4-4-20 SPI Feedback Error
Outdoor unit display
◑(Operation)
Indoor unit display
Criteria
• Check if the output of SPI Feedback is 12V.
Cause of problem
• SPI defect
1. How to check
Is the SPI connector of an
indoor unit separated from PCB?
Can you measure 12V from
#1, #4 power with SPI connector
Samsung Electronics
◑(Timer)
×(Fan)
Yes
예
being connected?
Yes
Replace Main PCB
◑(Filter)
×(Defrost)
No
Connect the connector to PCB
and reoperate
#1
#4
No
Replace SPI
Troubleshooting
4-63