Spi Feedback Error - Samsung AM007FN1DCH/AA Service Manual

System airconditioner
Hide thumbs Also See for AM007FN1DCH/AA:
Table of Contents

Advertisement

Troubleshooting

4-4-20 SPI Feedback Error

Outdoor unit display
Indoor unit display
Criteria
Cause of problem
1. How to check
indoor unit separated from PCB?
Can you measure 12V from
#1, #4 power with SPI connector
4-54
◑(Operation)
◑(Timer)
• Check if the output of SPI Feedback is 12V
• SPI defect
Is the SPI connector of an
Yes
being connected?
Yes
Replace Main PCB
×(Fan)
◑(Filter)
×(Defrost)
No
#1
#4
No
Connect the connector to PCB
and reoperate
Replace SPI
Samsung Electronics

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Am012fn1dch/aaAm009fn1dch/aaAm018fnndch/aaAm009fnndch/aaAm020fnndch/aaAm012fn4dch/aa ... Show all