Preparing To Install The Lift; Controller Harness Connections - Harmar Mobility Highlander CPL400 Installation And Owner's Manual

Commercial platform lift
Hide thumbs Also See for Highlander CPL400:
Table of Contents

Advertisement

5

Preparing to Install the Lift

Final Site Inspection
Verify the surface the lift will mount to is smooth and level. This surface must be made from 3,500 psi
reinforced concrete with a minimum thickness of 4".
Verify that there is enough space for the lifts foot print. Be sure to include space neccesary for platform.
Caution: Verify that the running clearance around the lift complies with
any codes for your area.
The horizontal gap between the edge of the platform and the upper landing must no less than 3/8"
and no greater than 3/4".
The horizontal gap between the guard panel and any wall or barrier must be no less than 2" and
no greater than 3".
Verify that sufficient head room exists above the lift. The lift will require 6' 8" of clearance above
the platform floor when the lift is at the upper landing.
Warning: The area between the floor where the lift is mounted and the top
landing must be covered by a smooth vertical fascia. This is to to eliminate any pinch
points between the platform and landing.
Connecting to Electricity
The lift will require a 115 VAC 20 amp grounded electrical circuit.
Depending on local codes, this connection may need to be routed in electrical conduit and hard-wired.
Warning: Do not ride on the lift until it has been anchored in place

Controller Harness Connections

High Voltage
Circuit Breaker
(AC unit only)
Low Voltage
Circuit Breaker
Platform
Safety Pan
Traveling Cable
Jumper
Phone Jack
Lower Landing
Connection
Interlock
.
Upper Landing
Upper & Lower
Interlock
Limit Switches
Upper & Lower
Bypass Switches
Call Sends
(Strikes only)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents