● Setting
- Select the Input / Output
Set the following value to "LineModeAll" register. Setting value is Integer type.
Each bit corresponds to each Line (bit0=Line0, bit1=Line1).
Line2 is available. Line0 is dedicated input. Line1 is dedicated output.
- Select the Line of the I/O connector
Set the following value to "LineSelector" register. Select the line to output "LineSource" signal.
Setting value is Enumeration type.
- Select the source of GPIO output signal
Set the following value to "LineSource" register to change GPIO output signal selected by "LineSelector".
Setting value is Enumeration type.
LineSource
Off (*)
FrameTriggerWait
FrameActive
FrameTransfer
ExposureActive
UserOutput
Timer0Active
- Set the UserOutput signal
Set the following value to "UserOutputValueAll" register. Setting value is Integer type.
Each bit corresponds to each Line (bit0=Line0, bit1=Line1).
Copyright © 2016 TOSHIBA TELI CORPORATION, All rights reserved.
LineModeAll
0 (*)
1
LineSelector
Line1 (*)
Line2
No output.
Indicating waiting a Random Trigger Shutter.
An External trigger is input during this period, exposure starts immediately.
Period from exposure start to CMOS transfer completion.
Period of transferring image data on USB bus.
Period from exposure start to exposure end.
Outputs the value set in "UserOutputValueAll".
This signal can be used as strobe control signal.
The delay time and pulse width of this signal are configurable.
I/O connector pin assignment
Input
Output
* initial factory setting
I/O connector pin assignment
2 pin: GPIO Output
1 pin: GPIO Input / Output
* initial factory setting
Signal description
58 / 92