INNERSHIELD PRO & MAGNUM CLASSIC GUN
Connection to Lincoln Wirematic, Power MIG,
Hobart Series 2000 Feeders, or SP100T Type
Feeders.
Gun cable assemblies which were assembled with a K466-6,
K466-7 or K466-9 Connection Kit in the beginning of this
Installation Section will connect easily to a feeder.
1.
Check that the adapter and feeder outgoing guide, as well as the
drive rolls, are appropriate for the electrode size being used.
2. Fully push the brass connector end of the gun cable into the
outgoing side of the feeder wire drive. Secure the cable using
the hand screw on the wire feeder.
3. Insert the control cable plug from the feeder trigger circuit into
the mating socket on the gun cable feeder end handle.
Connection to a Tweco #5 adapted feeder.
1. Check that the drive roll(s) and feeder guide tubes are
appropriate for the electrode size being used.
2. Fully push the brass connector end of the gun cable into the
conductor block on the outgoing side of the feeder wire drive.
Secure the cable using the hand screw or set screw in the
conductor block.
3. Insert the round connector of the control cable into the mating
connector on the front of the wire feeder.
Connection to a Lincoln feeder for 3/32"
diameter wire
1. Check that the drive roll(s) and feeder guide tubes are
appropriate for the electrode size being used.
2. Fully push the brass connector end of the gun cable into the
conductor block on the outgoing side of the feeder wire drive.
Secure the cable using the hand screw or set screw in the
conductor block.
3. Insert the round connector of the control cable into the mating
connector on the front of the wire feeder.