Lincoln trained service technicians are authorized to perform these modifications. Explanation of the Problem Error 0092 occurs during filling procedure on Coolarc 26 product. Issue may occur in following setup: Source + 30m interconnection cable + feeder + torch. Verification of the Problem...
Page 2
Correction of the Problem 1. Unpack the product. 2. Unscrew 4 screws on left and right side of the cooler marked on below photos:...
Page 3
3. Slowly move back panel as it is shown in below photo and disconnect PE wire from the panel 4. Disassembled back panel with marked position of flow sensor:...
Page 4
5. Unscrew hex screw from flow sensor body 6. Setup flow sensor marker at the 26mm measured from bottom edge of flow sensor plastic body...
Page 5
7. Tighten the hex screw of flow sensor and check that is not moving. 8. Assembly back panel:...
Page 6
9. Connect the PE wire to back panel 10. Assembly back panel by 4 screws which were shown in point 2. 11. Repeat filling procedure.