Installation

Update ADM Software

1. Shut down system. See your Reactor operation
manual for shutdown instructions.
2. Open the top and bottom door latches to the electri-
cal cabinet.
3. Open the electrical cabinet. Using a Phillips screw-
driver, loosen the four ADM mounting screws in the
inside of the cabinet door.
4. Lift up the ADM and pull it away from the Reactor to
unseat the mounting screws. For easy reassembly,
leave the loosened screws attached to the ADM.
5. Remove the token access panel on the back of the
ADM.
6. Insert and press the software upgrade token firmly
into the slot.
NOTE: There is no preferred orientation of the token.
7. Turn on the system power.
A status is shown while software is updating to
indicate progress. To prevent corrupting the software
load, do not remove the token until the status screen
disappears.
10
NOTICE
NOTE: When the ADM display turns on, you may see
the following screens:
First:
Software is checking which
modules will take the
available updates.
Second:
Status of the update with
approximate time until
completion.
Third:
Updates are complete.
Icon indicates update
success/failure. See the
following table.
Icon
Description
Update successful.
Update unsuccessful.
Update complete, no changes necessary.
Modules were updated or didn't require
an update; however, one or more mod-
ules need to be updated manually with a
token.
8. Remove the software update token.
9. Replace the token access panel.
10. Remount the ADM using the four ADM mounting
screws. Tighten the screws fully.
11. Close and lock and the cabinet door with the door
latches.
12. Press
to continue to the operation screen.