Connection - Toshiba BU505MCG Instruction Manual

Cmos camera
Table of Contents

Advertisement

Connection

Camera
(Mirco B)
(e-CON)
Camera mounting unit
CPTBU
Notes on Connection:
- Please confirm the power supply of the camera off when plugging in or pulling out the I/O Connector. It causes the
breakdown.
- If your camera is used in a system where its connectors are subjected to strong repetitive shocks, its connectors are
possible to break down. If you use your camera in such a situation, use an USB3.0 cable with a lock screw, and secure
the camera cable as close as possible to the camera body for avoid physical shock to the camera connector.
- About e-CON cable: In the case that electric-wire is long or thin, input and output voltage may not satisfy specifications
of the camera or your system by voltage drop. Please confirm wires' specifications before use them.
-
Lost packets may occur by an electrical characteristic of the transmission line of USB3.0. (USB3.0 Interface Card,
USB3.0 Cable, and USB3.0 HUB).
Copyright © 2016 TOSHIBA TELI CORPORATION, All rights reserved.
USB3.0 Cable
← Control Packet
Stream Packet →
e-CON Cable
1. Line2
2. Line1
3. GND
4. Line0
(Standard A)
Interface Card
15 / 92
Host(PC etc.)
D4253386C
http://www.toshiba-teli.co.jp/en/