Toshiba BU505MCG Instruction Manual page 56

Cmos camera
Table of Contents

Advertisement

- Set the number of frames to exposure (In Bulk mode)
Set the number of frames to exposure to "TriggerAddtionalParameter". Setting value is Integer type.
- Set trigger delay (HardwareTrigger operation only)
Set the following value to "TriggerDelay" register. Setting value is Float type.
Adds delay time from trigger edge to exposure start.
- Grabs image stream by software trigger
When executes "TriggerSoftware" register command, software trigger command is generated. Camera
starts exposure by receiving software trigger command.
● Note
In SoftwareTrigger operation, the delay time from "TriggerSoftware" to exposure is not guaranteed.
Copyright © 2016 TOSHIBA TELI CORPORATION, All rights reserved.
TriggerAdditionalParameter
Minimum (*)
Maximum
TriggerDelay
Minimum (*)
Maximum
55 / 92
Value
0 [frame]
255 [frames]
* initial factory setting
Value
0.00[μs]
2000000.00[μs]
* initial factory setting