmitter. It also affects how many pulses activate remote start from the WHITE/
BLUE activation input wire
Feature #18 - Remote Start Run Time
10 minutes
(press "disarm/unlock" button to program) - DeFaulT
5 minutes
(press "arm/lock" button to program)
15 minutes
(press "trunk" button to program)
20 minutes
(press "start" to program)
This feature sets the period of time that the engine will run when remote started. If the
engine is not stopped by controller/transmitter command or a safety circuit violation,
the engine will automatically stop upon the expiration of the selected time period.
This group of Installer Programmable Features are all accessed as a group in the second level of
features' programming. These features have a direct affect upon the system's operations related
to the installation and vehicle type anD ShOulD Only be ChangeD by The inSTalleR!!!
Feature #1 - Doorlocking Functions
0.8 Second Outputs
3 Second Outputs
Double Pulse unlock Output (press "trunk" button to program)
Total Closure lock Output
This single feature gives the installer several needed options, to match the system's doorlocking
outputs to suite different vehicle requirements. The total closure setting provides a 28 second lock
pulse and a 08 second unlock pulse
Feature #2 - light Relay Functions
Dome light Output
(press "lock" button to program) - DeFaulT
Door lock
(press "unlock" button to program)
ignition Output
(press "trunk" button to program)
accessory Output
(press "start" button to program)
The system has two built-in relays, which can be programmed to perform several different func-
tions. The primary function of this relay, is to operate the vehicle's dome, or interior lighting as
part of the system's operations. Optionally, if desired or needed, this relay can be programmed to
be a door lock relay, or as medium-capacity ignition or accessory outputs (10A max), if needed for
remote starting use
user Programmable Features (cont'd)
(press "lock" button to program) - DeFaulT
(press "unlock" button to program)
(press "trunk" button to program)

installer Programmable Features

(press "lock" button to program) - DeFaulT
(press "unlock" button to program)
(press "start" button to program)
19