DENTAL UNIT Rod Type OPERATING INSTRUCTIONS IMPORTANT This manual provides operating instruction for CLESTA II ROD TYPE. The instructions contained in this booklet should be thoroughly read and understood before operating the unit. After the installation is completed, file this manual and refer back to it for future maintenance.
TABLE OF CONTENTS Page SAFETY PRECAUTIONS -------------------------------------------------------- 1 1. OVERVIEW AND MAJOR PARTS ------------------------------------------- 6 2. DIMENSIONS & SPECIFICATIONS 2-1. DIMENSIONS --------------------------------------------------------------- 7 2-2. SPECIFICATIONS ---------------------------------------------------------- 7 3. OPERATING INSTRUCTIONS 3-1. DOCTOR TABLE SECTION --------------------------------------------- 8 3-2. CUSPIDOR UNIT SECTION --------------------------------------------- 15 3-3.
Page 5
In addition, it is the device which combines with dental chair and dental light. Handpieces that can be used with this product Use the Handpieces described on page 30. Chair that can be used with this product Use the Chair described on page 30. Dental Light that can be used with this product Use the Dental Light described on page 30.
Page 6
SYMBOLS In this manual, on the labels or on the control panel of CLESTAⅡROD TYPE, following symbols are used. Confirm the meaning of each symbol. Reference number Refer to operating instructions Serial number *1 : The color of black part is blue in the actual label.
Page 7
REQUEST FOR WATER FLUSHOUT (DISCHARGE) E type:Standard E Precautions for water quality safety A type:Option A C A U T I O N To maintain the water quality for treatment and for stable water supply to the handpieces, ensure to carry out flushout of the residual water in the unit before starting treatment.
SAFETY PRECAUTIONS Before use, read the “Safety precautions” carefully to ensure proper use. ■ The following information is designed to ensure safe use of this product and to prevent injury and damage ■ to you and others. The precautions contained here are classified depending on the severity and degree of imminence of possible injury or damage resulting from improper use.
Page 9
SAFETY PRECAUTIONS WARNING 9. Ensure the maintenance of this product • Failure to maintain this product may lead to physical injury or property damage. • Refer to the section of maintenance. 10. Do not place objects weighing 1.5 kg or more on the Sub tray Do not place objects weighing 1.5 kilograms or more on the Sub tray.
Page 10
SAFETY PRECAUTIONS CAUTION 4. Discontinue use if you feel that “something is wrong” Always be careful to inspect this product for looseness, rattling, tilting, wobbling, sounds, temperature, odors, etc. Immediately discontinue use at the first feeling that “something is wrong.” 5.
Page 11
SAFETY PRECAUTIONS CAUTION 18. Precautions for cleaning the operation panel (membrane switches) Penetration of droplets of sanitizing spray into the back of the operation panel may be associated with switch failure. Use a paper towel soaked with sanitizing solution to clean the surface of the operation panel. 19.
Page 12
SAFETY PRECAUTIONS NOTICE 1. Troubleshooting and contact information In the case of any problems, discontinue use, turn off the main switch and contact the dealer or our company. 2. Check operation of the compressor With no air supplied, this product does not operate even after turning on the main switch. Turn on the power of the compressor before operating this product.
1. OVERVIEW AND MAJOR PARTS Fig.1-1 Overview and Major Parts Cupfiller Nozzle Saliva Ejector Handpiece Handle Cupfiller Base Assistant Holder Arm Right Hand Side : Standard Bowl Flush Nozzle Cuspidor Top Left Hand Side : Option Spittoon Bowl Cuspidor Body Solid Collector Light Pole Dental Size Film Viewer...
Fig.3-1 Master Switch and Indicator seveal seconds on the indicator. Wait operation until Fig.3-2 is changed to Fig.3-3 Indicator on the indicator. CLESTA I I Ver.00 CLESTA I I Belmont Fig.3-2 Fig.3-3 (2) Main Control Panel A Type E Type A...
Page 16
Bowl Flush Switch (Fig.3-6) A E Momentarily press the bowl flush switch, water flushes for about 5 seconds and stops automatically. (Timer mode) Keep pressing the bowl flush over 2 sec.,water flushes continuously until the bowl flush switch is pressed again. (Continuous mode) Fig.3-6 Bowl Flush Switch While the bowl flush is working by momentarily pressing the bowl flush switch the bowl flush will stop.
Page 17
Coolant Water ON/OFF Switch (Fig.3-11) A E When a handpiece is picked up and this switch is pressed, both LED A (air) and LED W (water) lights up, the coolant water and air comes out from the (Amber) (Green) handpiece. In case of air motor or air turbine, switching between spray (both of LED A and LED W are lit) and OFF occurs when this switch is pressed.
Page 18
Function Switch (Fig.3-15) A E Use this switch for setting various working conditions. As for the setup procedures, please refer to 3-1.(3) a-i. Fig.3-15 Function Switch (3) Function Swicth Setup Procedure A E a. Timer Timer can be set maximum 90 mins. 50 secs. in 10 secs. segment. Decrease Switch Function Switch Increase Switch...
Page 19
c. Flush out system The CLESTA II is equipped with two types of flush out system. Short time flush out is for cleaning handpiece water lines. Long time flush out is for handpiece water lines, bowl flush water line and cupfiller water line. 1) Short time flush out Momentarily press the function switch three times and momentarily press the decrease switch.
Page 20
f. Electronic sound for timer Electronic sound for timer can be changed. Function Switch Chair Auto Mode Switch Momentarily press the function switch six times. Momentarily press one of chair auto mode switch (0,1,2,LP ) then the new electronic sound is to be memorized. g.
Page 21
(4) Doctor Table Chassis (Fig.3-16) A.The handpiece spray water control knobs are located under the doctor table. Handpiece Rest Each handpiece spray water control knob is marked 1-4 from (HP4) the left side HP1,HP2,HP3,... The handpiece spray water volume can be controlled independently.
3-2. CUSPIDOR UNIT SECTION Dental Light switch (for E Type) Cupfiller Switch Bowl Flush Switch Chair Auto Mode Switches Assistant Side Control Panel Dental Light Mode Selection Switch Water Heater EURUS LIGHT/ Switch 900 Dental Light (Type 920) Service Water Control Knob Service Air Service Water...
Page 23
C. Bowl Flush Flow Control Knob (Fig.3-20) Bowl flush flow volume can be controlled by the bowl flush flow control knob. (Pinch valve system) Loosen the lock nut and adjust bowl flush water flow volume by turning the knob. Tighten the lock nut after adjustment. Note : Turning a knob counterclockwise increase flow volume and turning clockwise will decrease.
Page 24
(Fig.3-24, Fig.3-25) (7) Clean Water System (Optional) (Fig.3-24) (Fig.3-24) Remove or attach the bottle (Fig.3-25) Turn off the pressurization ON-OFF switch. Water bottle may be remove by turned in direction A. Fig.3-24 Clean Water System It is attached when turned in direction B. •...
10˚ 3-3. FOOT CONTROL SECTION (1) Foot Control (Type A2) (Fig.3-29 & 3-30) A A. Drive Air Pedal Pick up a handpiece from the handpiece rest (pull the rod about 10 degrees to forward) and depress the drive air pedal, the handpiece starts running.
5. CARE AND MAINTENANCE Cleaning Unit Cleaning and Sterilization of product exterior Clean the metallic parts with a dry soft cloth. Wipe off water immediately if water is put on the product. Water may cause rusting. Clean the resin parts with a wet soft cloth. Use FD333 or FD366 made by Durr or ethanol for cleaning and bacteria elimination from the product exterior.
Page 27
(2) Solid Collector (Fig.5-4) Solid Collector Filter Pull out the solid collector filter and clean it. After cleaning, refit the solid collector firmly. (3) Tubings and hoses Tubings and hoses can be cleaned with FD333 or FD366 made by Durr. (4) Cleaning vacuum and saliva ejector lines (Fig.5-5) Fig.5-4 Solid Collector Filter The sucking unit comes into contact with secretions, spit and...
Page 28
(6) Vacuum Handpiece and saliva ejector Handpiece * Cleaning amd sterilization must be done every after use to patients. VH-18 BT06 Vacuum Handpiece Saliva ejector Handpiece For effective sterilization, washing for removing contamination and immersion by a cleaning agent are required. Then, rinse by water in order to remove residual procedures from cleaning to sterilization.
Page 29
Assembly before sterilization (Fig.5-11) Caution when assembling vacuum handpiece before Vacuum Tip/Vacuum Handpiece/Saliva Ejector Handpiece sterilization can be autoclave. Vacuum handpiece and saliva ejector handpiece have to assemble before autoclave. Insert the cap Body straight down When assembling the vacuum handpiece, align the two Align the surfaces;...
Page 30
(7) Belmont 77 Syringe * Cleaning amd sterilization must be done every after use to patients. Disassembly (Fig.5-13) Remove the nozzle from syringe by turning it in direction A. Cleaning by hand A. Wipe off the surface contamination by a cloth while rinsing the surface by running clean warm water at 40±5 degrees.
Page 31
(8) Handpieces Observe the instructions given in the package insert and Instruction Manual included with the handpiece to clean it. (9) Air Filter Drain Valve (Fig.5-16) 【 CLESTAⅡ CHAIR 】 Air filter drain valve is located under the Air Filter Maintenance Lid Drain Valve maintenance lid.
6. MAINTANANCE AND INSPECTION 6-1. Guide for daily maintenance and inspection (Maintenance and inspection by user) •Management of maintenance and inspection of medical equipment should be implemented by the user (medical institution). • For safe use of this product, it is necessary that inspection should be conducted in the specified frequency on the tems described below.
Page 33
Inspection method Influence if inspection Maintenance required in case Item Frequency not conducted of nonconformity and diagnosis Care Faulty suction may Clean the suction line and filter in After Flush the suction line, and Vacuum arise. accordance with "Method for closing then clean the filter of the and saliva...
6-2. Guide for Periodical Check-up Some parts and components of the products are degraded or deteriorated depending on the frequency of use. Annual check-up and maintenance, as well as replacement of consumable parts, are required. The required parts (including consumable parts) are listed below. It may be different from the following list depending on the option of the unit.
8. ELECTROMAGNETIC COMPATIBILITY(EMC) This product complies with EMC Standard EN60601-1-2:2015. 1. Precautions regarding EMC and compliance with accompanying documents Medical electrical equipment requires special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided in this booklet. 2.
Page 36
6. Electromagnetic immunity declaration 2 Guidance and manufacturer’s declaration – electromagnetic immunity The CLESTAⅡ Unit is intended for use in the electromagnetic environment specified below. The customer or user of the CLESTAⅡ Unit should ensure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level...
However, there still could be a case that the connectors of turbines or air motors may not fit into some handpieces due to the manufacturing tolerances. Have your local authorized Belmont dealer check the connectability before purchasing the handpiece. Except for our recommended handpieces, we shall not be liable for any problems deriving from bad connectability or their performance.
12. ACCESSORIES It may be different from the following list depending on the specification of the unit. Accessories intended use, etc. The container to take in cotton and swab for dental treatment. Receptacle to do away with used cotton,etc. Grip for portability of foot control to reduce hand contact.
Page 39
Declaration of Conformity We hereby declare that the product listed below complies with the essential requirements of the Medical Device Directive: 93/42/EEC and RoHS Directive: 2011/65/EU based on category 8 of Annex I. Product : DENTAL UNIT (CLASS IIa) Model : CLESTAⅡ "...
Page 40
NOTE TAKARA COMPANY EUROPE GmbH Berner Strasse 18, 60437 TAKARA BELMONT CORPORATION Frankfurt am Main, Germany 2-1-1,Higashishinsaibashi ,Chuo-ku,Osaka, 542-0083 Japan Tel:+49 69 506878 0 TEL. : +81 6 6213-5945 FAX : +81 6 6212 3680 Fax:+49 69 506878 20 BOOK NO. FEFA27Y0...