Electrical Wire Diagram - Pit Boss RANCHER XL PB1000R1 Assembly And Operation Instructions Manual

Wood pellet grill & smoker
Table of Contents

Advertisement

The Digital Control Board system is an intricate and valuable piece of technology. For protection from power surges and electrical
shorts, consult the wire diagram below to ensure your power source is sufficient for the operation of the unit.
PB – ELECTRIC REQUIREMENTS
110-120V, 3.3AMP, 60HZ, 275W, 3-PRONG GROUNDED PLUG
NOTE: Electrical components, passed by product safety testing and
certification services, comply with a testing tolerance of ± 5-10 percent.
Y
Y Y
DRAFT FAN
120V, 50/60HZ,
0.1 AMP, 1 PHASE
INDEX
W : WHITE
K : BLACK
Y : YELLOW
S : SILVER
P : PURPLE
G : GREEN
R : RED

ELECTRICAL WIRE DIAGRAM

DIGITAL CONTROL BOARD
Y
P
Y
R
W
R R
AUGER MOTOR
& FEED SYSTEM
120V, 50/60HZ, 0.22 AMP,
2 RPM MOTOR
FUEL INPUT RATING: 1.12 KG/H (2.48 LB/H)
GRILL PROBE
MOLEX CONNECTOR
FAST-BLOW FUSE
5 AMP
GRILL PROBE
S
K
K
W
W
W
P
P
W
WW
W
W
IGNITER
GROUNDED
POWER CORD
VW-1, 105°C/221°F,
18-3 STANDARD CSA
G
GROUND
IGNITER ASSEMBLY /
HD CARTRIDGE HEATER
200W, 120V, 2.6 AMP
0.375" X 5.000"
BURN POT
HOPPER
ACCESS
PANEL
(4 screws)