1 Introduction
1.1 Product Features
The camera is applicable for both indoor and outdoor
conditions, and the application scenarios include road,
warehouse, underground parking lot, bar, etc..
The main features are as follows:
High performance CMOS sensor
Low illumination, 0.005 Lux @ (F2.0, AGC ON), 0 Lux
with IR
IR cut filter with auto switch
OSD menu with configurable parameters
Auto white balance
internal synchronization
SMART IR mode
PoC (with -E)
3-axis adjustment
1.2 Overview

2 Installation

Before you start:
Make sure the device in the package is in good
condition and all the assembly parts are included.
The standard power supply is 12 VDC or PoE (802.3
af), please make sure your power supply matches the
camera's.
Make sure all the attached equipment is powered off
during installation.
Make sure that the wall is strong enough to
withstand four times the weight of the camera and
the bracket (if applicable).
If the wall is cement, insert plastic anchors before
installing the camera. If the wall is wooden, use
self-tapping screws to secure the camera.
If the product does not function properly, contact
your dealer or the nearest service center. Do NOT
disassemble the camera for repair or maintenance.
2.1 Ceiling/Wall Mounting without Junction Box
Steps:
Stick the drill template (supplied) to the place
1.
where you want to install the camera.
2.
Drill the screw holes and the cable hole (optional)
in the ceiling/wall according to the drill template.
Bracket
Main Body
Lens
Photoresistor
Overview
Figure 1-1
Video Cable
Power Cord