Caution
connector, you must attach the cable shield to the chassis grounding terminal using
2
1.3 mm
(16 AWG) or larger wire. Attach a ring lug to the wire and attach the wire
to the chassis grounding terminal. Solder the other end of the wire to the cable
shield. Use shorter wire for better EMC performance.
For more information about ground connections, visit
.
emcground
Connecting the cRIO-9034 to Power
The cRIO-9034 requires a 9 V to 30 V external power supply. The cRIO-9034 filters and
regulates the supplied power and provides power for the C Series modules. The cRIO-9034
has a primary power input, V1, and a secondary power input, V2.
The POWER LED on the cRIO-9034 indicates which power input is in use, as shown in the
following table.
LED Color
LED Pattern
Green
Yellow
Caution
connecting cable longer than 3 m (10 ft). A DC mains supply is a local DC
electricity supply network in the infrastructure of a site or building.
What to Use
Ferrite
Screwdriver, 2.54 mm (0.10 in.) flathead
Primary power supply, 9 V to 30 V, 40 W minimum
(Optional) Secondary power supply, 9 V to 30 V, 40 W minimum
NI recommends the power supplies listed in the following table for the cRIO-9034.
8 | ni.com | NI cRIO-9034 Getting Started Guide
If you use shielded cabling to connect to a C Series module with a plastic
Table 2. POWER LED Indicators
Solid
The cRIO-9034 is powered from the V1 input.
Solid
The cRIO-9034 is powered from the V2 input.
Off
The cRIO-9034 is powered off.
Do not connect V2 to a DC mains supply or to any supply that requires a
ni.com/info
and enter the Info Code
Indication