Description
XVP S
Wall-mounted video intercom entry panel with touch
screen for IP360 system.
XVP F
Recessed video intercom entry panel with touch
screen for IP360 system.
Function of terminals
B
Local power supply input12 – 24 V DC
1
CAN BUS data line
2
Electric lock 12 V - 1 mA 12 V - 1 A max.
3
Earth
4
Door release button (NO)
5
Open door contact input (NC)*
6
Entry panel enabling output
7
*Active to earth
Max relay contact 1 A 30 V (AUX 2)
8
The contact can be programmed to perform
different functions.
Button for programming.
9
Press the PROG button to access the SETTINGS
section.
RESET button
9
When pressed it restarts the device.
This operation DOES NOT delete any programming
Technical data
MODELS
XVP F
Dimensions for recess
153 x
mounting (mm)
406 x 15
Dimensions for wall
mounting (mm)
Packaging dimensions
225 x 520 x 145
(mm)
Packaging weight (kg)
Power supply (V)
IEEE 802,3at POE+
PoE power supply
Consumption in stand-by
mode (mA)
Operating temperature (°C)
Protection rating (IP)
Protection rating (IK)
Video standard
Display
Display resolution (pixels)
Standard wireless
Bluetooth LE 5.0
Radio frequency (MHz)
Transmission power (dBm)
Proximity sensor range
(cm)
The minimum on temperature from cold is
-25°C.
Recess-mounted installation
The wall must be perfectly flat and flush with
the box to reach the IP rating 55.
Wall in the box at the desired height
A
taking into account the TOP indication and the
positioning of the camera lens.
Eliminate one or more break points of the box.
Thread the pipe with the system conductors
C
1
through one of the break points.
Wall in the box.
For a better grip, push the fixing tabs
C
2
outwards.
Lower the bracket.
C
3
Hook the entry panel onto the support.
D
1
Remove the terminal cover.
D
2
Make the connections.
E
MTMRFID module installation (not provided)
Remove the module fastening bracket.
F
1
Make the connections to the entry panel
F
2
using the FLAT cable.
Position the module using the four pegs as a
F
3
centring unit.
Lock the RFID module fixing the bracket.
G
2
Fasten the bracket in one of the two positions,
depending on the thickness of the device.
If a third-party RFID device is installed,
H
replace the tag.
Fasten the front to the box using the screws
I
1
provided.
Position the cover strips.
I
2
To remove the cover strips, use the key provided.
J
Wall-mounted installation
The wall must be perfectly flat and flush with
the bottom of the box to reach the IP rating 55.
To remove the front part of the entry panel
K
from the box, use the key supplied.
Secure the box at the desired height
XVP S
A
taking into account the TOP indication and the
-
positioning of the camera lens.
Eliminate one or more break points of the box.
153 x
-
Thread the pipe with the system conductors
L
1
406 x 50
through one of the break points.
Secure the box to the wall using the plugs
L
2
and screws supplied.
3,3
Lower the bracket.
L
3
12 – 24 DC
Hook the entry panel onto the support.
M
1
Remove the terminal cover.
M
2
(25.5W)
Make the connections.
N
700
MTMRFID module installation (not provided)
Remove the module fastening bracket.
-40 ÷ +55
O
1
Make the connections to the entry panel
O
2
55
using the FLAT cable.
08
Position the module using the four pegs as a
O
3
H.264
centring unit.
TFT 7"
Lock the RFID module fixing the bracket.
P
2
1024 x 600
Fasten the bracket in one of the two positions,
depending on the thickness of the device.
2400
If a third-party RFID device is installed,
Q
0
replace the tag.
30 ÷ 130
Fasten the front to the box using the screws
R
1
provided.
Position the cover strips.
R
2
Remove the protective films on the glass.
To remove the cover strips, use the key provided.
S
This device complies with Part 15 of the FCC
Rules. Operation is subject to the following
two conditions:
1 - This device may not cause harmful
interference.
2 - This device must accept any interference
received, including interference that may
cause undesired operation.
This product contains FCCID: QOQBGM13P.
FRANÇAIS
Instructions générales pour
l'installateur
Lire attentivement les instructions avant de
commencer l'installation et d'effectuer les
interventions comme indiqué par le fabricant. •
L'installation, la programmation, la mise en service
et l'entretien doivent être effectués par du personnel
qualifié et dans le plein respect des normes en
vigueur. • Avant toute opération de nettoyage,
d'entretien ou de remplacement de pièces
détachées, mettre le dispositif hors tension. • Ce
produit ne devra être destiné qu'à l'utilisation pour
laquelle il a été expressément conçu et toute autre
utilisation est à considérer comme dangereuse.
• Le fabricant décline toute responsabilité en
cas d'éventuels dommages provoqués par des
utilisations impropres, incorrectes et déraisonnables.
• Ce produit est conforme aux directives de
référence en vigueur.
Mise au rebut et élimination
Ne pas jeter l'emballage et le dispositif dans la
nature au terme du cycle de vie de ce dernier, mais
les éliminer selon les normes en vigueur dans le
pays où le produit est utilisé. Le symbole et le sigle
du matériau figurent sur les composants recyclables.
LE CONTENU DE CE MANUEL EST SUSCEPTIBLE DE
SUBIR DES MODIFICATIONS À TOUT MOMENT ET
SANS AUCUN PRÉAVIS.
LES DIMENSIONS SONT EXPRIMÉES EN
MILLIMÈTRES, SAUF INDICATION CONTRAIRE.
Description
XVP S
Portier vidéo externe avec écran tactile pour système
IP360, mural.
XVP F
Portier vidéo externe avec écran tactile pour système
IP360, encastrable.
Fonction des bornes
B
Entrée alimentation locale12-24 VDC
1
Ligne données CAN BUS
2
Serrure de verrouillage électrique 12 V - 1 mA
3
12 V - 1 A max.
Masse
4
Bouton ouvre-porte (NO)
5
Entrée contact pour ouverte (NF)*
6
Sortie activation poste externe
7
*Activée vers la masse
Contact relais max. 1 A 30 V (AUX 2)
8